Literature DB >> 3611176

Endoprosthetic replacement of the humerus and elbow joint.

A C Ross, R S Sneath, J T Scales.   

Abstract

Between 1969 and 1985 26 patients with destructive lesions of the distal humerus were treated by endoprosthetic replacement; each implant was custom-made and incorporated part of the distal humerus or the entire bone as well as a hinged total elbow replacement. Recurrence occurred in three of the patients with tumours, and three prostheses were removed because of deep infection in patients with previously compound injuries of the elbow. Another three loosened without infection, but none needed revision or removal and no amputations resulted. Other complications included nerve palsies, but the only deaths were from metastases. A useful range of elbow movement, with a stable arm and good hand function, was achieved in every patient.

Entities:  

Mesh:

Year:  1987        PMID: 3611176

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  13 in total

Review 1.  [Allograft reconstruction in revision elbow arthroplasty].

Authors:  F Moro
Journal:  Orthopade       Date:  2017-12       Impact factor: 1.087

2.  [Modular tumor prostheses of the humerus].

Authors:  P T Funovics; M Dominkus
Journal:  Orthopade       Date:  2010-10       Impact factor: 1.087

3.  Silver-coated endoprosthetic replacement of the proximal humerus in case of tumour-is there an increased risk of periprosthetic infection by using a trevira tube?

Authors:  Jan Schmolders; Sebastian Koob; Paul Schepers; Michael Kehrer; Sönke Percy Frey; Dieter Christian Wirtz; Peter Heinrich Pennekamp; Andreas Christian Strauss
Journal:  Int Orthop       Date:  2016-11-09       Impact factor: 3.075

4.  Total humerus replacement for osteosarcoma with proximal part of humerus: a case report.

Authors:  Yukihiro Yoshida; Yasuaki Tokuhashi
Journal:  World J Surg Oncol       Date:  2012-02-14       Impact factor: 2.754

Review 5.  Joint replacement surgery for elbow tumours: a systematic review of outcomes.

Authors:  Gopikanthan Manoharan; Robert W Jordan; Georgios Orfanos; Manikandar S Cheruvu; Paul Cool; Stuart M Hay
Journal:  Shoulder Elbow       Date:  2021-05-20

6.  [The Guepar total elbow arthroplasty].

Authors:  J Y Alnot; B Augereau; P Bellemère
Journal:  Int Orthop       Date:  1994-04       Impact factor: 3.075

7.  Does total humeral endoprosthetic replacement provide reliable reconstruction with preservation of a useful extremity?

Authors:  Hazem Wafa; Krishna Reddy; Robert Grimer; Adesegun Abudu; Lee Jeys; Simon Carter; Roger Tillman
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

8.  Combined use of free vascularised fibula graft and extracorporeally irradiated osteochondral graft for osteosarcoma of the proximal ulna.

Authors:  Akira Ogose; Tetsuo Hotta; Minoru Shibata; Hiroyuki Kawashima; Naoto Endo
Journal:  Oncol Lett       Date:  2010-01-01       Impact factor: 2.967

9.  Osteoarticular and total elbow allograft reconstruction with severe bone loss.

Authors:  F Daniel Kharrazi; Benjamin T Busfield; Daniel S Khorshad; Francis J Hornicek; Henry J Mankin
Journal:  Clin Orthop Relat Res       Date:  2008-01-03       Impact factor: 4.176

10.  Outcome of surgical management of bony metastases to the humerus and shoulder girdle: a retrospective analysis of 93 patients.

Authors:  Duy M Thai; Yasuyuki Kitagawa; Peter Fm Choong
Journal:  Int Semin Surg Oncol       Date:  2006-03-01
View more