Hip aspiration: A comparison of ultrasound and fluoroscopic guidance.

Heather Roesly1, Michael Archibeck2, A Michael Henrie3, Justin Provo3, Justin Foley3, Andrew Boyer4, Masaru Teramoto3, Daniel M Cushman3.   

Abstract

Introduction: Hip aspirations are commonly performed for diagnostic purposes using either fluoroscopic or ultrasound guidance. The superiority of one type of image guidance over another for aspiration of a native or replaced hip remains a matter of debate. The questions to be evaluated in this study include 1) to determine if hip aspiration using fluoroscopy or ultrasound guidance more often obtains fluid from native and post-arthroplasty hip joints, and 2) to identify patient-related factors associated with the ability to obtain fluid. Material and methods: A retrospective analysis of all hip aspirations (433) performed at a single institution was undertaken, with the primary outcome variable being successful attainment of joint fluid. Age, body mass index (BMI), sex, presence of a trainee, presence of an arthroplasty at the time of aspiration on the affected side, amount of fluid collected, and type of image guidance were used as independent variables in regression models.
Results: 1) The likelihood of obtaining fluid was approximately 2.1 times greater with ultrasound guidance than fluoroscopy guidance (95% CI = 1.382, 3.117; p < 0.001). 2) Ultrasound guidance and lower BMI were independently associated with a significantly higher likelihood of obtaining fluid. Additionally, one unit decrease in BMI was associated with about a 3% increase in the odds of obtaining fluid (95% CI = 0.950, 0.998; p = 0.033).
Conclusion: This study demonstrates that the use of ultrasound guidance for hip joint aspiration, when compared to fluoroscopic guidance, is more likely to result in a successful aspiration and the acquisition of a greater volume of fluid. Therefore, ultrasound guidance is the preferred method for hip aspiration in both native and replaced hips.
© 2022 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Fluoroscopy; Hip aspiration; Hip joint; Hip replacement; Ultrasound

Year:  2022        PMID: 36158036      PMCID: PMC9489488          DOI: 10.1016/j.jor.2022.09.010

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  14 in total

1.  Validity of preoperative ultrasound-guided aspiration in the revision of hip prosthesis.

Authors:  Milva Battaglia; Francesca Vannini; Federica Guaraldi; Giuseppe Rossi; Federico Biondi; Alessandra Sudanese
Journal:  Ultrasound Med Biol       Date:  2011-10-27       Impact factor: 2.998

Review 2.  Ultrasound-guided hip joint injections are more accurate than landmark-guided injections: a systematic review and meta-analysis.

Authors:  Shane Hoeber; Abdel-Rahman Aly; Nigel Ashworth; Sathish Rajasekaran
Journal:  Br J Sports Med       Date:  2015-06-10       Impact factor: 13.800

3.  Comparison of ultrasound and fluoroscopic guidance for injection in CT arthrography and MR arthrography of the hip.

Authors:  A Martínez-Martínez; J García-Espinosa; F Ruiz-Santiago; L Guzmán-Álvarez; M M Castellano-García
Journal:  Radiologia       Date:  2016-09-28

4.  Accuracy of CT-guided joint aspiration in patients with suspected infection status post-total hip arthroplasty.

Authors:  Xavier Tomas; Guillem Bori; Sebastián Garcia; Ana Isabel Garcia-Diez; Jaime Pomes; Alex Soriano; Jose Ríos; Manel Almela; Josep Mensa; Xavier Gallart; Juan Carlos Martinez; Josep Riba
Journal:  Skeletal Radiol       Date:  2010-05-08       Impact factor: 2.199

5.  Fluoroscopy- vs ultrasound-guided aspiration techniques in the management of periprosthetic joint infection: which is the best?

Authors:  Filippo Randelli; Marco Brioschi; Pietro Randelli; Federico Ambrogi; Silvana Sdao; Alberto Aliprandi
Journal:  Radiol Med       Date:  2017-09-20       Impact factor: 3.469

6.  Point-of-Care Ultrasound and the Septic Prosthetic Hip Joint.

Authors:  Rachel R Bengtzen; Jesse Lee
Journal:  J Emerg Med       Date:  2019-10-31       Impact factor: 1.484

7.  Image guidance used for large joint and bursa injections; a survey study.

Authors:  Daniel M Cushman; Jacob Christiansen; Melissa Kirk; Nathan D Clements; Shellie Cunningham; Masaru Teramoto; Zachary L McCormick
Journal:  Phys Sportsmed       Date:  2019-10-03       Impact factor: 2.241

8.  Efficacy of preoperative hip aspiration performed in the radiology department.

Authors:  W C Phillips; S V Kattapuram
Journal:  Clin Orthop Relat Res       Date:  1983-10       Impact factor: 4.176

9.  Trends in Utilization of Image Guidance for Hip Joint Injections.

Authors:  Michelle Henne; Alejandro Centurion; Ibrahim Mamdouh Zeini; Donald Harrison Youmans; Daryl Christopher Osbahr
Journal:  Clin J Sport Med       Date:  2021-07-01       Impact factor: 3.638

10.  The Effect of Body Mass Index on Fluoroscopic Time and Radiation Dose During Intra-articular Hip Injections.

Authors:  Daniel M Cushman; Ryan Mattie; Nathan D Clements; Zachary L McCormick
Journal:  PM R       Date:  2016-01-28       Impact factor: 2.298