Literature DB >> 3611169

Biodegradable internal fixation for malleolar fractures. A prospective randomised trial.

O Böstman, S Vainionpää, E Hirvensalo, A Mäkelä, K Vihtonen, P Törmälä, P Rokkanen.   

Abstract

Fifty-six patients with displaced malleolar fractures had open reduction and fixation of the fracture fragments using, by random selection, either biodegradable implants or metal AO plates and screws. The cylindrical biodegradable implants were made of polylactide-glycolide copolymer (polyglactin 910). The complications, radiographic results and functional recovery were studied prospectively. After follow-up of at least one year, no significant differences emerged in the complication rate or in the results of treatment between the two methods of fixation. Because of the advantage of avoiding the need to remove metal fixation after union, we now use biodegradable internal fixation routinely to treat displaced malleolar fractures.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3611169

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  19 in total

1.  Complications of bioresorbable fixation systems in pediatric neurosurgery.

Authors:  Cherukuri Ravi Kumar; Sandeep Sood; Steven Ham
Journal:  Childs Nerv Syst       Date:  2004-07-29       Impact factor: 1.475

2.  Strength retention of drawn self-reinforced polyglycolide rods and fixation properties of the distal femoral osteotomies with these rods. An experimental study on rats.

Authors:  Harri Pihlajamäki; E Antero Mäkelä; Nureddin Ashammakhi; Janne Viljanen; Hannu Pätiälä; Pentti Rokkanen; Timo Pohjonen; Pertti Törmälä; Antti Joukainen
Journal:  J Mater Sci Mater Med       Date:  2002-04       Impact factor: 3.896

3.  Absorbable polyglycolide pins in fixation of displaced fractures of the radial head.

Authors:  E Hirvensalo; O Böstman; P Rokkanen
Journal:  Arch Orthop Trauma Surg       Date:  1990       Impact factor: 3.067

4.  Wound infections associated with absorbable or metallic devices used in the fixation of fractures, arthrodeses and osteotomies.

Authors:  I Sinisaari; H Pätiälä; O Böstman; E A Mäkelä; E Hirvensalo; E K Partio; P Törmälä; P Rokkanen
Journal:  Eur J Orthop Surg Traumatol       Date:  1995-12

5.  Intramedullary fixation of cortical bone osteotomies with self-reinforced polylactic rods in rabbits.

Authors:  A Majola; S Vainionpää; K Vihtonen; J Vasenius; P Törmälä; P Rokkanen
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

6.  The use of biodegradable implants in the fixation of small animal cancellous bone fractures.

Authors:  P Axelson; J Räihä; K Sittnikow; K Skutnabb; M Mero; S Vainionpää; P Törmälä; P Rokkanen
Journal:  Acta Vet Scand       Date:  1988       Impact factor: 1.695

7.  Tissue-implant interface at an absorbable fracture fixation plug made of polylactide in cancellous bone of distal rabbit femur.

Authors:  H Pihlajamäki; O Böstman; M Manninen; U Päivärinta; P Rokkanen
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

Review 8.  Biodegradable implants in traumatology: a review on the state-of-the-art.

Authors:  G O Hofmann
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

9.  Fibrous wound repair associated with biodegradable poly-L/D-lactide copolymer implants: study of the expression of tenascin and cellular fibronectin.

Authors:  R Kontio; A Salo; R Suuronen; C Lindqvist; J H Meurman; I Virtanen
Journal:  J Mater Sci Mater Med       Date:  1998-10       Impact factor: 3.896

10.  Shear-load carrying capacities of the distal rat femora after osteotomy fixed with self-reinforced polyglycolic acid and poly-L-lactic acid pins.

Authors:  Pia Nordström; Timo Pohjonen; Pertti Törmälä; Pentti Rokkanen
Journal:  J Mater Sci Mater Med       Date:  2002-01       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.