Literature DB >> 36205761

Thicker polyethylene inserts (≥ 13 mm) increase the risk for early failure after primary cruciate-retaining total knee arthroplasty (TKA): a single-centre study of 7643 TKAs.

Anni Rajamäki1, Mika Niemeläinen2, Mika Junnila2, Lari Lehtovirta2, Mari Karsikas2, Ville Ponkilainen3, Antti Eskelinen2.   

Abstract

PURPOSE: This study investigates whether thicker (PE) inserts lead to a greater risk for revision after TKA. The differences between the TKA designs of three manufacturers (NexGen, PFC Sigma, Triathlon) are also compared.
METHODS: A total of 7643 primary TKA surgeries were included. PE inserts were divided into two groups-"thick PE inserts" with a thickness of 13 mm (mm) or more and "standard PE inserts" with a thickness of less than 13 mm. Three cruciate-retaining (CR) TKA designs (NexGen, PFC Sigma, Triathlon) were included in the study. The differences in failure rates between groups were investigated using Kaplan-Meier survival curves and Cox regression model with hazard ratios (HR). Failure rates were investigated short-term (< 2 years) and long-term (the whole follow-up period). The TKA designs were analysed both together and separately.
RESULTS: During the whole follow-up period, there were 184 (2.4%) aseptic revisions. The thick PE insert group showed an increased risk for revision compared to the standard PE insert group in both short-term (< 2 years; HR 2.0, CI 1.3 to 3.2) and long term (> 2 years; HR 1.6, CI 1.1 to 2.3) follow-up. The highest revision rate was observed in patients who received the Triathlon TKA with a thicker PE insert (HR 2.6, CI 1.2 to 5.7).
CONCLUSION: The results indicate that thicker PE inserts are associated with increased risk for revision in primary TKA. Further research is required to ascertain whether more conformed PE inserts or constrained knee designs instead of thick CR inserts will ultimately lead to better clinical outcomes. LEVEL OF EVIDENCE: III.
© 2022. The Author(s).

Entities:  

Keywords:  Aseptic loosening; Cruciate-retaining implant; Instability; Polyethylene insert; Revision risk; Survival; TKA; Thickness

Year:  2022        PMID: 36205761     DOI: 10.1007/s00167-022-07189-8

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.114


  1 in total

Review 1.  Ligament balancing in total knee arthroplasty-Medial stabilizing technique.

Authors:  Shuichi Matsuda; Hiromu Ito
Journal:  Asia Pac J Sports Med Arthrosc Rehabil Technol       Date:  2015-08-07
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.