Volume, flow, and timing of each breath during positive-pressure breathing in man.

B Bishop, J Hirsch, M Thursby.   

Abstract

This study is a breath-by-breath analysis of the effects of 5, 10, and 15 cmH2O positive-pressure breathing (PPB) on man's steady-state breathing pattern. Inspiratory (TI), expiratory (TE), and cycle (TT) durations, tidal volumes (VT), minute ventilation (VE), mean inspiratory flow rate (VT/TI), and mean expiratory flow rate (VT/TE) were determined from pneumotachograph and Wedge spirometer recordings before and during steady states on PPB. End-tidal CO2 was continuously recorded. Seventeen adults, seated in a full body-box, breathed quietly for 8 min through a mouthpiece on a bag-in-box. Pressure in the body-box was lowered to the desired level prior to 4 min of stress. On all pressure levels, end-expiratory volume, VT, VE, VT/TI, and VT/TE increased; end-tidal CO2, TE, and TT decreased with no consistent change in TI. Calculated alveolar ventilations indicated that the increases in VE were true hyperventilations. Each individual increased VE by using a unique combination of VT, TI, and TE. End-expiratory volume increased less and expiratory flow increased more than would occur passively. Hence, it is concluded that active reflexes account for the resistance of the systems to the passive distention, the facilitation of expiratory flow, and the shortening of TE.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 361664     DOI: 10.1152/jappl.1978.45.4.495

Source DB:  PubMed          Journal:  J Appl Physiol Respir Environ Exerc Physiol        ISSN: 0161-7567


  3 in total

1.  Effect of Continuous Positive Airway Pressure on Airway Reactivity in Asthma. A Randomized, Sham-controlled Clinical Trial.

Authors:  Janet T Holbrook; Elizabeth A Sugar; Robert H Brown; Lea T Drye; Charles G Irvin; Alan R Schwartz; Robert S Tepper; Robert A Wise; Razan Z Yasin; Michael F Busk
Journal:  Ann Am Thorac Soc       Date:  2016-11

2.  Aerosol kinetics and bronchodilator efficacy during continuous positive airway pressure delivered by face mask.

Authors:  S N Parkes; A D Bersten
Journal:  Thorax       Date:  1997-02       Impact factor: 9.139

3.  Increase in lung volume originated by extrinsic PEEP in patients with auto-PEEP. The role of static lung compliance.

Authors:  E Fernández Mondéjar; G Vazquez Mata; P Navarrete Navarro; R Rivera Fernández; J M Torres Ruiz; E Carazo
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.