ANALYSIS OF THE MECHANICAL BEHAVIOR OF THE POSTERIOR CRUCIATE LIGAMENT IN A PORCINE MODEL.

Rodrigo Ribeiro Pinho Rodarte1,2,3, João Antônio Matheus Guimarães2, Brenno Tavares Duarte3, Paulo Pedro Kenedi3, William Ribeiro Pinho4.   

Abstract

Introduction: The knee has shown a significant increase in the frequency of injury due to sports practice. This increase and the improvement of surgical techniques of ligament reconstruction have led to a greater indication of this treatment to achieve a function close to normal. Objective: To conduct a preliminary analysis of the ligament behavior.
Methods: The study consisted of the validation of an anatomical model of the pig, in which five models were subjected to mechanical tests. The data on the loads of the in situ model and the strains of the posterior cruciate ligament were collected.
Results: The analysis of the tensile load showed, at first, a nonlinear increase in stresses. Subsequently, the pig's knee showed a relatively linear intermediate response until failure around 1,200 N. Strain × time showed a response of the posterior cruciate ligament, which also has a relatively linear response.
Conclusion: We observed a linear behavior in the range of 1,000 to 5,000 microstrains in the strain of the posterior cruciate ligament. We suggest further studies to understand knee ligaments regarding their behavior in their function. Level of Evidence IV, Biomechanical Study.

Entities:  

Keywords:  Ligaments; Mechanical Stress; Tensile Strength

Year:  2022        PMID: 36092176      PMCID: PMC9425957          DOI: 10.1590/1413-785220223004e236261

Source DB:  PubMed          Journal:  Acta Ortop Bras        ISSN: 1413-7852            Impact factor:   0.683


INTRODUCTION

The knee is one of the body joints most vulnerable to trauma, which has been occurring more frequently in recent years due to sports practice. )-( This increase and improvement of surgical ligament reconstruction techniques have led to a greater indication of this treatment to achieve a function close to normal. The understanding of the behavior of knee structures regarding the tensile loads can allow to understand its physiological behavior to create new strategies to improve the result and choose the best graft for ligament reconstruction. The costs of ligament revision surgery and the scarcity of options as revisions are conducted may be factors that worry knee surgeons and managers. The concern with the quality of the reconstruction has made the researchers analyze the different points that can influence the result, such as new fixation devices, types of graft and other techniques that improve the result. The knee is a synovial diartrodial joint and some animals are used to simulate and reproduce surgical techniques, such as cattle and pigs, which can be widely used for training of surgeries and techniques. )-( Mechanical tests to understand the behavior of materials can be performed as tensile and compression tests. We used tensile loads to evaluate the ligament structures to observe the stress in the specimens and the strain over time. The lack of information in the tested ligament structures and in the behaviors of the in situ ligament, the performance of destructive and in vitro tests, allow a distributed analysis of the load of ligament failure as well as the strain behavior over time. For studies to develop new techniques, the National Health Council established in Resolution 1 of 07/15/1988, Decree 93,933 of 01/1987, Chapter II, Article 5, Item II, that: “Research in human beings must be based on previous experimental research conducted in animals”. Our study aimed to perform a preliminary analysis of the ligament behavior (posterior cruciate ligament) regarding the imposed tensile loads and their behavior by measuring their strains.

MATERIALS AND METHODS

The study consisted of the validation of an anatomical model of the pig’s knee, in which five knee models of young pigs without reconstruction were subjected to mechanical tests on the Instron device, with the extended knee being subjected to increasing tensile stress forces until the final failure of these models in vitro. The study was conducted in partnership with the Instituto Nacional de Traumatologia e Ortopedia, Universidade de Valença and Centro Federal de Educação Tecnológica Celso Suckow da Fonseca (CEFET/RJ) and the samples were provided by the animal room of the Universidade de Valença, respecting ethical standards to use the animals. The anatomy of the pig’s knee is essential because it is one of the joints significantly similar to the human being’s, being a synovial diartrodial joint used as an anatomical model for experimental studies and surgical training. The models were dissected keeping the four main knee ligaments 13.5 cm away from the articular surface of the femoral and tibial knee. A 6-mm cross-sectional hole was performed in the proximal (femur) and distal (tibia) segment and were kept in a refrigerator of −80°C after removal. On the day of the experiment, they were removed from the refrigerator five hours before the test and wrapped in gauze with 0.9% physiological saline. They were subjected to destructive tests, until the failure of the specimens, at room temperature in an air-conditioned room (22°C). The anatomical models were thawed according to what was planned, keeping the four main knee ligaments to subject them to mechanical testing. Five young pigs were evaluated to observe the ligament behavior and regarding the tensile load of the knees. A displacement of 3 mm/minute was imposed. Strain gages were placed, which are transducers capable of measuring mechanical strains in specimens, in posterior cruciate ligaments due to possible access to the extended knee. Then the data on the loads of the in situ model and the strains of the posterior cruciate ligament were collected from the information of the strain gages. The strain of the posterior cruciate ligament was observed during the failure test of the specimens (Figure 1).
Figure 1

Image with posterior view of the knee structures (left) and of the anatomical model attached to the Instron with strain gage glued to the posterior cruciate ligament (right).

The results were obtained and tables were generated with descriptive numerical values and load × displacement and strain × time graphs.

RESULTS

We observed the posterior cruciate ligament by analyzing the knee behavior and the tensile loads, and we found a linear behavior when measuring the strain with the strain gage. In the analysis of the tensile load, the load × extension graph showed, at first, an accommodation and a nonlinear increase in stresses. Subsequently, it showed a mean relatively linear intermediate response of the pig’s knee until failure around 1,200 N (Figure 2).
Figure 2

Load × displacement.

The load was apparently redistributed by other structures after failure, leaving some remaining residual strength. A relatively large displacement was imposed before the failure was noticed. The strain × time graph shows the response of the posterior cruciate ligament, which also has a relatively linear response between 1,000 and 5,000 microstrains (Figure 3).
Figure 3

Strain × time Graph.

DISCUSSION

The stability of the knee and its function depends on the perfect ligament action, and the reconstruction requires that the ligaments behave appropriately due to the loads imposed on it. The knee is a joint that is subjected to compressive and tensile forces. The tensile forces request the ligament structures, which show complex behavior, different from the elastic, viscous or rigid behavior, and may show different behaviors depending on the applied load and time. The reconstructions of ligament structures are frequently analyzed to understand the behavior of fixations and what would be the best fixation material. However, ligament behavior is essential to propose the best techniques, types of graft and fixation materials. The reconstruction seeks more rigid systems to reduce eventual translations that may arise in the postoperative period, but accommodations may arise over time. Some studies analyze in 3D models as if they had an elastic or rigid behavior in studies of graft extraction analysis, disregarding a viscoelastic behavior either of the tendon used as a graft or of the remaining ligaments. Galbusera et al. affirms the importance of researchers who perform 3D simulations to consider the anisotropic and nonlinear behavior of ligament and tendon structures. In our study, the posterior cruciate ligament showed a relatively linear behavior in the intermediate loads during the imposed load. The use of strain gages allowed to understand the strain behavior of the analyzed material, and in the case of musculoskeletal tissues they allow to understand this behavior and the choice of graft to better replace the injured structure. The limitation of our study is that the analyzed structure is an in situ structure and the complexity of the redistribution of forces and stresses must be considered in the evaluation, thus, in vitro studies with isolated biomechanical tests of ligaments are necessary. The strength of this study is the extraction of numerical values and data using strain gages to obtain new information, which might be the vanguard for use in musculoskeletal tissue tests.

CONCLUSION

Our study observed the linear behavior from 1,000 to 5,000 microstrains in the strain of the posterior cruciate ligament during the in situ displacement of the knee joint. We suggest further studies to understand knee ligaments regarding their behavior in knee function.
  14 in total

1.  Stress relaxation and recovery in tendon and ligament: experiment and modeling.

Authors:  Sarah E Duenwald; Ray Vanderby; Roderic S Lakes
Journal:  Biorheology       Date:  2010       Impact factor: 1.875

2.  Comparison between bovine bone and titanium interference screws for implant fixation in ACL reconstruction: a biomechanical study.

Authors:  Turgay Efe; Joscha Bauer; Silke Herdrich; Leo Gotzen; Bilal Farouk El-Zayat; Jan Schmitt; Markus Dietmar Schofer
Journal:  Arch Orthop Trauma Surg       Date:  2010-01-12       Impact factor: 3.067

3.  Tension degradation of anterior cruciate ligament grafts with dynamic flexion-extension loading: a biomechanical model in porcine knees.

Authors:  Jens Dargel; Jürgen Koebke; Gert-Peter Brüggemann; Dietmar Pennig; Rüdiger Schmidt-Wiethoff
Journal:  Arthroscopy       Date:  2009-08-22       Impact factor: 4.772

4.  Epidemiology of Injuries in High School Football: Does School Size Matter?

Authors:  Harold King; Stephen Campbell; Makenzie Herzog; David Popoli; Andrew Reisner; John Polikandriotis
Journal:  J Phys Act Health       Date:  2014-10-20

5.  Biomechanical evaluation of PCL reconstruction with suture augmentation.

Authors:  John A Grotting; Trevor J Nelson; Michael B Banffy; Dheeraj Yalamanchili; Sam A Eberlein; Jorge Chahla; Melodie F Metzger
Journal:  Knee       Date:  2020-02-01       Impact factor: 2.199

6.  Review of anterior cruciate ligament reconstruction cost variance within a regional health care system.

Authors:  Noah Archibald-Seiffer; John C Jacobs; Charles Saad; David S Jevsevar; Kevin G Shea
Journal:  Am J Sports Med       Date:  2015-04-21       Impact factor: 6.202

7.  The epidemiology of US high school basketball injuries, 2005-2007.

Authors:  Laurel A Borowski; Ellen E Yard; Sarah K Fields; R Dawn Comstock
Journal:  Am J Sports Med       Date:  2008-09-02       Impact factor: 6.202

8.  Epidemiology of knee injuries among boys and girls in US high school athletics.

Authors:  Jay G Ingram; Sarah K Fields; Ellen E Yard; R Dawn Comstock
Journal:  Am J Sports Med       Date:  2008-03-28       Impact factor: 6.202

Review 9.  Material models and properties in the finite element analysis of knee ligaments: a literature review.

Authors:  Fabio Galbusera; Maren Freutel; Lutz Dürselen; Marta D'Aiuto; Davide Croce; Tomaso Villa; Valerio Sansone; Bernardo Innocenti
Journal:  Front Bioeng Biotechnol       Date:  2014-11-17

Review 10.  Anteromedial versus transtibial technique in single-bundle autologous hamstring ACL reconstruction: a meta-analysis of prospective randomized controlled trials.

Authors:  Haitao Chen; Kai Tie; Yongjian Qi; Bin Li; Biao Chen; Liaobin Chen
Journal:  J Orthop Surg Res       Date:  2017-11-07       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.