Literature DB >> 36203930

Relationship Between the Computed Tomographic Volumetry of the Eyeballs and Lacrimal Glands in a Nigerian Population.

Bukunmi Michael Idowu1, Stephen Olaoluwa Onigbinde2, Allen Li Chen3, Jordan B Hughes3, Oluwaseun Olaniyi Awe4,5, Joseph Adetola Adedigba3.   

Abstract

Aim: The aim of this article was to obtain measurements of the eyeballs/globes and lacrimal glands in normal subjects using cranial computed tomography (CT) scan. Understanding the normative approximations of these measurements could help in diagnosing and evaluating orbito-ocular pathologies. Materials and
Methods: This retrospective study examined 220 globes/eyeballs and 220 lacrimal glands of 110 consecutive participants. The eyeball volume was calculated using both the ellipsoid and spherical formulas, whereas lacrimal gland volume was approximated using the ellipsoid formula only.
Results: The mean age of the subjects was 51.18 ± 14.85 years and ranged from 22 to 85 years. The study population was 53.6% male (n = 59) and 46.3% female (n = 51). The mean volumes of all globes in this study were 5.82 ± 0.77 and 5.98 ± 0.75 cm3 using the ellipsoid and spherical formulae, respectively. The mean volume of all lacrimal glands was 0.42 ± 0.14 cm3 using the ellipsoid formula. The mean globe volumes using the ellipsoid and spherical formulae (6.02 ± 0.84 and 6.02 ± 0.84 cm3) in males were significantly larger than the corresponding mean globe volumes in females (5.59 ± 0.62 and 5.80 ± 0.65 cm3) (P < 0.0001 and P = 0.001, respectively). There was no significant difference between the lacrimal gland volumes of males (0.42 ± 0.14 cm3) and females (0.42 ± 0.14 cm3) (P = 0.84).
Conclusion: Males have larger eyeball/globe volumes than females. Eyeball and lacrimal gland volumes did not correlate significantly. Eyeball volume showed an inverse relationship with age. Age did not affect lacrimal gland volume. Copyright:
© 2022 Journal of the West African College of Surgeons.

Entities:  

Keywords:  Computed tomography; Nigeria; globe; lacrimal gland; normative dimensions

Year:  2022        PMID: 36203930      PMCID: PMC9531748          DOI: 10.4103/jwas.jwas_66_22

Source DB:  PubMed          Journal:  J West Afr Coll Surg        ISSN: 2276-6944


Introduction

The lacrimal gland is an eccrine gland that secretes tears and is located proximal to the superior and lateral rectus muscles.[1] The lacrimal gland is vital for ocular surface health, comfort, and maintenance of the optical quality of the cornea and by extension of the eye.[2] Globe and lacrimal gland measurements are important in the overall understanding of various pathologies in the orbit, particularly in the fields of ophthalmology and craniofacial surgery.[34] Various imaging modalities have been used in managing and monitoring various orbito-ocular pathologies. Magnetic resonance imaging (MRI) provides better soft tissue resolution, whereas computed tomography (CT) allows for better visualization of calcifications and bony changes.[15] Normative measurements of the globes and lacrimal glands of various ethnicities around the world have been documented.[6789101112] There is paucity of data on the globe and lacrimal gland CT measurements of Nigerians and other sub-Saharan Africans. There are few Nigerian studies that described globe volumes on cross-sectional imaging,[113141516] but only one on CT dimensions of the lacrimal gland. We could find no study in the English language literature that assessed the relationship between eyeball dimensions and lacrimal gland dimensions on CT. Therefore, the aim of this study was to evaluate the relationships between CT dimensions of the globes and lacrimal glands in a cosmopolitan Black African population.

Materials and Methods

This was a retrospective study of 110 consecutive cranial computed tomography (CT) scans (220 globes; 220 lacrimal glands) acquired at a radiodiagnostic centre in Lagos, Nigeria. The study protocol conformed to the ethical guidelines of the 1964 Declaration of Helsinki and its latest revisions in 2013. The electronic records of the patients were explored to extract their demographic characteristics, nationality, indications for imaging, and other relevant medical information. Craniofacial CT scans of patients aged 18 years and above with non-orbito-ocular indications for imaging were enrolled into the study. Scans were excluded if the patient was non-Nigerian, had poor image quality or had obvious structural variation(s), or abnormality in the anatomy of the globe such as aphakia or presence of an intraocular implant and other evident ocular, orbital, or lacrimal pathologies on CT. A Siemens 16-slice Somatom AR.T CT scanner (Siemens Healthineers AG, Erlangen, Germany) was used. The cranial CT scans were performed in an axial plane from the skull base to the vertex, with a slice thickness of 2.5 mm. The measurements were obtained directly on the computer control console of the CT scanner. We measured the anteroposterior (AP) and transverse (TS) diameters of the lacrimal glands on axial images [Figure 1], whereas the craniocaudal (CC) diameter was obtained on reformatted coronal images [Figure 2]. On the axial images, AP diameter of the lacrimal gland was measured from the most posterior edge of the gland to its most anterior edge. The TS diameter was measured perpendicular to the AP diameter, from the medial edge to the lateral edge of the gland at its widest location.[10] On the coronal images, the CC diameter was measured from the superior edge to the inferior edge of the lacrimal gland. The TS diameter of the lacrimal gland on coronal view was also determined in this image. All the measurements were obtained on any slice that demonstrated the maximal extent of the lacrimal gland.[10] The lacrimal gland volume was calculated using the ellipsoid formula as craniocaudal diameter (cm) × anteroposterior diameter (cm) × axial transverse diameter (cm) × 0.523 (mL). The lacrimal TS diameter on the coronal view was not included in the volume calculation, but was statistically compared to the axial TS diameter to determine any differences.
Figure 1

Axial CT of the lacrimal glands showing the anteroposterior diameters (lines A and C) and transverse diameters (lines B and D)

Figure 2

Coronal CT reformat of the lacrimal glands showing the craniocaudal diameters (lines M1 and M3) and coronal plane transverse diameters (lines M2 and M4)

Axial CT of the lacrimal glands showing the anteroposterior diameters (lines A and C) and transverse diameters (lines B and D) Coronal CT reformat of the lacrimal glands showing the craniocaudal diameters (lines M1 and M3) and coronal plane transverse diameters (lines M2 and M4) The globe measurements (inner margin to inner margin) were obtained from the axial scans taken at the level of the maximal thickness of the lens showing the optic nerve (mid-ocular axial section) [Figure 3]. The AP and TS diameters of the globes were measured on a mid-ocular axial section in which the axial size of the globes and lenses is maximal.[16] The AP diameter (axial length) of the globe was measured with the measuring calipers positioned at the level of the posterior (inner) corneal surface to the inner choroid interface. Images were magnified sufficiently enough to improve precision of placement of the digital measuring caliper without compromising image sharpness. The TS diameter (width) was the maximal distance from the nasal to the temporal ends of the globe. The ocular CC diameter was the maximum distance between the cranial and caudal ends of the globe on a reformatted mid-coronal image [Figure 4]. The TS diameter of the globe on coronal view was also determined in this image using an average of three measurements. The ocular TS diameter on the coronal view was not included in the volume calculation but was statistically compared with the axial TS diameter to determine any differences. One consultant radiologist performed all the CT measurements in the soft tissue window.
Figure 3

Axial CT of the eyeballs/globes at the level of the lens showing the anteroposterior diameters (lines A and C) and transverse diameters (lines B and D) of the eyeballs

Figure 4

Coronal CT reformat of the eyeballs/globes showing the craniocaudal diameters (lines M1 and M3) and coronal plane transverse diameters (lines M2 and M4) of the eyeballs

Axial CT of the eyeballs/globes at the level of the lens showing the anteroposterior diameters (lines A and C) and transverse diameters (lines B and D) of the eyeballs Coronal CT reformat of the eyeballs/globes showing the craniocaudal diameters (lines M1 and M3) and coronal plane transverse diameters (lines M2 and M4) of the eyeballs

Statistical analysis

Descriptive statistics were utilized to describe the demographics of the sample populations. Paired sample t-test was used to compare related groups means, and unpaired t-test was used to compare independent group means. One-way analysis of variance (ANOVA) with a Bonferroni post hoc test was used to analyse multiple groups. Pearson’s correlation was used to evaluate linear relationships between groups. Normality was always checked using the Shapiro–Wilk test; otherwise, the Mann–Whitney test and non-parametric methods were used to evaluate differences between groups. The globe volume was calculated using the two formulas: The ellipsoid formula[16] (cm3) is: Craniocaudal diameter (cm) x Anteroposterior diameter (cm) x Axial transverse diameter (cm) x 0.523. The spherical formula[14] (cm3) is where Lacrimal gland volume approximations were calculated using the following formula: Ellipsoid volume = Craniocaudal diameter (cm) × Anteroposterior axial diameter (cm) × Transverse axial diameter (cm) × 0.523.[16] Differences in volumes and linear dimensions between groups were considered statistically significant at a P-value of less than 0.05. The data were analysed using GraphPad Prism version 8.0 (GraphPad Software Inc., San Diego, CA, USA).

Results

The mean age of the enrolled subjects was 51.18 ± 14.85 years and ranged from 22 to 85 years. The study population consisted of 53.64% male (n = 59, mean age 50.34 ± 15.07 years) and 46.36% female (n = 51, mean age 52.16 ± 14.69 years). Both ellipsoid and spherical volume approximations were made for globes, whereas only ellipsoid volume was applied to the lacrimal glands. The mean ellipsoid volume of globes in this study was 5.82 ± 0.77 cm3, while the mean spherical volume was 5.98 ± 0.75 cm3. There was a significant difference between the ellipsoid volume and spherical volume approximations for globes (P < 0.0001). For all patients, mean right globe ellipsoid volume was 5.86 ± 0.82 cm3 and mean left globe volume was 5.79 ± 0.73 cm3; no significant difference existed between the left and right globes (P = 0.46). For the spherical formula, the mean right globe volume was 5.99 ± 0.73 cm3 and left globe volume was 5.97 ± 0.78 cm3, with no significant difference (P = 0.87). The mean globe ellipsoid volume for males (6.02 ± 0.84 cm3) was significantly larger than the mean globe ellipsoid volume for females (5.59 ± 0.62 cm3) (P < 0.0001). Likewise, the mean globe spherical volume for males (6.13 ± 0.80 cm3) was significantly larger than the mean globe spherical volume for females (5.80 ± 0.65 cm3) (P = 0.0012). These relationships are both depicted in Table 1. The average male globe ellipsoid volume was 7.69% larger than the volume of the average female globe, whereas the male globe was 5.69% larger using the sphere approximation.
Table 1

Lacrimal gland volume and eyeball volume by sex

SexCEEV (cm3)CSEV (cm3)EREV (cm3)ELEV (cm3)P-valueSREV (cm3)SLEV (cm3)P-valueRLGV (cm3)LLGV (cm3)P-value
Males (n=59)6.02 ± 0.846.13 ± 0.806.02 ± 0.885.96 ± 0.800.206.13 ± 0.736.13 ± 0.870.970.43 ± 0.130.41 ± 0.150.14
Females (n=51)5.59 ± 0.625.80 ± 0.655.62 ± 0.675.58 ± 0.590.425.82 ± 0.695.78 ± 0.610.410.42 ± 0.150.41 ± 0.140.38
P-value<0.00010.0012

CEEV: combined (both eyes) ellipsoid eyeball volume, CSEV: combined (both eyes) spherical eyeball volume, EREV: ellipsoid right eyeball volume, ELEV: ellipsoid left eyeball volume, SREV: spherical right eyeball volume, SLEV: spherical left eyeball volume, RLGV: right lacrimal gland volume, LLGV: left lacrimal gland volume

Lacrimal gland volume and eyeball volume by sex CEEV: combined (both eyes) ellipsoid eyeball volume, CSEV: combined (both eyes) spherical eyeball volume, EREV: ellipsoid right eyeball volume, ELEV: ellipsoid left eyeball volume, SREV: spherical right eyeball volume, SLEV: spherical left eyeball volume, RLGV: right lacrimal gland volume, LLGV: left lacrimal gland volume The volumes of the left and right globes were compared within sexes. For both the ellipsoid and spherical globe approximations, there was no significant difference between the left and right globes for both males and females, as depicted in Table 1. The mean ellipsoid volume of all lacrimal glands in this study was 0.42 ± 0.14 cm3. For all subjects, the mean volume of right lacrimal glands was 0.43 ± 0.14 cm3 and of left lacrimal glands was 0.41 ± 0.14 cm3 with no significant difference in volume (P = 0.33). There was no significant difference between the lacrimal gland volumes of males (0.42 ± 0.14 cm3) and females (0.42 ± 0.14 cm3) (P = 0.84). There was also no significant difference when comparing left and right lacrimal gland volumes for both males and females, as shown in Table 1. Next, we evaluated the linear diameters: AP, CC, and TS for globes and the lacrimal glands’ AP and CC diameters. The mean male globe CC diameter (2.23 ± 0.18 cm) was significantly larger than that for females (2.16 ± 0.13 cm) (P = 0.0006). The mean male globe TS diameters (2.33 ± 0.13 cm) were significantly larger than those for females (2.27 ± 0.11 cm) (P = 0.0005). The mean male globe AP diameters (2.20 ± 0.10 cm) were not significantly different from those for females (2.18 ± 0.09 cm) (P = 0.084). For the lacrimal gland linear parameters, mean male AP diameter (1.31 ± 0.16 cm) was not significantly different from the mean diameter for females (1.30 ± 0.16 cm) (P = 0.85). The mean male CC diameter (1.40 ± 0.17 cm) was also not significantly different from the mean female CC diameter (1.37 ± 0.19 cm) (P = 0.24). Our analysis showed no significant difference between male lacrimal gland mean TS axial diameter (0.43 ± 0.08 cm) and male lacrimal gland mean TS coronal diameter (0.43 ± 0.07 cm) (P = 0.80). However, there was a significant difference between female lacrimal gland mean TS axial diameters (0.44 ± 0.08 cm) and female lacrimal gland mean TS coronal diameters (0.41 ± 0.07 cm) (P = 0.0027). There was no significant difference found when all lacrimal gland mean TS axial diameters (0.43 ± 0.08 cm) were compared with all lacrimal gland mean TS coronal diameters (0.42 ± 0.07 cm). We divided the cohort into age groups and mean globe/lacrimal gland volumes associated with each group in Table 2. One-way ANOVA yielded significant differences among the age groups regarding globe volumes for both the ellipsoid and spherical approximations. There were no differences between age groups for lacrimal gland volumes. Table 3 compares the lacrimal gland dimensions in this study with those of some previous studies.
Table 2

Lacrimal gland and eyeball volume by age group

Age group (years)Number of subjectsEyeball ellipsoid volume (cm3)Eyeball sphere volume (cm3)Lacrimal gland volume (cm3)
20–29205.535.620.44
30–39206.386.300.39
40–49205.956.110.42
50–59205.926.240.42
60+305.535.640.42
P-value0.00220.00070.90
Table 3

Comparison of right and left lacrimal gland dimensions in different ethnicities

Index studyNawaz et al.[11]Bulbul[7]Danjem and Salaam[1]Lee et al.[23]Tamboli et al.[10]
Right lacrimal
 AL (mm)14.4113.5316.214.614.914.7
 AW (mm)4.314.204.14.14.15.1
 CL (mm)13.8015.4618.320.720.916.9
 CW (mm)4.303.994.12.93.65.2
Left lacrimal
 AL (mm)13.9013.3516.014.514.714.5
 AW (mm)4.304.054.04.14.34.8
 CL (mm)13.8015.2618.320.820.716.9
 CW (mm)4.203.864.13.03.85.2

AL: axial length (anteroposterior diameter on axial view), AW: axial width (transverse diameter on axial view), CL: coronal length (craniocaudal diameter on coronal view), CW: coronal width (transverse diameter on coronal view)

Lacrimal gland and eyeball volume by age group Comparison of right and left lacrimal gland dimensions in different ethnicities AL: axial length (anteroposterior diameter on axial view), AW: axial width (transverse diameter on axial view), CL: coronal length (craniocaudal diameter on coronal view), CW: coronal width (transverse diameter on coronal view) We evaluated the correlation of all globe volumes (ellipsoid/spherical approximations). Globe ellipsoid volume approximation demonstrated a weak but significant negative correlation (r = −0.23, P = 0.01). However, when the spherical volume approximation was used, the correlation became non-significant (r = −0.18, P = 0.06). Lacrimal gland volumes and age were correlated and yielded Pearson’s correlation r = −0.01658, P = 0.8635; hence, there was no significant correlation between lacrimal gland volumes and age. There was no statistically significant correlation between globe volumes and lacrimal gland volumes in this study. We correlated the globes’ AP, CC, TS diameters with age and lacrimal glands’ AP, CC diameters with age. Only the globes’ CC diameter showed a significant weak negative correlation with age (r = −0.21, P = 0.02).

Discussion

Globe volume is a crucial parameter in understanding the pathophysiology of many orbito-ocular diseases such as macrophthalmus, buphthalmus, and microphthalmus.[17] Quantifying the globe volume in a cohort of subjects with normal physiology can help in both medical and surgical management of orbito-ocular diseases.[16] Previous studies have used either the ellipsoid or spherical formula to calculate globe volume.[1416] The mean spherical globe volume in our study (5.98 ± 0.75 cm3) is marginally larger than the spherical globe volume of 5.28 cm3 reported by Igbinedion and Ogbeide,[14] but smaller than the spherical globe volume of 6.75 cm3 of Ibinaiye et al.[16] It is noteworthy that while the former used CT scan, the latter study used MRI. This study used both formulae to quantify globe volume to check how the two resulting volumes varied among male and female subjects. We found that the volume of male globes is significantly larger than the volume of female globes using both formulae. On average, the volume of male globes was larger than the volume of female globes by 7.69% and 5.69% using the ellipsoidal and spherical formulas, respectively. This appears consistent with a previous study that demonstrated that Iranian males had a larger globe volume than those of Iranian females.[3] However, there was no significant side-to-side difference between the right and left globe volumes in males and females using both formulae. Similar studies measuring globe volume of Nigerian eyes reported a larger volume of male eyes compared with female eyes, although the difference was not statistically significant.[1416] Male CC diameter being significantly longer than female CC diameter is another possible explanation for the larger globe volume found in males as any increased diameter of a three-dimensional structure will lead to increased volume. Male globe volumes being larger than female globe volumes could be due to males having a bigger body habitus than females, and this leads to male organs being bigger than the corresponding female organs.[1819] As the relationships of globe volume in inter-sex and intra-sex groups remain consistent using either the ellipsoid or spherical formula, this could mean that the two formulae are interchangeable when used to approximate globe volume. It is also noteworthy that while both formulas showed consistent relationships with age and gender, the spherical formula approximated a volume significantly larger than the ellipsoid volume. Igbinedion and Ogbeide[14] preferred the spherical formula because they believed that it reduced the likely margin of error associated with the ellipsoid formula. It is also known that the globe is not a perfect sphere. As there is a paucity of literature comparing these two formulas in the same study, further studies using globe models of known volumes will help to determine which of the two formulas approximates globe volume better. Interestingly, Pearson’s linear regression analysis comparing globe volume with age showed a weak negative, albeit significant, correlation. Igbinedion and Ogbeide[14] and Hahn and Chu[20] both reported decline in globe volume from 50 and 30 years, respectively. A possible explanation for this finding could be that the structural proteins in the globe lose their integrity with age, thus resulting in a mild reduction in globe volume over time.[20] Ageing, through multiple mechanisms, leads to enhanced degradation of extracellular matrix proteins such as elastin and collagen, thus resulting in decreased structural integrity of these proteins.[21] Furthermore, choroidal volume which includes vasculature, stroma, and connective tissue has been shown to decrease with age.[22] The cumulative physiological effects of ageing may contribute to the overall loss of globe size over time. The CC diameter was longer in males compared with females and decreased with increasing age. The globe axial TS diameter was longer in males than in females. This finding is congruent with a study by Bulbul[7] who found statistically significant differences among males and females regarding globe axial length. While Bulbul[7] found a significant correlation between age and globe axial diameter, this study found no correlation between age and globe axial diameter. This difference could be due to the higher statistical power of our sample population. The globes’ AP diameter was not significantly correlated with age or gender. Lacrimal gland volumes reported by prior studies have been generated using tracings and not mathematical formulas, which might provide a more exact approximation.[819] This is the first study, to the best of our knowledge, to quantify lacrimal gland volumes using the ellipsoid formula. Studies using the freehand pencil tracing method found a right lacrimal gland volume of 0.696 ± 0.261 cm3 and left lacrimal gland volume of 0.649 ± 0.231 cm3 in a Caucasian population in the USA and 0.617 ± 0.210 cm3 (right lacrimal) and 0.597 ± 0.197 cm3 (left lacrimal) in Turkey.[79] These values are higher than the mean lacrimal gland volume (0.42 ± 0.14 cm3) of all subjects in this study using the ellipsoid formula. Unlike globe volume, sex had no correlation with lacrimal gland volume as our analysis showed that there is no difference between the lacrimal volumes of males and females. This finding is also supported by the results in a study describing the CT-measured lacrimal gland volumes using freehand pencil tracing in a Caucasian population in USA.[9] We also found that age had no correlation with lacrimal gland volume. Studies among Caucasian and Korean populations using freehand pencil tracing have shown that an increase in age correlated with a decrease in lacrimal gland volume.[91023] Obata et al.[24] speculated that the decreased lacrimal gland size with age is probably due to periductal fibrosis resulting from decreased tear outflow as people age. Our study did not agree with this finding in the other studies. We suspect that the discrepancy could be due to different methods used to approximate the lacrimal gland volumes. Comparing the approximation formula with the tracing method, there is a possibility that these two methods are interchangeable among males and females but yield different approximations between age groups. The statistical power of our cohort could have affected our finding on the relationship between age and lacrimal gland volume. Also, the lacrimal gland linear variables (AP and CC diameter) were not significant with age and gender, which also explain the similar pattern seen with lacrimal volume mentioned earlier. Regarding the two methods of lacrimal volume approximations, there need to be more studies that explore if the formula method is more accurate, considering that the formula method might eliminate the potential human error associated with the freehand pencil tracing method. Although we found no statistically significant correlation between globe volume and lacrimal gland volume, we could not compare this observation to previous studies because the relationship between globe volume and lacrimal gland volume is currently understudied in the literature. Further exploration of this relationship would be needed to properly ascertain the relationship between globe volumes and lacrimal gland volumes. However, Tenzel et al.,[25] using MRI, reported that lacrimal gland volume (generated using OsiriX software) correlated with orbital volume, though the correlation coefficient was not stated. The lacrimal gland TS axial diameter and lacrimal gland TS coronal diameter are the same measurements from two viewpoints (axial and coronal). When controlling for sex, there was no significant difference between the male lacrimal gland TS axial diameters and lacrimal gland TS coronal diameters, but there was a significant difference between these dimensions among female subjects. This difference disappears when all TS axial diameters were compared with all TS coronal diameters in this patient population. This lack of significant difference among all subjects in this cohort could mean that either axial TS diameter or coronal TS diameter would suffice for lacrimal gland volume calculations using the ellipsoid formula. Since this is probably the first study to explore the interchangeability of these two measurements in the ellipsoid formula, more studies with higher statistical power are needed to ascertain if both measurements are statistically similar. Comparing our linear dimensions with other populations around the world, the reported lacrimal gland axial diameter in Caucasians (0.48 cm on the left and 0.51 cm on the right)[9] is higher than the axial diameter in this study (0.43 ± 0.082 cm), whereas the reported Korean (right = 0.41 cm, left = 0.43 cm)[23] and Pakistani (right = 0.42 cm, left = 0.41 cm)[11] axial diameters are similar to ours. The coronal diameter of the lacrimal gland in our study (0.42 ± 0.068 cm) was lower than that reported in a similar study of Caucasians (0.52 cm bilaterally)[9] but higher than that of Korean (right = 0.36 cm; left = 0.38 cm)[23] and Pakistani (right = 0.399 cm; left = 0.386 cm)[11] studies. These findings suggest that lacrimal gland axial and coronal diameters may be different among various ethnicities and geographical locations around the world.

Limitations

The limitations of this study include the following: first, prior clinical examination of the eyes (refractive errors causing posterior staphyloma can affect ocular dimensions) was impossible in a retrospective study. Secondly, the lacrimal gland has a density similar to the surrounding orbital structures which sometimes made it challenging to measure it on CT—such images were excluded. Thirdly, a 16-slice CT scanner was used for this study; a much higher slice spiral scanner might perhaps provide more detail for better assessment.

Conclusion

This study generated normative data that can be a reference for ophthalmologists, craniofacial surgeons, and other physicians. There was no significant correlation between globe volume and lacrimal gland volume. Male globes were larger than female globes. While age correlated inversely with globe volume, there was no correlation between age and lacrimal gland volume.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

Authors’ contribution

BMI: Conception, design, literature search, data acquisition, data analysis, statistical analysis, manuscript preparation, manuscript editing, manuscript review, approval of final draft, guarantor. SOO: Statistical analysis, manuscript review, approval of final draft, guarantor. ALC: Manuscript editing, manuscript review, approval of final draft. JBH: Manuscript editing, manuscript review, approval of final draft. OOA: Manuscript editing, manuscript review, approval of final draft. JAA: Design, literature search, manuscript preparation, manuscript editing, manuscript review, approval of final draft.
  18 in total

Review 1.  Gross characteristics of normal human lacrimal glands.

Authors:  Mortimer Lorber
Journal:  Ocul Surf       Date:  2007-01       Impact factor: 5.033

2.  Measurement of normal ocular volume by the use of computed tomography.

Authors:  B O Igbinedion; O U Ogbeide
Journal:  Niger J Clin Pract       Date:  2013 Jul-Sep       Impact factor: 0.968

Review 3.  Lacrimal gland masses.

Authors:  Yiming Gao; Gul Moonis; Mary E Cunnane; Ronald L Eisenberg
Journal:  AJR Am J Roentgenol       Date:  2013-09       Impact factor: 3.959

4.  Evaluation of Lacrimal Gland Dimensions and Volume in Turkish Population with Computed Tomography.

Authors:  Erdogan Bulbul; Alper Yazici; Bahar Yanik; Hasmet Yazici; Gulen Demirpolat
Journal:  J Clin Diagn Res       Date:  2016-02-01

5.  Ocular volume measured by CT scans.

Authors:  F J Hahn; W K Chu
Journal:  Neuroradiology       Date:  1984       Impact factor: 2.804

6.  Normal Lacrimal Gland Volumes by Magnetic Resonance Imaging and the Relationship of Lacrimal Gland Volume to Orbital Size.

Authors:  Phillip A Tenzel; Diana Moffa; Alexander P Decilveo; Harsha S Reddy
Journal:  J Craniofac Surg       Date:  2019 Nov-Dec       Impact factor: 1.046

7.  Computed tomographic dimensions of the lacrimal gland in healthy orbits.

Authors:  Joon Sik Lee; Hwa Lee; Jung Wan Kim; Minwook Chang; Minsoo Park; Sehyun Baek
Journal:  J Craniofac Surg       Date:  2013-05       Impact factor: 1.046

8.  Histopathologic study of human lacrimal gland. Statistical analysis with special reference to aging.

Authors:  H Obata; S Yamamoto; H Horiuchi; R Machinami
Journal:  Ophthalmology       Date:  1995-04       Impact factor: 12.079

Review 9.  The Mechanobiology of Aging.

Authors:  Jude M Phillip; Ivie Aifuwa; Jeremy Walston; Denis Wirtz
Journal:  Annu Rev Biomed Eng       Date:  2015       Impact factor: 9.590

10.  Computed tomographic measurements of orbital entrance dimensions in relation to age and gender in a sample of healthy Iranian population.

Authors:  Zoha Khademi; Parvindokht Bayat
Journal:  J Curr Ophthalmol       Date:  2016-04-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.