Literature DB >> 3611177

Endoprosthetic replacement of the proximal humerus.

A C Ross, J N Wilson, J T Scales.   

Abstract

Endoprosthetic replacement of the proximal humerus has been performed in our unit on 25 occasions between 1950 and 1982. The indication for surgery was destruction of the proximal half of the humerus so extensive that the only alternatives were reconstruction or amputation. Of the patients with tumours two died from metastases, and three from unrelated causes; local recurrence necessitated amputation in two patients. Minor complications were frequent, but there were no deep infections and, after 1964, no prosthesis became loose. Active shoulder movement after operation was considerably limited, but passive movement was good and function of the elbow and hand were preserved.

Entities:  

Mesh:

Year:  1987        PMID: 3611177

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  16 in total

1.  Refixation of muscular insertions after endoprosthetic replacement of the proximal humerus.

Authors:  P Ritschl; H Piza-Katzer; U Pechmann; R Kotz
Journal:  Arch Orthop Trauma Surg       Date:  1989       Impact factor: 3.067

2.  Proximal and total humerus reconstruction with the use of an aortograft mesh.

Authors:  German A Marulanda; Eric Henderson; David Cheong; G Douglas Letson
Journal:  Clin Orthop Relat Res       Date:  2010-11       Impact factor: 4.176

3.  Custom-made endoprosthetic total humerus reconstruction for musculoskeletal tumours.

Authors:  Mayil Natarajan; Mohamed Sameer; Dheep Kunal; Navin Balasubramanian
Journal:  Int Orthop       Date:  2011-07-28       Impact factor: 3.075

4.  Silver-coated endoprosthetic replacement of the proximal humerus in case of tumour-is there an increased risk of periprosthetic infection by using a trevira tube?

Authors:  Jan Schmolders; Sebastian Koob; Paul Schepers; Michael Kehrer; Sönke Percy Frey; Dieter Christian Wirtz; Peter Heinrich Pennekamp; Andreas Christian Strauss
Journal:  Int Orthop       Date:  2016-11-09       Impact factor: 3.075

5.  Endoprosthetic reconstruction of the proximal humerus after tumour resection with polypropylene mesh.

Authors:  Baichuan Wang; Qiang Wu; Jianxiang Liu; Shuhua Yang; Zengwu Shao
Journal:  Int Orthop       Date:  2014-11-23       Impact factor: 3.075

6.  Synthetic mesh improves shoulder function after intraarticular resection and prosthetic replacement of proximal humerus.

Authors:  Xiaodong Tang; Wei Guo; Rongli Yang; Shun Tang; Tao Ji
Journal:  Clin Orthop Relat Res       Date:  2015-01-21       Impact factor: 4.176

7.  Outcomes of major musculoskeletal oncological reconstructions using prolene mesh-a retrospective analysis from a tertiary referral centre.

Authors:  Love Kapoor; Roshan Banjara; Ashish Ragase; Abdul Majeed; Venkatesan Sampath Kumar; Shah Alam Khan
Journal:  J Clin Orthop Trauma       Date:  2021-01-04

8.  An Initial Experience of Shoulder Resections and Reconstruction for Bone Tumours from a Cancer Centre in North-East India.

Authors:  Gaurav Das; Srinivas Bannoth; Bibhuti Bhusan Borthakur; Sumanjit Boro; Revanth Kumar; Pritesh Singh; Jitin Yadav
Journal:  Indian J Surg Oncol       Date:  2021-03-08

9.  Chondrosarcoma of the proximal humerus secondary to ollier disease: an 8-year follow-up of successful resection of the tumor with endoprosthetic replacement of the proximal humerus.

Authors:  Kang Zheng; Zhao Xiang Peng; Ping Pin Zheng
Journal:  J Clin Med Res       Date:  2014-03-31

10.  Partial humeral replacement for peri-prosthetic fractures of the humerus.

Authors:  Ruben Manohara; Colin R Howie
Journal:  J Clin Orthop Trauma       Date:  2017-05-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.