Literature DB >> 36197500

A standardized method of measuring screw breach on postoperative computed tomography scans following percutaneous fixation of the posterior pelvic ring.

Michael M Hadeed1, Katya E Strage1, Cyril Mauffrey1, Austin Heare1, Joshua A Parry2.   

Abstract

PURPOSE: To assess the reliability of a standardized measurement of screw breach on postoperative computed tomography (CT) scans following percutaneous fixation of the posterior pelvic ring.
METHODS: Three orthopedic trauma surgeons independently utilized a standardized method of measuring posterior pelvic ring screw breaches on post-operative CT scan images. Breaches were measured as a continuous variable on sagittal images reformatted to be perpendicular to the screw on axial images. The inter-rater and intra-rater reliability of screw breach distance measurements was assessed.
RESULTS: Measurements were performed on 42 screws in 20 patients. Screw types included S1-iliosacral (IS) (n = 16), S1-transsacral (TS) (n = 8), S2-IS (n = 2), and S2-TS (n = 16). Patients with varying degrees of screw breaches were chosen to test measurements across breach severities, including 0 mm (n = 10), ≤ 2 mm (n = 12), > 2 to 4 mm (n = 11), and > 4 mm (n = 9). The mean difference and 95% confidence interval (CI) between screw breach measurements between the three surgeons was - 0.13 mm (CI - 0.48 to 0.20), 0.05 mm (CI - 0.6 to 0.7), and 0.18 mm (CI - 0.47 to 0.85), respectively. The inter-rater reliability of the measurements was considered excellent (intraclass correlation coefficient (ICC), 0.93). The mean intra-rater reliability for the observers was considered good (ICC 88.5, CI 82 to 95).
CONCLUSIONS: This simple standardized method of measuring screw breaches had excellent inter-rater reliability and would support comparisons of screw breach severity across studies. LEVEL OF EVIDENCE: Level III.
© 2022. The Author(s), under exclusive licence to Springer-Verlag France SAS, part of Springer Nature.

Entities:  

Keywords:  Pelvic ring injury; Percutaneous acetabulum; Percutaneous pelvic ring; Sacroiliac screw; Screw breach; Transsacral screw

Year:  2022        PMID: 36197500     DOI: 10.1007/s00590-022-03399-5

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  12 in total

1.  Part 1: Outcome of Posterior Pelvic Ring Injuries and Associated Prognostic Factors - A Five-Year Retrospective Study of One Hundred and Sixty Five Operated Cases with Closed Reduction and Percutaneous Fixation.

Authors:  Mehdi Boudissa; A Roudet; V Fumat; S Ruatti; G Kerschbaumer; M Milaire; P Merloz; J Tonetti
Journal:  Int Orthop       Date:  2020-04-23       Impact factor: 3.075

2.  Percutaneous iliosacral screw fixation in S1 and S2 for posterior pelvic ring injuries: technique and perioperative complications.

Authors:  Georg Osterhoff; Christian Ossendorf; Guido A Wanner; Hans-Peter Simmen; Clément M L Werner
Journal:  Arch Orthop Trauma Surg       Date:  2010-12-28       Impact factor: 3.067

3.  Multidimensional Pelvic Fluoroscopy: A New and Novel Technique for Assessing Safety and Accuracy of Percutaneous Iliosacral Screw Fixation.

Authors:  James Shaw; Joshua Gary; Catherine Ambrose; Milton Chip Routt
Journal:  J Orthop Trauma       Date:  2020-11       Impact factor: 2.512

Review 4.  Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis.

Authors:  Jörn Zwingmann; Oliver Hauschild; Gerrit Bode; Norbert P Südkamp; Hagen Schmal
Journal:  Arch Orthop Trauma Surg       Date:  2013-06-08       Impact factor: 3.067

5.  Iliosacral screw fixation: early complications of the percutaneous technique.

Authors:  M L Routt; P T Simonian; W J Mills
Journal:  J Orthop Trauma       Date:  1997-11       Impact factor: 2.512

6.  Fluoroscopic positioning of sacroiliac screws in 88 patients.

Authors:  Eric W van den Bosch; C Marieke A van Zwienen; Arie B van Vugt
Journal:  J Trauma       Date:  2002-07

7.  Closed reduction and iliosacral percutaneous fixation of unstable pelvic ring fractures.

Authors:  Daniel Schweitzer; Alejandro Zylberberg; Marcelo Córdova; Jaime Gonzalez
Journal:  Injury       Date:  2008-07-14       Impact factor: 2.586

8.  Assessment of pelvic injuries treated with ilio-sacral screws: injury severity and accuracy of screw positioning.

Authors:  Miguel Pishnamaz; Thomas Dienstknecht; Barbara Hoppe; Christina Garving; Henning Lange; Frank Hildebrand; Philipp Kobbe; Hans-Christoph Pape
Journal:  Int Orthop       Date:  2015-08-11       Impact factor: 3.075

9.  Three-dimensional navigation is more accurate than two-dimensional navigation or conventional fluoroscopy for percutaneous sacroiliac screw fixation in the dysmorphic sacrum: a randomized multicenter study.

Authors:  Amir Matityahu; David Kahler; Christian Krettek; Ulrich Stöckle; Paul Alfred Grutzner; Peter Messmer; Jan Ljungqvist; Florian Gebhard
Journal:  J Orthop Trauma       Date:  2014-12       Impact factor: 2.512

10.  Corridor-diameter-dependent angular tolerance for safe transiliosacral screw placement: an anatomic study of 433 pelves.

Authors:  D Alex McLaren; Gennadiy A Busel; Harsh R Parikh; Arthur Only; Jason Patterson; Brandon T Gaston; Ryan McLemore; Brian Cunningham
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-03-01