Literature DB >> 3610200

An externally powered, multichannel, implantable stimulator for versatile control of paralyzed muscle.

B Smith, P H Peckham, M W Keith, D D Roscoe.   

Abstract

Entities:  

Mesh:

Year:  1987        PMID: 3610200     DOI: 10.1109/tbme.1987.325979

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


× No keyword cloud information.
  35 in total

1.  Design of low-cost general purpose microcontroller based neuromuscular stimulator.

Authors:  S Koçer; M Rahmi Canal; I Güler
Journal:  J Med Syst       Date:  2000-04       Impact factor: 4.460

2.  Computer-based test-bed for clinical assessment of hand/wrist feed-forward neuroprosthetic controllers using artificial neural networks.

Authors:  J L Luján; P E Crago
Journal:  Med Biol Eng Comput       Date:  2004-11       Impact factor: 2.602

3.  Injectable microstimulator for functional electrical stimulation.

Authors:  G E Loeb; C J Zamin; J H Schulman; P R Troyk
Journal:  Med Biol Eng Comput       Date:  1991-11       Impact factor: 2.602

4.  An implanted upper-extremity neuroprosthesis using myoelectric control.

Authors:  Kevin L Kilgore; Harry A Hoyen; Anne M Bryden; Ronald L Hart; Michael W Keith; P Hunter Peckham
Journal:  J Hand Surg Am       Date:  2008-04       Impact factor: 2.230

5.  Restoring voluntary grasping function in individuals with incomplete chronic spinal cord injury: pilot study.

Authors:  Naaz Kapadia; Vera Zivanovic; Milos R Popovic
Journal:  Top Spinal Cord Inj Rehabil       Date:  2013

6.  Funktionelle Elektrostimulation Paraplegischer Patienten.

Authors:  Helmut Kern
Journal:  Eur J Transl Myol       Date:  2014-07-08

7.  Walking after incomplete spinal cord injury with an implanted neuromuscular electrical stimulation system and a hinged knee replacement: a single-subject study.

Authors:  Nathaniel S Makowski; Lisa M Lombardo; Kevin M Foglyano; Rudi Kobetic; Gilles Pinault; Stephen M Selkirk; Ronald J Triolo
Journal:  Spinal Cord Ser Cases       Date:  2020-09-15

8.  Toronto rehabilitation institute-hand function test: assessment of gross motor function in individuals with spinal cord injury.

Authors:  Naaz Kapadia; Vera Zivanovic; Molly Verrier; Milos R Popovic
Journal:  Top Spinal Cord Inj Rehabil       Date:  2012

9.  Semiparametric Identification of Human Arm Dynamics for Flexible Control of a Functional Electrical Stimulation Neuroprosthesis.

Authors:  Eric M Schearer; Yu-Wei Liao; Eric J Perreault; Matthew C Tresch; William D Memberg; Robert F Kirsch; Kevin M Lynch
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2016-02-29       Impact factor: 3.802

10.  Tension and fatigue behavior of 316LVM 1x7 multi-strand cables used as implantable electrodes.

Authors:  John J Lewandowski; Ravikumar Varadarajan; Brian Smith; Chris Tuma; Mostafa Shazly; Luciano O Vatamanu
Journal:  Mater Sci Eng A Struct Mater       Date:  2008-07-15       Impact factor: 5.234

View more