Literature DB >> 3622553

Monte Carlo estimates of absorbed dose rate in various tissues and organs.

K Murase, M Kataoka, Y Yasuhara, M Ishine, M Kawamura, A Iio, K Hamamoto.   

Abstract

A computer program based on the Monte Carlo technique was developed for calculation of absorbed dose rate in various tissues and organs. The accuracy of the program was tested by reproducing Berger's values of the specific absorbed fractions for point isotropic sources in water, and a good agreement with those obtained by the moments method was found within an error of several percent. In comparing with experiment and other Monte Carlo results, good agreement was also obtained within the range of statistical error. The absorbed dose rate for an 123I, 124I, 125I, 126I and 99mTc point source and their specific dose constants in various tissues and organs were calculated using this program. This computer program has the mass energy absorption and attenuation coefficients for 69 tissues and organs as a database file, and can be extended to various radionuclides used in nuclear medicine by adding their nuclear data to the program.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3622553     DOI: 10.1007/bf00289020

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  13 in total

1.  Summary of current radiation dose estimates to humans from 123I, 124I, 125I, 126I, 130I, 131I, and 132I as sodium iodide.

Authors: 
Journal:  J Nucl Med       Date:  1975-09       Impact factor: 10.057

2.  Significance of radiocontaminants in 123I for dosimetry and scintillation camera imaging.

Authors:  G A Baker; D J Lum; E M Smith; H S Winchell
Journal:  J Nucl Med       Date:  1976-08       Impact factor: 10.057

3.  The dose in water surrounding point isotropic gamma-ray emitters.

Authors:  S Webb; R A Fox
Journal:  Br J Radiol       Date:  1979-06       Impact factor: 3.039

4.  The effective attenuation in water of the gamma rays of gold 198, iridium 192, cesium 137, radium 226, and cobalt 60.

Authors:  L L Meisberger; R J Keller; R J Shalek
Journal:  Radiology       Date:  1968-05       Impact factor: 11.105

5.  A Monte Carlo computer code to calculate radiation dose from syringes containing radioactive substances.

Authors:  S Sherbini; W Schadt; M Thomas; H S Alavijeh; A Tripathi
Journal:  J Nucl Med       Date:  1979-08       Impact factor: 10.057

6.  An analysis of the Z-dependence of photon and electron interactions.

Authors:  D R White
Journal:  Phys Med Biol       Date:  1977-03       Impact factor: 3.609

7.  Monte Carlo estimates of specific absorbed fractions for an I-125 point source in water.

Authors:  G S Burns; D E Raeside
Journal:  Med Phys       Date:  1983 Mar-Apr       Impact factor: 4.071

8.  Development of I-123-labeled amines for brain studies: localization of I-123 iodophenylalkyl amines in rat brain.

Authors:  H S Winchell; R M Baldwin; T H Lin
Journal:  J Nucl Med       Date:  1980-10       Impact factor: 10.057

9.  A tabulation of 4th order polynomial coefficients calculated to fit the photon interaction data of 69 ICRP Reference Man tissues.

Authors:  D R White; M Fitzgerald
Journal:  Health Phys       Date:  1977-12       Impact factor: 1.316

10.  [Clinical values of renal function study with 123I-Orthoiodohippurate (123I-OIH)].

Authors:  M Ishine; K Murase; M Koizumi; H Itoh; M Kawamura; S Inatsuki; A Iio; M Yokoyama; K Yamamoto; K Hamamoto
Journal:  Kaku Igaku       Date:  1982-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.