Literature DB >> 36243894

A Modified Knotless Transscleral Intraocular Lens Fixation Technology for Congenital Ectopia Lentis.

Liyan Liu1, Xuepei Li1, Guangming Jin2, Danying Zheng3, Qianzhong Cao1, Zhangkai Lian1, Jieyi Wu1.   

Abstract

INTRODUCTION: This study aimed to compare modified knotless transscleral suture fixation of intraocular lens (IOL) with traditional transscleral suture fixation for adolescents and young patients with congenital ectopia lentis (CEL).
METHODS: This retrospective cohort study included 49 patients with CEL (60 eyes) who underwent surgery at the Zhongshan Ophthalmic Center. Improvements based on knotless Z-suture fixation technique were made to form a modified knotless method, in which thicker 8-0 polypropylene sutures were used, and double parallel scleral grooves were constructed behind the limbus instead of triangular lamellar scleral flaps to cover suture stitches. Modified knotless transscleral fixation of IOL was conducted on 30 eyes, and the other 30 eyes underwent traditional transscleral fixation surgery. Pre- and postoperative best-corrected visual acuity (BCVA), refractive error, astigmatism, other ocular parameters, and complications were statistically analyzed.
RESULTS: For patients in the modified knotless group, the mean cylindrical refractive error and astigmatism at 1 month and 3 months postoperative were lower (all P < 0.05), and the mean IOL tilt degree was smaller at 3 months postoperative (3.21° ± 2.13° vs. 5.65° ± 3.66°, P = 0.032). The incidence of suture exposure in the modified knotless group was also lower than in the controls (0 vs. 16.7%, P = 0.026). No group differences were observed in mean BCVA, spherical equivalent, or other ocular biometric parameters between groups.
CONCLUSION: Modified knotless technique was a valid method to achieve optimal IOL position and reduce postoperative astigmatism for adolescents and young patients with CEL. It effectively reduced the incidence of knot-related complications, greatly improved the postoperative comfort, and achieved aesthetic benefits.
© 2022. The Author(s).

Entities:  

Keywords:  Congenital ectopia lentis; IOL; Knotless; Transscleral suture fixation

Year:  2022        PMID: 36243894     DOI: 10.1007/s40123-022-00586-9

Source DB:  PubMed          Journal:  Ophthalmol Ther


  2 in total

Review 1.  The eye in the Marfan syndrome.

Authors:  I H Maumenee
Journal:  Trans Am Ophthalmol Soc       Date:  1981

2.  Corneal astigmatism correction with scleral flaps in trans-scleral suture-fixed posterior chamber lens implantation: a preliminary clinical observation.

Authors:  Li-Wei Ma; Dwight Xuan; Xiao-Yan Li; Jin-Song Zhang
Journal:  Int J Ophthalmol       Date:  2011-10-18       Impact factor: 1.779

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.