Literature DB >> 36163028

Publisher Correction to: Discomfort improvement for critically ill patients using electronic relaxation devices: results of the cross‑over randomized controlled trial E‑CHOISIR (Electronic‑CHOIce of a System for Intensive care Relaxation).

Lili Merliot-Gailhoustet1, Chloé Raimbert1, Océane Garnier1, Julie Carr1, Audrey De Jong1, Nicolas Molinari2, Samir Jaber1, Gerald Chanques3.   

Abstract

Entities:  

Year:  2022        PMID: 36163028      PMCID: PMC9513888          DOI: 10.1186/s13054-022-04169-9

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   19.334


× No keyword cloud information.

Publisher Correction to: Critical Care (2022) 26:263 https://doi.org/10.1186/s13054-022-04136-4

Following publication of the original article [1], the authors identified errors in Table 2, affiliation 1 and the e-mail address of the corresponding author. In Table 2 certain values were not correctly indicated in bold and/or Italics and a value (0.45) was missing at Music care® > NRS pain > p.
Table 2

Symptoms, Analgesia Nociception Index, and physiological variables recorded before and after each of the four relaxation sessions

Type of relaxative techniques
StandardMusic care®VR Deepsen®VR Healthy mind®
Symptoms
NRS overall discomfort
 Before4[2;6]4[2;6]5[2;6]4[2;6]
 After4[2;5]2.5[1;5]4[1,5;5]2[0;5]
 p0.270.060.210.02
NRS pain
 Before2[0;5]2[0;5]3[0;5]2.5[0;5]
 After2[0;5]1[0;5]2[0;4]1[0;4]
 p0.70.450.30.12
NRS anxiety
 Before2,5[0;5]3[0;5]3[0;5]3[0;5]
 After2[0;4]2[0;5]1[0;4]1.7[0;4]
 p0.520.320.030.05
NRS thirst
 Before6[1;9]6[1;8]5[1;8]4[0;7]
 After6[0;8]5[1;8]4[0;8]4[0;6]
 p0.680.530.380.93
NRS Dyspnea
 Before1,5[0;5]2[0;5,5]2[0;5]2[0;4]
 After1[0;4]1[0;4]2[0;5]0,5[0;4]
 p0.890.130.440.5
NRS lack of rest
 Before4[2;6]5[2;7]5[3;8]5[3;8]
 After4[1;6]4[0;5]2[1;5]3.5[2;5]
 p0.490.05 < 0.010.02
ANI and physiological variables
ANI
 Before62[48;85]66[56;82]72[53;80]67[51;80]
 After69[51;82]82[65;93]80[70;98]91[70;98]
 p0.45 < 0.01 < 0.01 < 0.01
Heart rate (/min)
 Before89[81;102]88[80;102]87[78;99]88[77;100]
 After92[79;102]85[81;101]84[74;98]92[80;97]
 p0.880.680.510.69
Respiratory rate (/min)
 Before21[18;24]20[17;26]20[17;25]21[16;27]
 After22[18;27]19[15;24]21[17;26]20[16;24]
 p0.740.340.810.14
Systolic blood pressure (mmHg)
 Before134[120;144]128[117;154]136[121;151]134[118;146]
 After133[119;146]127[113;143]137[120;151]131[115;148]
 p0.990.510.860.82
Diastolic blood pressure (mmHg)
 Before72[65;82]71[62;82]70[62;81]73[65;82]
 After72[64;79]66[61;77]75[61;84]71[62;81]
 p0.520.180.380.65

The data correspond to a rating from 0 to 10 on a numerical rating scale, where 0 is the best and 10 the worst intensity, and are expressed in median [25th–75th percentiles]. The p value was calculated via Mann–Whitney-Wilcoxon test for nonparametric data and via Student’s t test for parametric data

The Italic, bold values are for significant p values

The correct Table 2 is given hereafter. Symptoms, Analgesia Nociception Index, and physiological variables recorded before and after each of the four relaxation sessions The data correspond to a rating from 0 to 10 on a numerical rating scale, where 0 is the best and 10 the worst intensity, and are expressed in median [25th–75th percentiles]. The p value was calculated via Mann–Whitney-Wilcoxon test for nonparametric data and via Student’s t test for parametric data The Italic, bold values are for significant p values Table 2, affiliation 1 and corresponding author e-mail address has been updated in this Publisher Correction article and the original article [1] has been corrected. The publisher apologises to the authors and readers for the inconvenience caused by these mistakes.