| Literature DB >> 36240191 |
Wattanan Watthanasathitnukun1, Savitree Pranpanus1, Chusana Petpichetchian1.
Abstract
OBJECTIVE: To evaluate certain two-dimensional (2D) ultrasound signs as predictors of massive peri-operative blood loss (PBL) in pregnant women with placenta previa suspicious of PAS disorder.Entities:
Mesh:
Year: 2022 PMID: 36240191 PMCID: PMC9565412 DOI: 10.1371/journal.pone.0276153
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.752
Fig 1Flow chart of study patients.
PAS: placenta accreta spectrum, PBL: perioperative blood loss.
Patient characteristics compared between the non-massive and massive perioperative blood loss (PBL) groups.
| Non-massive PBL | Massive PBL | ||
|---|---|---|---|
| n (%) | n (%) | ||
| 370 (71.3) | 146 (21.1) | ||
|
| 34 | 36 | 0.03 |
|
| 66 | 65 | 0.323 |
|
| <0.001 | ||
| 1 (%) | 72 (19.5) | 11 (7.5) | |
| ≥2 (%) | 298 (81.5) | 135 (92.5) | |
|
| <0.001 | ||
| 0, n (%) | 95 (25.7) | 13 (8.9) | |
| ≥1, n (%) | 275 (74.3) | 133 (91.1) | |
|
| < 0.001 | ||
| Null, n (%) | 186 (50.3) | 23 (15.8) | |
| 1, n (%) | 124 (33.5) | 66 (45.2) | |
| 2, n (%) | 45 (12.2) | 47 (32.2) | |
| ≥ 3, n (%) | 15 (4) | 10 (6.9) | |
|
| 0.874 | ||
| Elective cases, n (%) | 220 (59.5) | 85 (58.2) | |
| Emergency cases, n (%) | 150 (40.5) | 61 (41.8) | |
|
| 1000 | 4500 | <0.001 |
|
| |||
| PRC units, (median) | 0 | 5.5 (0, 6) | < 0.001 |
| FFP mL, (median) | 0 | 942.5 (500, 1611) | < 0.001 |
| PC units, (median) | 0 | 0 (0, 6) | < 0.001 |
|
| |||
| Hysterectomy, n (%) | 91 (24.6) | 122 (83.6) | < 0.001 |
| Four-vessel ligation, n (%) | 14 (3.8) | 6 (4.1) | 1.0 |
| B-lynch, n (%) | 2 (0.5) | 1 (0.7) | 1.0 |
|
| |||
| Bowel injury, n (%) | 1 (0.3) | 2 (1.4) | 0.194 |
| Bladder injury, n (%) | 5 (1.4) | 18 (12.3) | < 0.001 |
| Ureter injury, n (%) | 0 (0) | 5 (3.4) | 0.002 |
|
| 6 | 10 | < 0.001 |
|
| 18 (4.1) | 56 (84.8) | < 0.001 |
PBL—perioperative blood loss, PRC—packed red cells, FFP—fresh frozen plasma, PC—platelet concentration, ICU—intensive care unit
Ultrasound signs examined in the study as predictors of massive blood loss in PAS comparing the non-massive PBL and massive PBL groups.
| 2D Ultrasound sign | Non-massive PBL | Massive PBL | |
|---|---|---|---|
| n (%) | n (%) | ||
| 74 (42.3) | 101 (57.7) | ||
| Loss of clear zone | 61 (82.4) | 97 (96) | 0.006 |
| Abnormal placental lacunae | 55 (74.3) | 93 (92.1) | 0.003 |
| Bladder wall interruption | 40 (54.8) | 72 (71.3) | 0.037 |
| Myometrial thinning | 35 (47.9) | 70 (69.3) | 0.007 |
| Placental bulge | 18 (24.7) | 46 (45.5) | 0.008 |
| Focal exophytic mass | 0 (0) | 9 (8.9) | 0.011 |
| Uterovesical hypervascularity | 55 (75.3) | 91 (91) | 0.01 |
| Subplacental hypervascularity | 15 (20.5) | 41 (41) | 0.007 |
| Bridging vessels | 41 (56.2) | 58 (58) | 0.932 |
| Placental lacunae feeder vessels | 33 (45.2) | 72 (72) | <0.001 |
PAS—placenta accreta spectrum, 2D - two dimensional, PBL—perioperative blood loss
Ultrasound signs as predictors of massive blood loss in placenta previa without PAS.
| 2D Ultrasound sign | Non-massive PBL | Massive PBL | |
|---|---|---|---|
| n (%) | n (%) | ||
| 296 (86.8) | 45 (13.2) | ||
| Loss of clear zone | 64 (21.6) | 17 (37.8) | 0.029 |
| Abnormal placental lacunae | 36 (12.2) | 12 (26.7) | 0.017 |
| Bladder wall interruption, | 14 (4.7) | 5 (11.1) | 0.089 |
| Myometrial thinning | 9 (3) | 1 (2.2) | 1.0 |
| Placental bulge | 3 (1) | 1 (2.2) | 0.434 |
| Focal exophytic mass | 1 (0.3) | 0 (0) | 1.0 |
| Uterovesical hypervascularity | 24 (11.4) | 8 (21.6) | 0.108 |
| Subplacental hypervascularity | 6 (2.8) | 0 (0) | 0.596 |
| Bridging vessels | 11 (5.2) | 0 (0) | 0.378 |
| Placental lacunae feeder vessels | 8 (3.8) | 5 (13.5) | 0.03 |
2D - two dimensional, PBL—perioperative blood loss
Odds ratios of 2D ultrasound signs to predict massive PBL in the PAS group.
| 2D Ultrasound sign | Crude OR (95%CI) | Adjusted OR (95%CI) | |
|---|---|---|---|
| Loss of clear zone | 6.24 (3.83,10.17) | 1.96 (1.01,3.78) | 0.047 |
| Abnormal placental lacunae | 6.94 (4.37,11.03) | 1.86 (0.93,3.72) | 0.083 |
| Placental bulge | 6.52 (3.69,11.49) | 2.47 (1.23,4.97) | 0.01 |
| Focal exophytic mass | 19.83 (2.49,158.13) | 8.16 (0.89,74.47) | 0.024 |
| Uterovesical hypervascularity | 6.85 (4.34,10.8) | 2.19 (1.07,4.47) | 0.033 |
| Bridging vessels | 3.26 (2.07,5.13) | 0.47 (0.24,0.91) | 0.022 |
| Placental lacunae feeder vessels | 7.8 (4.85,12.54) | 2.38 (1.23,4.6) | 0.009 |
2D - two dimensional, PBL—perioperative blood loss, OR—odds ratio, PAS—placenta accreta spectrum, CI -confidence interval
Scores for each ultrasound sign to predict massive PBL in the PAS group.
| 2D Ultrasound sign | Score |
|---|---|
| Loss of clear zone | 0.5 |
| Abnormal placental lacunae | 0.5 |
| Placental bulge | 1.0 |
| Focal exophytic mass | 2.0 |
| Uterovesical hypervascularity | 1.0 |
| Placental lacunae feeder vessels | 1.0 |
| Bridging vessels | -1.0 |
PBL—perioperative blood loss, PAS—placenta accreta spectrum, 2D - two dimensional
Diagnostic accuracy of various cut points of the PAS scoring system to predict massive PBL.
| Cut point of score | Sensitivity | Specificity | FPR | FNR | PPV | NPV |
|---|---|---|---|---|---|---|
| ≥ 5.0 | 4% | 100% | 0% | 95% | 100% | 68% |
| ≥ 4.0 | 9% | 99% | 1% | 91% | 81% | 69% |
| ≥ 3.5 | 10% | 99% | 1% | 90% | 82% | 69% |
| ≥ 3.0 | 46% | 94% | 6% | 54% | 79% | 78% |
| ≥ 2.5 | 47% | 93% | 7% | 53% | 77% | 79% |
| ≥ 2.0 | 66% | 82% | 18% | 34% | 65% | 84% |
| ≥ 1.5 | 72% | 77% | 23% | 28% | 60% | 85% |
| ≥ 1.0 | 78% | 67% | 33% | 22% | 54% | 86% |
| ≥ 0.5 | 85% | 53% | 47% | 15% | 47% | 88% |
PAS—placenta accreta spectrum, PBL—perioperative blood loss, FPR—false positive rate, FNR—false negative rate, PPV—positive predictive value, NPV—negative predictive value
Fig 2Receiver operator curve of the scoring system to predict massive PBL in PAS disorders.
PAS: placenta accreta spectrum, PBL: perioperative blood loss.