| Literature DB >> 36180025 |
Chien-Chih Chou1,2,3,4, Po-Jen Shih5, Chun-Yuan Wang2, Tzuu-Shuh Jou1,6, Jun-Peng Chen7, I-Jong Wang1,8,9.
Abstract
Purpose: To characterize the corneal biomechanical properties of primary angle closure glaucoma (PACG) and to investigate the diagnostic performance of combining corneal biomechanical parameters and anterior segment parameters in detecting PACG.Entities:
Mesh:
Year: 2022 PMID: 36180025 PMCID: PMC9547358 DOI: 10.1167/tvst.11.10.7
Source DB: PubMed Journal: Transl Vis Sci Technol ISSN: 2164-2591 Impact factor: 3.048
Demographic and Ocular Characteristics of Participants
| Control (n = 79) | PACG (n = 81) |
| |
|---|---|---|---|
| Age (years) | 64.0 (56.0, 70.0) | 70.0 (67.5, 76.0) | <0.001 |
| Sex | 0.001 | ||
| Male, no. (%) | 39 (49.4%) | 18 (22.2%) | |
| Female, no. (%) | 40 (50.6%) | 63 (77.8%) | |
| Average RNFL (μm) | 94.00 (89.00, 99.00) | 92.00 (80.50, 99.00) | 0.061 |
| MD (dB) | −1.16 (−2.13, −0.14) | −3.00 (−6.06, −1.17) | <0.001 |
| PSD (dB) | 1.69 (1.39, 2.11) | 2.05 (1.59, 3.84) | <0.001 |
| CCT (µm) | 559.00 (540.00, 590.00) | 541.00 (518.50, 559.00) | <0.001 |
| IOP (mm Hg) | 16.50 (14.50, 19.00) | 15.50 (13.50, 17.50) | 0.006 |
| bIOP (mmHg) | 14.60 (12.90, 16.70) | 14.00 (12.05, 15.35) | 0.061 |
| ACV (mm3) | 123.00 (101.50, 151.25) | 77.00 (55.75, 90.25) | <0.001 |
bIOP, biomechanically corrected intraocular pressure; MD, mean deviation; PSD, pattern standard deviation; RNFL, retinal nerve fiber layer thickness.
Data are presented as median (interquartile range) unless stated otherwise. Mann-Whitney U test was used.
χ2 test was used.
Corneal Biomechanical Parameters Obtained Using Corvis ST
| Control (n = 79) | PACG (n = 81) |
| |
|---|---|---|---|
| CBI | 0.08 (0.03, 0.18) | 0.33 (0.14, 0.60) | <0.001 |
| CBiF | 6.61 (6.39, 6.88) | 6.20 (5.93, 6.48) | <0.001 |
| E-stage | 0.00 (0.00, 0.20) | 0.50 (0.00, 1.00) | <0.001 |
Data are presented as median (interquartile range). Mann-Whitney U test was used.
Logistic Regression Analyses for Predicting Primary Angle Closure Glaucoma
| Univariable | Multivariable | |||
|---|---|---|---|---|
| Measurement | Odds Ratio (95% CI) |
| Odds Ratio (95% CI) |
|
| Age (years) | 1.120 (1.070–1.173) | <0.001 | 1.067 (0.982–1.159) | 0.126 |
| Sex (Male) | 0.293 (0.148–0.581) | <0.001 | 0.350 (0.100–1.223) | 0.100 |
| CCT (µm) | 0.980 (0.970–0.990) | <0.001 | 0.996 (0.974–1.018) | 0.700 |
| IOP (mm Hg) | 0.898 (0.814–0.991) | 0.032 | 0.959 (0.796–1.154) | 0.656 |
| ACV (mm3) | 0.947 (0.931–0.964) | <0.001 | 0.950 (0.929–0.971) | <0.001 |
| CBiF | 0.021 (0.006–0.079) | <0.001 | 0.029 (0.003–0.266) | 0.002 |
Receiver Operating Characteristic Analyses
| Variables | AUC | (95% CI) |
| Optimal Cutoff | Sensitivity | Specificity |
|---|---|---|---|---|---|---|
| ACV (mm3) | 0.878 | (0.823–0.928) | <0.001 | >96 | 86.84% | 80.26% |
| CBiF | 0.799 | (0.726–0.860) | <0.001 | >6.224 | 51.32% | 97.37% |
| ACV + CBiF | 0.934 | (0.882–0.968) | <0.001 | 92.11% | 80.26% |
The formula used for the multiparameter classifier comprising CBiF and ACV was Ln(p/1 − p) = 32.117 − 0.057*ACV − 4.119*CBiF.
Figure.Receiver operating characteristic curve demonstrated the performance of ACV, CBiF, and ACV + CBiF in discriminating between patients with primary angle closure glaucoma and controls. ACV + CBiF exhibited the highest area under the receiver operating characteristic curve (0.934; 95% CI, 0.882–0.968) compared with ACV alone (0.878; 95% CI, 0.823–0.928) or CBiF alone (0.799; 95% CI, 0.726–0.860). ACV + CBiF had significantly higher discriminatory ability than that of ACV alone (DeLong test, P = 0.004) and the CBiF alone (DeLong test, P < 0.001).