| Literature DB >> 36110601 |
Sunil K Vaddamanu1, Rajesh Vyas1, Kumari Kavita2, R Sushma3, Akhila S Aboobacker4, Arti Dixit5, Amit Kumar6.
Abstract
Background: The erbium-doped yttrium aluminium garnet (Er:YAG) laser has been revealed to effectively ablate dental hard tissues, and its utilisation to caries eradication and cavity preparation is envisaged. Nevertheless, only a limited research has been performed on the Er:YAG laser's capacity to treat caries. Aim andEntities:
Keywords: Caries removal; Er:YAG laser; cavity preparation; dentin; root caries
Year: 2022 PMID: 36110601 PMCID: PMC9469416 DOI: 10.4103/jpbs.jpbs_95_22
Source DB: PubMed Journal: J Pharm Bioallied Sci ISSN: 0975-7406
Comparison of the time required for caries removal between the Er:YAG laser and bur therapies
| Time(s) | |||
|---|---|---|---|
|
| |||
| Sample no. | Lasera | Burb | Laser/bur ratio |
| 1 | 135 | 89 | 1.91 |
| 2 | 157 | 87 | 1.80 |
| 3 | 173 | 118 | 1.47 |
| 4 | 257 | 49 | 5.24 |
| 5 | 86 | 62 | 1.39 |
| 6 | 297 | 131 | 2.27 |
| 7 | 124 | 93 | 1.33 |
| 8 | 418 | 85 | 4.92 |
| 9 | 39 | 24 | 1.63 |
| 10 | 63 | 37 | 1.65 |
| 11 | 160 | 69 | 2.32 |
| 12 | 17 | 18 | 0.94 |
| 13 | 55 | 22 | 2.50 |
| 14 | 142 | 34 | 3.74 |
| 15 | 79 | 22 | 3.59 |
| 16 | 108 | 25 | 4.32 |
| 17 | 296 | 47 | 6.30 |
| 18 | 57 | 25 | 2.29 |
| 19 | 54 | 19 | 2.84 |
| 20 | 86 | 40 | 2.15 |
| 21 | 113 | 41 | 2.63 |
| 22 | 94 | 38 | 2.47 |
| 23 | 63 | 26 | 2.42 |
| 24 | 199 | 47 | 4.21 |
| 25 | 147 | 39 | 3.77 |
| Mean±SD | 137.0±95.2 | 51.6±31.7 | 2.80±1.37 |
Significance: P<0.0001. a Irradiation conditions: 145 mJ/pulse (51.3 J/cm2 /pulse), 10 pps, under water spray. b Round steel burs mounted on a micromotor at 10,000 rpm
Comparison of KHN of the treated cavity floor dentin between the Er:YAG laser and bur therapies
| KHNa(kg/mm2) | ||
|---|---|---|
|
| ||
| Sample no. | Laserb | Burc |
| 1 | 65.4d | 63.4 |
| 2 | 47.9 | 47.2 |
| 3 | 51.2d | 52.9 |
| 4 | 52.6 | 49.9d |
| 5 | 58.5 | 53.8d |
| 6 | 57.6 | 50.5d |
| 7 | 53.1d | 63.1 |
| 8 | 39.9d | 49.4 |
| 9 | 41.6d | 45.5 |
| 10 | 37.8 | 37.3d |
| Mean±SD | 50.4±8.5 | 51.7±8.1 |
Significance: NS. a Application of a 50 g load for 15 s. b Irradiation conditions: 145 mJ/pulse (51.3 J/cm2/pulse), 10 pps, under water spray. c Round steel burs mounted on a micromotor at 10,000 rpm. d The lower of the two KHN values for each sample