Literature DB >> 3618768

Cl(-)-selective microelectrodes: sensitivity to anionic Cl- transport inhibitors.

A C Chao, W M Armstrong.   

Abstract

Cl(-)-selective microelectrodes, containing Corning code 477315 or 477913 liquid ion exchangers, are often used to measure extra- and intracellular Cl- activities in the presence of Cl- transport inhibitors such as furosemide, bumetanide, and the stilbene sulfonic acid derivative 4-acetamido-4'-isothiocyanostilbene-2,2'-disulfonic acid (SITS). Because these inhibitors are anions in the physiological pH range and have relatively high lipid solubilities, they would be expected to interfere with the response to Cl- of these microelectrodes. Preliminary reports have confirmed this expectation. We examined the effect of furosemide, bumetanide, and SITS on the Cl(-)-selective barrels of double-barreled microelectrodes containing Corning code 477315 liquid anion exchanger and suitable for impaling small cells (e.g., epithelial cells). The results showed that at pH 8.2 in pure solutions of furosemide and bumetanide, these microelectrodes gave linear responses to the logarithm of furosemide or bumetanide concentrations ranging from 1 X 10(-2) to 1 X 10(-4) M. In the physiological pH range both these inhibitors (in concentrations of 0.1 mM) interfered significantly with the response of the microelectrodes to Cl- (in concentrations ranging from 100 to 1 mM). Calculated electrode sensitivities, relative to Cl-, were approximately 150 for both these compounds. Microelectrodes of this type appeared to be approximately 1,000 times as sensitive toward SITS as they were toward Cl-.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3618768     DOI: 10.1152/ajpcell.1987.253.2.C343

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  6 in total

1.  The effect of loop diuretics on Cl- transport in smooth muscle of the guinea-pig vas deferens and taenia from the caecum.

Authors:  C C Aickin; A F Brading
Journal:  J Physiol       Date:  1990-02       Impact factor: 5.182

2.  Intracellular chloride and the mechanism for its accumulation in rat lumbrical muscle.

Authors:  C C Aickin; W J Betz; G L Harris
Journal:  J Physiol       Date:  1989-04       Impact factor: 5.182

3.  Intracellular chloride activity in glial cells of the leech central nervous system.

Authors:  K Ballanyi; W R Schlue
Journal:  J Physiol       Date:  1990-01       Impact factor: 5.182

4.  Fluorescence measurement of chloride transport in monolayer cultured cells. Mechanisms of chloride transport in fibroblasts.

Authors:  A C Chao; J A Dix; M C Sellers; A S Verkman
Journal:  Biophys J       Date:  1989-12       Impact factor: 4.033

Review 5.  Role of physiological ClC-1 Cl- ion channel regulation for the excitability and function of working skeletal muscle.

Authors:  Thomas Holm Pedersen; Anders Riisager; Frank Vincenzo de Paoli; Tsung-Yu Chen; Ole Bækgaard Nielsen
Journal:  J Gen Physiol       Date:  2016-04       Impact factor: 4.086

6.  A highly-selective chloride microelectrode based on a mercuracarborand anion carrier.

Authors:  Marino DiFranco; Marbella Quinonez; Rafal M Dziedzic; Alexander M Spokoyny; Stephen C Cannon
Journal:  Sci Rep       Date:  2019-12-11       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.