Daniel G Beach1, Meghann Bruce2, Janice Lawrence3, Pearse McCarron1. 1. Biotoxin Metrology, National Research Council Canada, 1411 Oxford Street, Halifax, Nova Scotia B3H 3Z1, Canada. 2. Canadian Rivers Institute, University of New Brunswick, P.O. Box 4400, Fredericton, New Brunswick E3B 5A3, Canada. 3. Department of Biology, University of New Brunswick, 10 Bailey Drive, Fredericton, New Brunswick E3B 5A3, Canada.
Abstract
Toxic benthic cyanobacterial mats are increasingly reported worldwide as being responsible for animal mortalities due to their production of the potent neurotoxin anatoxin-a (ATX) and its analogues. Improved analytical methods for anatoxins are needed to address public health and watershed management challenges arising from extremely high spatial and temporal variability within impacted systems. We present the development, validation, and application of a direct analysis in real-time-high-resolution tandem mass spectrometry (DART-HRMS/MS) method for analysis of anatoxins in cyanobacterial field samples, including a simplified sample preparation approach. The method showed excellent sensitivity and selectivity for ATX, homoanatoxin-a, and dihydroanatoxin-a. Isotopically labeled ATX was used as an internal standard for all three analogues and successfully corrected for the matrix effects observed (86 ± 16% suppression). The limit of detection and recovery for ATX was estimated as 5 ng/g and 88%, respectively, using spiked samples. The total analysis time was ∼2 min, and excellent agreement was observed with results from a liquid chromatography-HRMS reference method. Finally, the DART-HRMS/MS method was applied to a set of 45 Microcoleus-dominated benthic cyanobacterial mat samples from the Wolastoq near Fredericton, Canada, demonstrating its power and applicability in enabling broad-scale field studies of ATX distribution.
Toxic benthic cyanobacterial mats are increasingly reported worldwide as being responsible for animal mortalities due to their production of the potent neurotoxin anatoxin-a (ATX) and its analogues. Improved analytical methods for anatoxins are needed to address public health and watershed management challenges arising from extremely high spatial and temporal variability within impacted systems. We present the development, validation, and application of a direct analysis in real-time-high-resolution tandem mass spectrometry (DART-HRMS/MS) method for analysis of anatoxins in cyanobacterial field samples, including a simplified sample preparation approach. The method showed excellent sensitivity and selectivity for ATX, homoanatoxin-a, and dihydroanatoxin-a. Isotopically labeled ATX was used as an internal standard for all three analogues and successfully corrected for the matrix effects observed (86 ± 16% suppression). The limit of detection and recovery for ATX was estimated as 5 ng/g and 88%, respectively, using spiked samples. The total analysis time was ∼2 min, and excellent agreement was observed with results from a liquid chromatography-HRMS reference method. Finally, the DART-HRMS/MS method was applied to a set of 45 Microcoleus-dominated benthic cyanobacterial mat samples from the Wolastoq near Fredericton, Canada, demonstrating its power and applicability in enabling broad-scale field studies of ATX distribution.
Cyanobacteria
are globally ubiquitous but can cause environmental
and human health problems when they multiply to high cell concentrations
in the aquatic environment. This can include either dense surface
blooms or the proliferation of benthic cyanobacterial mats, which
grow on rocks, sediment, or macrophytes on the bottoms of lakes or
rivers. There are increasing reports of toxic benthic cyanobacterial
proliferations worldwide, which are often associated with animal deaths
caused by the potent neurotoxin anatoxin-a (ATX).[1−5] In many cases, toxicity can be attributed to cyanobacteria
of the genera Microcoleus, Phormidium, or Oscillatoria, which are morphologically similar and poorly resolved by genetics
and taxonomy.[1,6]There are several challenges
associated with studying, monitoring,
and assessing risks associated with benthic ATX-producing cyanobacteria.
These include analytical challenges such as the low molecular weight,
high polarity, and poor stability of ATX, the complex assemblages
of cyanobacteria and other microorganisms found in benthic microbial
mats, as well as the overall high spatial and temporal variability
in mat occurrence and ATX concentration.[1,7−9]ATX typically exists in the environment as a mixture with
other
structural analogues, usually homoanatoxin-a (hATX) and dihydroanatoxin-a
(H2-ATX), collectively referred to as anatoxins (ATXs, Figure ). ATXs can be analyzed
using a variety of chemical and biochemical techniques, with liquid
chromatography–mass spectrometry (LC–MS)[10−16] being the most common for quantitative analysis. Immunochemical
and receptor binding assays are also commercially available.[17,18] High-resolution mass spectrometry (HRMS) is particularly effective
at resolving ATX from its common isobaric interference phenylalanine,
which can cause interference and ionization suppression in some MS-based
methods.[16,19−21] The improved selectivity
of HRMS over low-resolution MS instruments has also enabled the use
of direct ionization techniques for ATX analysis including direct
analysis in real time (DART),[22] matrix-assisted
laser desorption ionization,[20] and laser-induced
thermal desorption ionization.[21,23] These techniques offer
the potential for higher throughput than LC–MS because of their
lack of chromatographic separation and reduced requirement for sample
preparation but also pose challenges in selectivity and matrix effects.
Recently, excellent selectivity and sensitivity were demonstrated
for analysis of ATX and hATX by full-scan DART–HRMS in cultured
cyanobacteria with a limit of detection (LOD) of 1 ng/mL and excellent
quantitative agreement with LC–HRMS.[22] However, the significant impact of matrix effects on accuracy (50%
suppression) and high sample-to-sample variability (30% RSD) of the
method, which used single-point matrix-matched calibration, were highlighted
as limitations in need of further study.
Figure 1
Structures and formulae
of anatoxins and internal standards analyzed
in this study. Asterisks indicate sites of 13C labeling
on 13C4-ATX.
Structures and formulae
of anatoxins and internal standards analyzed
in this study. Asterisks indicate sites of 13C labeling
on 13C4-ATX.In the summers of 2018 and 2019, dogs died of acute neurological
symptoms after spending time on the shore of the Wolastoq (Saint John
River) near Fredericton, New Brunswick, Canada.[24] Despite the fact that this area had not previously been
associated with significant cyanobacterial blooms, ATXs were identified
in samples associated with the poisonings, and a widespread proliferation
of benthic cyanobacterial mats was discovered in the area. This has
led to increased study of the drivers of mat occurrence and toxicity,
as well as highlighting the challenges of monitoring and managing
this emerging problem in the region, all of which have emphasized
the need for rapid and reliable analytical methods for ATXs.Here, we describe the development and validation of a DART–HRMS/MS
method for the analysis of ATXs in complex cyanobacterial mat field
samples. This includes refinement of our earlier full-scan method[22] to gain the selectivity needed for analysis
in a complex cyanobacterial mat field sample matrix using HRMS/MS,
the quantitation of another common ATX analogue, H2-ATX,
and mitigation of matrix effects using an isotopically labeled ATX
standard. We also present the development of a simple sample preparation
method for cyanobacteria that is amenable to higher throughput analysis.
Throughout method development and validation, we relied on a highly
sensitive LC–HRMS reference method for ATXs to gain confidence
in the performance of the DART–HRMS/MS method. Finally, we
applied the developed method to a set of cyanobacterial mat samples
from the Wolastoq in order to investigate spatial and temporal trends
and intermat variability of ATXs in a real system.
Experimental Section
Chemicals and Reagents
A certified
reference material calibration solution for ATX (NRC CRM-ATX-a) and
an in-house calibration solution for hATX[25] were obtained from the National Research Council Canada (Halifax,
Nova Scotia). Standards of 13C4-(+)-anatoxin-a
(13C4-ATX) and H2-ATX were purchased
from Eurofins Abraxis (Warminster, PA, USA).Methanol and acetonitrile
(Optima LC–MS grade) were from Fisher (Ottawa, ON, Canada).
Formic acid (LC–MS grade) and L-phenyl(2H5)alanine were from Sigma-Aldrich (Oakville, ON, Canada).
Deionized water was produced by passing distilled water through a
Milli Q Reference A+ System (Millipore, Bedford, MA, USA).
Cyanobacterial Mat Sample Collection and Preparation
Initial method development was carried out on a set of 10 cyanobacterial
samples that included benthic mats collected in Nova Scotia in 2019[26] and samples of Microcoleus-dominated mats collected in the summers of 2019
and 2020 from the Wolastoq (Saint John River) near Fredericton, New
Brunswick (coordinates in Table S1). For
validation using LC–HRMS, the sample set was expanded with
35 additional samples of the cyanobacterial mat and their associated
sediment collected along the Wolastoq during the summers of 2018,
2019, and 2020.Samples were collected in 15 mL sterile centrifuge
tubes, maintained at ambient temperatures, and homogenized within
24 h of collection using 15 mL disposable tissue grinders (VWR International,
Radnor, PA, USA). Once ground, homogenized samples were stored at
−20 °C prior to further processing.Prior to analysis,
subsamples of thawed homogenate (∼1 mL)
were centrifuged at 21 000 g at 4 °C
for 20 min. A subsample of the supernatant (100 μL) was then
transferred to a 0.22 μm Innosep PVDF spin filter (Canadian
Life Sciences, Peterborough, ON, Canada), immediately mixed with 100
μL of 120 ng/mL 13C4-ATX in methanol and
centrifuged at 6720 g for 5 min at room temperature,
and analyzed by DART–HRMS/MS and LC–HRMS. This filtration
step was only required in cases where samples were also to be run
by LC–HRMS as DART–HRMS/MS did not require samples to
be filtered.
DART–HRMS
All experiments
were carried out on a Q Exactive HF Orbitrap mass spectrometer (Thermo,
Waltham, MA, USA). A DART-SVP source was coupled to the mass spectrometer
using a Vapur interface (Ionsense, Saugus, MA). Optimized DART–HRMS
parameters included the use of He as the DART gas, a DART temperature
of 350 °C, a capillary temperature of 200 °C, a max IT fill
time of 300 msec, and an S-Lens RF level of 50 (arbitrary units).
MS data were collected simultaneously in full-scan (FS) mode with
a m/z 150 to 250 mass range, as
well as tandem mass spectrometry (MS/MS) for precursor ions of m/z 166.1 (ATX), 168.1 (H2-ATX),
180.1 (hATX), and 170.1 (13C4-ATX), using the
parallel reaction monitoring scan mode with a collision energy (CE)
of 15 V, a 0.4 m/z isolation window,
and the 30 000 resolution setting. Product ions used for quantitation
were the [M + H − NH3]+ ions for ATX,
hATX, and 13C4-ATX at m/z 149.0961, 163.1117, and 153.1095, respectively, as well
as the [M + H – C2H3N]+ ion
at m/z 125.0961 for H2-ATX.Samples were introduced by pipetting 5 μL of the
extract onto the tip of a Dip-it sampling rod (Ionsense) held manually,
approximately midway between the DART source and the ceramic interface
tube for 10 s. All samples were analyzed in triplicate and a mixed
standard (43 ng/mL ATX, 46 ng/mL hATX, 37 ng/mL H2-ATX,
and 60 ng/mL 13C4-ATX) was run approximately
every 10 samples.Peak areas for quantitation were integrated
manually in Xcalibur
4.0 software from chronograms of product ion m/z extracted with ± 5 ppm mass windows. Calibration
of ATX was carried out by single-point double-isotope dilution using
the ratio of 13C4-ATX:ATX in the spiked sample
and standard, as followswhere [ATX]sample is the concentration
of ATX in the field sample and [ATX]standard is the ATX
concentration in the neat ATX standard.The concentrations of
hATX and H2-ATX were determined
by single-point external calibration corrected with the suppression
factor for 13C4-ATX in each sample as in the
following example for hATXwhere is the suppression factor for a particular
field sample.
LC–HRMS Analysis
LC–HRMS
analyses were performed using an Agilent 1200 LC system (Agilent,
Santa Clara, CA, USA) coupled to the mass spectrometer described above
with a HESI-II heated ESI interface (ThermoFisher Scientific, Waltham,
MA, USA). All LC separations were performed with an injection volume
of 1 μL using an HSS T3 1.8 μm C18 column (100
× 2.1 mm; Waters, Milford, MA, USA) held at 40 °C with mobile
phases A and B of H2O and acetonitrile, respectively, both
containing 0.1% v/v formic acid. The elution gradient (0.2 mL/min)
included a linear increase from 2 to 11% B over 25 min and then to
95% B over 0.1 min, followed by a 4.9 min hold at 95% B, with re-equilibration
at 2% B for 5 min. HRMS data was acquired in positive ion mode using
a combined FS and targeted MS/MS method. FS data were collected from m/z 100 to 500 using the 30 000
resolution setting, an AGC target of 1 × 106, and
a max IT of 100 ms. MS/MS spectra were acquired as for DART–HRMS/MS
described above.Calibration for ATX in LC–HRMS analysis
was carried out by single-point double-isotope dilution, as described
above for DART–HRMS. Homoanatoxin-a and H2-ATX were
measured by external calibration. When signal intensity allowed, a
100-fold dilution with 1:1 MeOH/H2O was carried out to
minimize matrix effects in LC–HRMS. Two H2-ATX diastereomer
peaks at different retention times with MS/MS spectra matching that
of H2-ATX were observed in LC–HRMS, as reported
previously,[15,27] and were summed in both standards
and samples.
Results and Discussion
DART–HRMS/MS Method Development
The original
goal of this work was to apply a recently reported DART–HRMS
method, which was developed for screening ATXs in laboratory cultures
of cyanobacteria,[22] to benthic cyanobacterial
mat samples from the Wolastoq in New Brunswick, Canada. However, benthic
cyanobacterial mats are highly complex, both in terms of the biological
community and the chemical matrix present in sample extracts, which
has previously led to problems in analytical selectivity in some methods.[5] Throughout the study, results from DART analysis
of field samples were compared to those obtained using an LC–HRMS reference method in order to assess selectivity
and accuracy. The LC–HRMS method has a LOD
of 0.1 ng/mL in culture extracts and excellent resolution of the ATXs
from each other (Figure S1) and potential
matrix interferences such as phenylalanine (Phe).[22] In order to evaluate the suitability of the FS DART method
for analysis of ATXs in a more complex matrix, a preliminary set of
10 cyanobacterial field samples was analyzed by both DART–HRMS and LC–HRMS. This analysis showed that in several cases,
high concentrations of ATXs were determined by DART–HRMS in the absence of detection of ATXs by LC–HRMS (Figure S2). This was particularly
true for hATX but also for ATX and H2-ATX in some samples,
even when using the maximum FS resolution setting of 240 000.
The differences observed were attributed to poor selectivity, making
the previous DART–HRMS method unsuitable for
the analysis of ATXs in field samples.The additional selectivity
of MS/MS was therefore investigated as a way of improving method performance.
Product ions and CE used for quantitation were chosen experimentally
based on selectivity and sensitivity. While low-mass product ions
(e.g., C3H6N+ ions at m/z 56.0495 for ATX and H2-ATX) showed
the highest overall signal intensity at moderate CE (Figure S3), these showed relatively poor selectivity compared
with higher mass product ions at lower CE. A CE of 15 V was therefore
chosen for all further experiments, with product ion spectra for ATX,
hATX, H2-ATX, and 13C4-ATX in standards
and samples shown in Figure S4. No significant
advantage in selectivity was observed by increasing the resolution
setting in MS/MS beyond the minimum setting of 15 000 in test
samples, but since a setting of 30 000 did not show any disadvantage
in MS cycle time, it was used going forward. Excellent selectivity
between ATX and its common interference Phe was also observed in HRMS/MS
(Figure S5), where no significant signal
was observed from Phe for the m/z 149.0959 product ion used for quantitative analysis of ATX by DART–HRMS/MS. Using this DART–HRMS/MS method, excellent agreement was observed with LC–HRMS in all cases for the preliminary sample set (Figure S2).As found previously for culture extracts,[22] sample introduction by pipetting 5 μL
of liquid sample onto
a Dip-it sampling rod and manually introducing it into the space between
the DART source and the MS inlet for 10 s was found to be simple and
effective. No impact on the DART peak area was observed with small
deviations of positioning between the DART source and the MS inlet,
although holding the sampling rod steady was important for achieving
a good DART peak shape. While potentially improving method automation,
spotting of samples and standards onto steel mesh sampling cards (Open-Spot)
consistently showed reduced ATX sensitivity when a new card was used
compared to cards that had been used previously, even though sample
carryover was ruled out as a possible cause.In order to facilitate
method throughput, a simple extraction procedure
was developed that required only sample homogenization, cell lysis,
and centrifugation. This was possible due to the high moisture content
in the majority of mat samples. After sample homogenization, cell
lysis by freeze/thaw and centrifugation, the resulting supernatant,
consisting primarily of interstitial liquid from the mats and cell
contents, could be analyzed directly by DART without filtration. No
significant difference in sensitivity or precision was observed between
aqueous cyanobacterial mat extracts and those containing 50 or 75%
methanol; however, samples that contained methanol evaporated slightly
more rapidly, resulting in sharper DART peaks. Samples of the supernatant
were therefore diluted 1:1 with MeOH prior to analysis.The
use of an isotopically labeled internal standard was investigated
in order to improve method precision and accuracy. Deuterated phenylalanine
(2H5-Phe), an internal standard previously reported
for the analysis of ATX using laser diode thermal desorption,[21] was first investigated for use with DART. However,
when spiked into a series of field sample extracts at 100 ng/mL, the 2H5-Phe signal was almost completely suppressed,
and therefore, it was not useful as an internal standard with DART
(Figure S6).An isotopically labeled
ATX standard (13C4-ATX) was therefore used to
develop a double-isotope dilution calibration
approach for quantitation of ATX in both LC–HRMS and DART–HRMS/MS
(eq ). Unlike in LC–HRMS,
where ATXs are separated chromatographically and detected at different
retention times with different mobile-phase compositions and coeluting
matrix compounds, both of which affect ionization efficiency, all
analytes in DART–HRMS are ionized simultaneously. This meant
that 13C4-ATX could also confidently be used
to effectively correct for the suppression observed for hATX and H2-ATX by applying a suppression factor determined from the
ratio of ATX response between standard and each sample to the results
of external calibration (eq ). For quantitative screening of field samples, a spike concentration
of 60 ng/mL was chosen to match WHO guidelines for short-term exposure
to ATX in recreational waters.[28] To further
simplify the sample preparation method, sample spiking was done by
making a 120 ng/mL stock solution of 13C4-ATX
in MeOH, which was used to carry out the 1:1 dilution of mat lysate
samples.Using this approach, results were obtained in units
of μg/mL
of mat lysate, but for many applications, it may be more desirable
to obtain a mass fraction value for ATXs in benthic cyanobacterial
mats. Given their high moisture content, it was reasoned that μg/mL
concentrations in mat lysates were similar to mg/kg wet weight mass
fractions in the mats themselves. In order to establish the equivalence
of these units, 15 mat samples were homogenized and split into two
subsamples, with one-half being weighed and extracted with 50% MeOH
and the other half being centrifuged and analyzed directly after spiking,
as described above. An excellent correlation with a slope of 1.0 was
observed between the two sample preparation approaches (Figure S7), with a 16 ± 12% absolute difference
in ATX measured in ng/mL and ng/g (average ± standard deviation, N = 15). This was considered acceptable for the intended
application of rapid quantitative screening, and concentrations are
therefore reported as mg/kg wet weight going forward based on the
described lysate procedure.Chronograms showing triplicate analysis
of a mixed ATX standard
and a selection of 13C4-ATX spiked mat samples
from site 3 on the Wolastoq (Table S1)
are shown in Figure . The variability in the sensitivity of 13C4-ATX between samples, which was spiked at 60 ng/mL in all samples
and standards, demonstrated the wide range in signal suppression observed
between samples in DART–HRMS, which was however effectively
corrected using the internal standard.
Figure 2
Extracted ion chronograms
from DART–HRMS/MS showing triplicate
analysis of a mixed anatoxin standard and six benthic cyanobacterial
mat samples collected from site 3 on the Wolastoq in 2019 spiked with
60 ng/mL 13C4-ATX. Traces show extracted product
ion m/z of 149.0961, 163.1117, 125.0961,
and 153.1095 ± 5 ppm for ATX, hATX, H2-ATX, and 13C4-ATX, respectively.
Extracted ion chronograms
from DART–HRMS/MS showing triplicate
analysis of a mixed anatoxin standard and six benthic cyanobacterial
mat samples collected from site 3 on the Wolastoq in 2019 spiked with
60 ng/mL 13C4-ATX. Traces show extracted product
ion m/z of 149.0961, 163.1117, 125.0961,
and 153.1095 ± 5 ppm for ATX, hATX, H2-ATX, and 13C4-ATX, respectively.
Quantitative Capabilities of DART–HRMS/MS
The primary benefit of DART is the rapid analysis time, but it
was also evident that the DART–HRMS/MS method also possesses
quantitative capabilities beyond those of a qualitative screening
method. The typical quantitative figures of merit were thus investigated
and are compared to those of the LC–HRMS reference method (Table ). Matrix-matched
and neat ATX, hATX, and H2-ATX calibration curves were
analyzed by both methods. Estimated LODs for LC–HRMS were based
on the signal-to-noise ratio (S/N) of low-level standards spiked into
a pooled sample of cyanobacterial mat sample extracts that were negative
for ATXs by LC–HRMS, with the LOD, defined as S/N = 3. These
same samples were also analyzed by DART–HRMS/MS, but the LOD
was defined as the concentration at which a signal of 3× the
background detected in the pooled control extract would be measured.
This approach was chosen because of the variable signal background
in DART–HRMS, hindering reliable calculations of S/N values.
The LOD reported for H2-ATX (24 μg/kg) was significantly
higher than that for ATX (4.8 μg/kg) and hATX (2.4 μg/kg),
which can be attributed to lower sensitivity and higher chemical background
observed in DART for the precursor–product ion combination
used in H2-ATX quantitation. The LODs estimated from the
spiked pooled control sample are directly related to the level of
ionization suppression in that particular sample, which was relatively
high at 96 ± 1% suppression (SD, N = 18). Because 13C4-ATX was spiked at 60 ng/mL into all of the
real samples and standards in the study, it was also possible to assess
the suppression observed in each individual sample, which was usually
somewhat lower than the pooled control sample at 86 ± 16% RSD
(N = 34) but significantly higher than in LC–HRMS
at 19 ± 24% RSD (N = 33). The sample-specific
suppression factors could further be used to estimate individual LODs
for each sample, which varied significantly between 0.3 and 23 μg/kg
with an average of 4.7 μg/kg for ATX. This approach could be
useful in the future in establishing expected levels of detection
in negative samples.
Table 1
Figures of Merit
of the DART–HRMS/MS
Method Compared to Those of the LC–HRMS Reference Method
figure of
merit
toxin
LC–HRMS
DART–HRMS/MS
estimated LOD (μg/kg)
ATX
0.13
4.8
hATX
0.11
2.4
H2-ATX
0.15
24
precision
(% relative standard
deviation, N = 3)
ATX
4a
23 ± 11b
% suppression (N = 34)
ATX
19 ± 24
86 ± 16
linearity (R2)
ATX (0.14–86 ng/mL)
>0.9999
0.9999
hATX (0.15–91 ng/mL)
>0.9999
0.9994
H2-ATX (0.12–74 ng/mL)
>0.9999
0.9998
15 μg/kg spike
recovery (N = 5)
ATX
83 ± 5
82 ± 11
hATX
66 ± 4
102 ± 19
H2-ATX
58 ± 1
83 ± 14
150 μg/kg spike
recovery (N = 5)
ATX
83 ± 3
84 ± 15
hATX
82 ± 6
101 ± 12
H2-ATX
75 ± 3
76 ± 13
run time (min)
30 (single injection)
2 (triplicate analysis)
Percent relative
standard deviation
of triplicate analysis of ATX in a cyanobacterial reference material.[25]
Average
% relative standard deviation
of triplicate analysis of ATX in 23 field samples.
Percent relative
standard deviation
of triplicate analysis of ATX in a cyanobacterial reference material.[25]Average
% relative standard deviation
of triplicate analysis of ATX in 23 field samples.Method accuracy was assessed by
spike recovery experiments (Table ) and by comparing
the results of real sample analysis by DART–HRMS/MS to those
from LC–HRMS (Figure ). Recovery was determined by spiking 0.4 g subsamples of
five different negative field samples with 25 μL of a mixed
standard of ATX, hATX, and H2-ATX to give concentrations
of either 15 ng/g or 150 ng/g each and then extracting following the
developed procedure. Overall method performance was assessed by comparing
DART–HRMS/MS results from all 45 benthic cyanobacterial mat
samples to those from LC–HRMS. For ATX, where double-isotope
dilution was used for both methods, excellent recoveries of 82–84%
were observed along with an excellent correlation between the two
methods (slope = 0.99, R2 = 0.98). Good
general agreement was also observed for hATX and H2-ATX,
where a combination of external calibration and sample dilution was
used in LC–HRMS calibration, but results from DART–HRMS/MS
were consistently slightly higher than those from LC–HRMS for
these analogues.
Figure 3
Quantitative analysis of anatoxin-a(A), homoanatoxin-a
(B), and
dihydroanatoxin-a (C) in 45 cyanobacterial mat samples by DART–HRMS/MS
compared to those from LC–HRMS. Dashed lines show linear regression
of each plot with the equations and coefficient of determination (R2) given. Low-level results (<0.1 mg/kg)
are shown in the insets.
Quantitative analysis of anatoxin-a(A), homoanatoxin-a
(B), and
dihydroanatoxin-a (C) in 45 cyanobacterial mat samples by DART–HRMS/MS
compared to those from LC–HRMS. Dashed lines show linear regression
of each plot with the equations and coefficient of determination (R2) given. Low-level results (<0.1 mg/kg)
are shown in the insets.Only one false positive
was observed by DART–HRMS, with
0.005 mg/kg ATX being detected in a sample showing no ATXs by LC–HRMS.
In all cases, samples showing ATXs by LC–HRMS above the estimated
DART LODs were found to contain ATXs by DART–HRMS, although
some differences in detection were observed for individual analogues
in very low-level samples. In the future, appropriate thresholds in
precursor and product ion mass accuracy and product ion ratio could
be assigned to ensure that results are appropriate for the quantitative
requirements of a given study.
Applications
of DART–HRMS/MS to Benthic
Cyanobacterial Mat Field Samples
The main motivation for
this work was to develop an analytical method to enable a large-scale
study of toxin distribution in benthic cyanobacterial mats. To demonstrate
this application, DART–HRMS/MS results from 21 benthic cyanobacterial
mats from the Wolastoq collected during a survey in the summer of
2019 were analyzed to study temporal and spatial trends as well as
intermat variability (Figure ). This included samples collected over a 2 day period in
July 2019 (Figure A) at eight sites along the impacted section of the river between
the Mactaquac Dam and the city of Fredericton, NB, Canada (Figure B), as well as samples
collected from a single site over the course of the summer (Figure C). These results
show high environmental variability, even between mat samples taken
from the same site at the same time. This is consistent with observations
from similarly impacted sites elsewhere[8] and has been attributed to variability in the relative abundance
of toxic genotypes.[29] Despite this high
within-site variability, a clear trend of increasing ATX concentrations
peaking in mid-August followed by a drop to trace levels in September
was observed at sample site 3 over the course of the summer. The results
from DART–HRMS/MS and LC–HRMS analysis of the samples
from Figure are provided
in Table S1 and show excellent agreement,
further highlighting the suitability of DART for this type of environmental
analysis.
Figure 4
Spatial and temporal variability of total anatoxins in benthic
cyanobacterial mat samples from the Wolastoq as measured by DART–HRMS/MS.
Spatial variability (A) in samples collected on July 30th and 31st,
2019, where separate bars indicate individual samples taken from each
site (B) and temporal variability (C) in samples collected from site
3 throughout the summer of 2019. Error bars show the standard deviation
of triplicate analysis of a single sample.
Spatial and temporal variability of total anatoxins in benthic
cyanobacterial mat samples from the Wolastoq as measured by DART–HRMS/MS.
Spatial variability (A) in samples collected on July 30th and 31st,
2019, where separate bars indicate individual samples taken from each
site (B) and temporal variability (C) in samples collected from site
3 throughout the summer of 2019. Error bars show the standard deviation
of triplicate analysis of a single sample.The main advantages of DART–HRMS/MS were the rapid analysis
(2 min/triplicate analysis) and simplified sample preparation. Limitations
of the DART–HRMS/MS method included higher RSDs (on the order
of 30% between replicate analyses) as well as higher and variable
LOD when compared with LC–HRMS. However, considering the very
high environmental variability and often high concentrations of ATXs
observed in samples collected from the Wolastoq, these limitations
are not viewed as significant for the current application.The
2019 samples from the Wolastoq analyzed in this study were
collected as part of an ongoing survey of benthic cyanobacterial mat
distribution and population genetics. Since genetic analysis already
requires cell lysis and sample homogenization, the addition of DART–HRMS/MS
analysis was procedurally extremely simple, requiring only centrifugation
and dilution of a subsample of supernatant with an internal standard.
Future work will include the application of the DART–HRMS/MS
method developed here to a broader study of the cyanobacterial mat
and ATX occurrence in the Wolastoq. In the future, automation of sample
introduction to DART would offer even greater improvements in sample
throughput, further enabling large-scale studies of ATXs in large
proliferations of benthic cyanobacterial mats.
Authors: Andrew I Selwood; Patrick T Holland; Susanna A Wood; Kirsty F Smith; Paul S McNabb Journal: Environ Sci Technol Date: 2007-01-15 Impact factor: 9.028
Authors: Nijoy John; Louise Baker; Brendan R E Ansell; Steven Newham; Nicholas D Crosbie; Aaron R Jex Journal: Sci Rep Date: 2019-07-26 Impact factor: 4.379