Literature DB >> 3619167

Self-adhesive monitor/defibrillation pads improve prehospital defibrillation success.

K R Stults, D D Brown, F Cooley, R E Kerber.   

Abstract

We compared self-adhesive, dual-function monitor/defibrillation electrode pads to standard chest monitoring leads and hand-held electrode paddles in the management of prehospital ventricular fibrillation in a single urban paramedic service. Shocks were delivered more quickly following paramedic arrival with self-adhesive pads than with hand-held paddles (1.6 vs 2.5 min; P less than .001). Ventricular fibrillation was terminated more frequently when shocks were delivered using the self-adhesive pads (55 of 58 patients, 95%) than when shocks were delivered using hand-held paddles (49 of 69 patients, 71%; P less than .005). Initial shocks delivered with self-adhesive pads were especially effective, converting 40 of 58 (69%) patients to an organized rhythm on the first or second shock; this was true of only 24 of 69 (35%) patients shocked with hand-held paddles (P less than .001). Patient survival to hospital admission improved when self-adhesive pads were used: 30 of the 58 (52%) patients shocked with self-adhesive pads achieved hospital admission, while only 21 of 69 patients (30%; P less than .025) survived to admission when hand-held paddles were used. In addition, electrical artifact that interfered with accurate rhythm interpretation was far more prevalent when standard monitoring electrodes were used, including artifact that resulted in inappropriate shock delivery (23% of patients monitored with standard electrodes vs 3% of patients monitored with self-adhesive pads; P less than .005). Self-adhesive monitor/defibrillation pads are superior to standard monitoring leads and hand-held electrode paddles in the management of prehospital ventricular fibrillation.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3619167     DOI: 10.1016/s0196-0644(87)80525-5

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  4 in total

1.  Part 10: Pediatric basic and advanced life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations.

Authors:  Monica E Kleinman; Allan R de Caen; Leon Chameides; Dianne L Atkins; Robert A Berg; Marc D Berg; Farhan Bhanji; Dominique Biarent; Robert Bingham; Ashraf H Coovadia; Mary Fran Hazinski; Robert W Hickey; Vinay M Nadkarni; Amelia G Reis; Antonio Rodriguez-Nunez; James Tibballs; Arno L Zaritsky; David Zideman
Journal:  Circulation       Date:  2010-10-19       Impact factor: 29.690

2.  Pediatric basic and advanced life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations.

Authors:  Monica E Kleinman; Allan R de Caen; Leon Chameides; Dianne L Atkins; Robert A Berg; Marc D Berg; Farhan Bhanji; Dominique Biarent; Robert Bingham; Ashraf H Coovadia; Mary Fran Hazinski; Robert W Hickey; Vinay M Nadkarni; Amelia G Reis; Antonio Rodriguez-Nunez; James Tibballs; Arno L Zaritsky; David Zideman
Journal:  Pediatrics       Date:  2010-10-18       Impact factor: 7.124

3.  Barriers in the implementation of the Resuscitation Guidelines: European survey of defibrillation techniques.

Authors:  Paweł Krawczyk; Andrzej A Kononowicz; Janusz Andres
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2016-03-11       Impact factor: 2.953

4.  The Crash Course: A Shocking Introduction to Defibrillation.

Authors:  Naima Maqsood; Isaac Whitman; Erin R Camac
Journal:  ATS Sch       Date:  2022-06-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.