| Literature DB >> 36141985 |
Robert Alcock1, Magdalena Wajrak2, Jacques Oosthuizen1.
Abstract
Lead levels at a new indoor target shooting range were assessed using both personal and environmental air monitoring methods. Surface swabs were collected from representative locations throughout the range prior to, and at the conclusion of, shooting. Personal samples were compared against the current Australian Workplace Exposure Standards with all results exceeding statutory limits. Static environmental samples exceeded the Air National Environmental Protection Measures (NEPM) air quality standard. Surface swabs showed significant increases from pre- to post-shooting with levels exceeding recommended limits. The performance of the mechanical ventilation system was also assessed and airflow levels were below the required rate at all test locations when compared against the values recommended by the National Institute for Occupational Safety and Health (NIOSH). Users of the indoor shooting range are at risk of potential exposure to hazardous levels of lead. It was recommended the ventilation system be reviewed by a suitably qualified ventilation engineer to ensure it is operating within the required parameters and able to transport generated lead contaminant away from the shooters breathing zone. A thorough cleaning regime should be implemented by the club to minimise surface lead loadings throughout the facility.Entities:
Keywords: indoor; lead; shooting range
Mesh:
Substances:
Year: 2022 PMID: 36141985 PMCID: PMC9517389 DOI: 10.3390/ijerph191811711
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 4.614
Summary of Occupational Exposure Limits and Environmental Guideline Values.
| Source | Description | Standard Name | Type | Value | Unit |
|---|---|---|---|---|---|
| Government of Western Australian | Occupational Exposure Limit | Mines Safety and Inspection Regulations 1995-Inhalable dust | TWA | 10 | mg/m3 |
| Safe Work Australia | Occupational Exposure Limit | Lead, inorganic dusts & fumes (as Pb) | TWA | 0.05 | mg/m3 |
| Air NEPM | National Air Quality Standard | Lead | 1 year average | 0.5 | µg/m3 |
TWA = time weighted average.
Acceptable surface dust lead loadings [18].
| Location | Lead Loading | Unit |
|---|---|---|
| Interior floors | 0.1 | µg/cm2 |
| Interior windowsills | 0.5 | µg/cm2 |
| Exterior Surfaces | 0.8 | µg/cm2 |
Recommended average air velocity [11].
| Location | Airflow | Unit |
|---|---|---|
| Firing line | 0.381 | m/s |
| Minimum—all other locations | 0.254 | m/s |
Summary of personal-exposure monitoring sample results.
| Sample Date | Sample Number | Shooter Number | Description of Shooter Activity | Time On | Time Off | Inhalable Dust (mg/m3) | Inhalable Dust OEL (mg/m3) | Lead (mg/m3) | Lead OEL (mg/m3) |
|---|---|---|---|---|---|---|---|---|---|
| 27/11/2021 | 1 | 1 | Lane 6—Bench | 09:16 | 15:09 | 0.206 | 10 | 0.081 | 0.05 |
| 27/11/2021 | 2 | 2 | Lane 3—Bench | 09:15 | 15:05 | 0.205 | 10 | 0.078 | 0.05 |
| 27/11/2021 | 3 | 3 | Lane 12—Bench | 09:17 | 15:03 | 0.294 | 10 | 0.163 | 0.05 |
| 27/11/2021 | 4 | 4 | Lane 12—Bench | 09:17 | 15:03 | 0.465 | 10 | 0.178 | 0.05 |
| 27/11/2021 | 5 | 5 | Lane 9—Prone | 9:24 | 11:28 | 0.265 | 10 | 0.119 | 0.05 |
| 6 | Lane 7—Bench | 11:29 | 12:02 | ||||||
| 7 | Lane 2—Bench | 13:15 | 14:00 | ||||||
| 8 | Lane 7—Bench | 14:04 | 15:07 | ||||||
| 27/11/2021 | 6 | 9 | Lane 11—Bench | 09:20 | 15:10 | 0.376 | 10 | 0.158 | 0.05 |
| 27/11/2021 | 7 | 10 | Lane 5—Bench | 9:21 | 13:56 | 0.234 | 10 | 0.083 | 0.05 |
| 11 | Lane 8—Bench | 14:03 | 15:14 | ||||||
| 27/11/2021 | 8 | 12 | Lane 2—Bench | 9:23 | 11:26 | 0.153 | 10 | 0.082 | 0.05 |
| 13 | Range Officer | 11:26 | 15:08 |
Summary of Environmental Monitoring Sample Results.
| Sample Date | Sample Number | Location Description | Time On | Time Off | Inhalable Dust (mg/m3) | Inhalable Dust OEL (mg/m3) | Lead (µg /m3) | Air NEPM (µg /m3) |
|---|---|---|---|---|---|---|---|---|
| 27/11/2021 | 9 | South west corner of room adjacent shooting line | 08:05 | 15:18 | 0.017 | 10 | 40 | 0.5 |
| 27/11/2021 | 10 | North west corner of room adjacent shooting line | 08:06 | 15:18 | 0.023 | 10 | 22 | 0.5 |
| 27/11/2021 | 11 | South east corner of room adjacent targets | 08:08 | 15:16 | 0.012 | 10 | 38 | 0.5 |
| 27/11/2021 | 12 | North east corner of room adjacent targets | 08:10 | 15:16 | 0.035 | 10 | 13 | 0.5 |
| 27/11/2021 | 13 | Rear of room behind range officers desk | 08:12 | 15:16 | 0.024 | 10 | 39 | 0.5 |
| 27/11/2021 | 14 | South east corner of room behind target butts | 05:15 | 15:20 | 0.012 | 10 | 58 | 0.5 |
| 27/11/2021 | 15 | North east corner of room behind target butts | 08:16 | 15:21 | 0.035 | 10 | 23 | 0.5 |
Summary of Surface Swab Sample Results.
| Sample Date | Sample Number | Location Description | Sample Area (cm2) | Lead Concentration (µg/cm2) | Acceptable Lead Loading | Comments |
|---|---|---|---|---|---|---|
| 27/11/2021 | SW01 | Range Officers Table—Centre of table | 100 | 0.370 | 0.5 | Pre |
| 27/11/2021 | SW02 | Shooting Bench Lane 2—Centre of bench | 100 | 1.043 | 0.5 | Pre |
| 27/11/2021 | SW03 | Shooting Bench Lane 5—Centre of bench | 100 | 2.110 | 0.5 | Pre |
| 27/11/2021 | SW04 | Shooting Lane 7— | 100 | 0.303 | 0.1 | Pre |
| 27/11/2021 | SW05 | Shooting Lane 9— | 100 | 0.557 | 0.1 | Pre |
| 27/11/2021 | SW06 | Target Face 3—Upper target | 100 | 0.020 | 0.5 | Pre |
| 27/11/2021 | SW07 | Target Face 8—Lower target | 100 | 0.026 | 0.5 | Pre |
| 27/11/2021 | SW08 | Shooting Lane 4— | 100 | 1.019 | 0.5 | Pre |
| 27/11/2021 | SW09 | Shooting Lane 9— | 100 | 0.618 | 0.5 | Pre |
| 27/11/2021 | SW10 | Range Officers Table—Centre of table | 100 | 1.413 | 0.5 | Post |
| 27/11/2021 | SW11 | Shooting Bench Lane 2—Centre of bench | 100 | 8.984 | 0.5 | Post |
| 27/11/2021 | SW12 | Shooting Bench Lane 11— | 100 | 9.444 | 0.5 | Post |
| 27/11/2021 | SW13 | Shooting Lane 7— | 100 | 38.377 | 0.1 | Post |
| 27/11/2021 | SW14 | Shooting Lane 9— | 100 | 19.588 | 0.1 | Post |
| 27/11/2021 | SW15 | Target Face 3—Upper target | 100 | 0.501 | 0.5 | Post |
| 27/11/2021 | SW16 | Target Face 9—Lower target | 100 | 1.320 | 0.5 | Post |
| 27/11/2021 | SW17 | Shooting Lane 4— | 100 | 1.502 | 0.5 | Post |
| 27/11/2021 | SW18 | Shooting Lane 9— | 100 | 2.408 | 0.5 | Post |
Summary of airflow measurements.
| Sample Date | Measurement Number | Location Description | Airflow Range Live (m/s) | Airflow Range Closed (m/s) | Required Airflow (m/s) |
|---|---|---|---|---|---|
| 27/11/2021 | 1 | Shooting line, northern side of room | 0.00 | 0.00 | 0.381 |
| 27/11/2021 | 2 | Shooting line, center of range | 0.01 | 0.00 | 0.381 |
| 27/11/2021 | 3 | Shooting line, Southern side of room | 0.12 | 0.01 | 0.381 |
| 27/11/2021 | 4 | Centre of range, northern side of room | 0.01 | 0.00 | 0.254 |
| 27/11/2021 | 5 | Centre of range, center of room | 0.01 | 0.01 | 0.254 |
| 27/11/2021 | 6 | Centre of range, southern side of room | 0.06 | 0.00 | 0.254 |
| 27/11/2021 | 7 | Adjacent targets, northern side of room | 0.01 | 0.00 | 0.254 |
| 27/11/2021 | 8 | Adjacent targets, center of range | 0.01 | 0.00 | 0.254 |
| 27/11/2021 | 9 | Adjacent targets, Southern side of room | 0.04 | 0.00 | 0.254 |
| 27/11/2021 | 10 | Behind target butts, | 0.02 | 0.00 | 0.254 |
| 27/11/2021 | 11 | Behind target butts, center of range | 0.02 | 0.00 | 0.254 |
| 27/11/2021 | 12 | Behind target butts, | 0.06 | 0.00 | 0.254 |
Figure 1Supply air ducting and outlets.
Figure 2Mechanical extraction fans.