Literature DB >> 36061370

Plasma Kidney Injury Molecule-1 in Systemic Lupus Erythematosus: Discordance Between ELISA and Proximity Extension Assay.

Insa M Schmidt1, Mia R Colona1, Anand Srivastava2, Guanghao Yu1, Venkata Sabbisetti3, Joseph V Bonventre3, Sushrut S Waikar1.   

Abstract

Entities:  

Keywords:  ELISA; Olink; plasma kidney injury molecule-1; proteomics

Year:  2022        PMID: 36061370      PMCID: PMC9437607          DOI: 10.1016/j.xkme.2022.100496

Source DB:  PubMed          Journal:  Kidney Med        ISSN: 2590-0595


× No keyword cloud information.
To the Editor: Oligonucleotide-labeled antibodies (Olink, Olink Proteomics) and aptamers (SomaScan, SomaLogic) are increasingly used in biomarker discovery and research. However, few studies have compared the protein levels measured on proteomics platforms with those measured using conventional immunoaffinity assays.1, 2, 3, 4, 5 This may be especially relevant in the setting of autoimmune diseases, such as systemic lupus erythematosus (SLE), where anti–double-stranded DNA (anti-dsDNA) antibodies could interfere with immunoassay technologies that use oligonucleotide-based antibodies (Olink) or aptamers (SomaScan). In this study, we compared measurements of plasma kidney injury molecule-1 (KIM-1), a sensitive marker of tubular injury with prognostic value,, across 2 different immunoassay technologies in patients with and without SLE. We measured plasma KIM-1 levels in 446 individuals enrolled in the Boston Kidney Biopsy Cohort, a prospective, observational cohort study of patients with chronic kidney disease (Item S1), using the microbead-based sandwich enzyme-linked immunosorbent assay (ELISA) and a proximity extension assay (Olink). The proximity extension assay uses oligonucleotide-labeled antibodies that bind to the target protein. The measurements and assay performance of both ELISA and the Olink platform in the Boston Kidney Biopsy Cohort were described previously in detail., Using Spearman correlation coefficients, we investigated differences in plasma KIM-1 measurements between the 2 assays in individuals with and without SLE and in individuals with negative versus positive anti-dsDNA levels (assay reference range, ≤25 vs >25 IU/mL). The corresponding 95% confidence intervals (CIs) were reported as bias-corrected and accelerated bootstrap estimates. Sixty-eight Boston Kidney Biopsy Cohort participants had SLE and were compared with 378 individuals with diseases other than SLE (Table S1). The mean ages were 39 ± 15 and 55 ± 16 years, the mean estimated glomerular filtration rates were 85 ± 37 and 52 ± 33 mL/min/1.73 m2, and the median proteinurias (interquartile range) were 1.5 (0.7-3.2) and 1.7 (0.4-4.2) g/g creatinine in individuals with and without SLE, respectively. Eighty-seven percent of individuals with SLE were women and 46% of those without SLE were women. Among those with SLE, 62% had proliferative and 27% had nonproliferative histopathologic lesions in the kidneys. Spearman’s ρ between plasma KIM-1 measurements from both assays in the entire cohort was 0.89 (95% CI, 0.85-0.92; P < 0.001). Spearman’s ρ was 0.69 (95% CI, 0.47-0.82; P < 0.001) in individuals with SLE, and Spearman’s ρ was 0.90 (95% CI, 0.85-0.93; P < 0.001) in individuals with diseases other than SLE (Fig 1). Forty-three individuals with SLE had available anti-dsDNA levels measured using the chemiluminescent QUANTA Flash dsDNA assay (Werfen). The correlation between the 2 assays was lower in 34 individuals with anti-dsDNA antibody levels >25 IU/mL (ρ = 0.70; 95% CI, 0.37-0.88; P < 0.001) than in 9 individuals with anti-dsDNA levels ≤25 IU/mL (ρ = 0.92; 95% CI, 0.68-1.0; P = 0.001).
Figure 1

Correlation between plasma kidney injury molecule-1 (KIM-1) measurements using enzyme-linked immunosorbent assay (ELISA) and a proximity extension assay (Olink) according to systemic lupus erythematosus (SLE) status. Plasma KIM-1 (Olink) values are expressed as normalized protein expression values on a log2 scale. Plasma KIM-1 (ELISA) values were measured in pg/mL and log2-transformed.

Correlation between plasma kidney injury molecule-1 (KIM-1) measurements using enzyme-linked immunosorbent assay (ELISA) and a proximity extension assay (Olink) according to systemic lupus erythematosus (SLE) status. Plasma KIM-1 (Olink) values are expressed as normalized protein expression values on a log2 scale. Plasma KIM-1 (ELISA) values were measured in pg/mL and log2-transformed. In this study, we found differences in the concordance of plasma KIM-1 measurements by proximity extension assay versus ELISA according to SLE status. Few studies have compared assay specificity and correlation between different assay technologies.1, 2, 3, 4, 5 In a prior study, correlations between ELISA and SomaScan aptamer–based assays for multiple proteins ranged from high for some proteins (eg, C-reactive protein) to none (eg, platelet endothelial cell adhesion molecule-1).2 In a recent study that compared soluble urokinase plasminogen activator receptor levels measured by conventional ELISA with the Olink and SomaScan platforms in 3 different cohorts, assay correlations varied widely across the cohorts (Spearman’s ρ = 0.3-0.8). Soluble urokinase plasminogen activator receptor had a weaker magnitude of association with adverse clinical outcomes when measured on the proteomics platforms compared with ELISA. Although cross-reactivity, epitope availability, and negative cooperative binding could all influence the concordance between assay technologies, it is possible that autoantibodies (eg, anti-dsDNA antibodies, which can bind to diverse DNA structures and nucleoprotein complexes, and may have DNA-related catalytic activity) interfere with measurements dependent on proximity-based oligonucleotide amplicons used in the Olink platform. Although our sample size of individuals with available anti-dsDNA levels was small, our results showing lower correlation with higher anti-dsDNA levels highlight a potential limitation to the use of oligonucleotide-based assay technologies in patients with diseases characterized by the presence of autoantibodies. More broadly, our results emphasize the possibility of disease-specific interference phenomena for biomarker assays and the importance of cross-platform validation studies.
  9 in total

1.  Bootstrap standard error and confidence intervals for the correlation corrected for range restriction: a simulation study.

Authors:  Wai Chan; Daniel W-L Chan
Journal:  Psychol Methods       Date:  2004-09

2.  Comparison of Proteomic Assessment Methods in Multiple Cohort Studies.

Authors:  Laura M Raffield; Hong Dang; Katherine A Pratte; Sean Jacobson; Lucas A Gillenwater; Elizabeth Ampleford; Igor Barjaktarevic; Patricia Basta; Clary B Clish; Alejandro P Comellas; Elaine Cornell; Jeffrey L Curtis; Claire Doerschuk; Peter Durda; Claire Emson; Christine M Freeman; Xiuqing Guo; Annette T Hastie; Gregory A Hawkins; Julio Herrera; W Craig Johnson; Wassim W Labaki; Yongmei Liu; Brett Masters; Michael Miller; Victor E Ortega; George Papanicolaou; Stephen Peters; Kent D Taylor; Stephen S Rich; Jerome I Rotter; Paul Auer; Alex P Reiner; Russell P Tracy; Debby Ngo; Robert E Gerszten; Wanda K O'Neal; Russell P Bowler
Journal:  Proteomics       Date:  2020-06       Impact factor: 3.984

3.  Reproducibility and Variability of Protein Analytes Measured Using a Multiplexed Modified Aptamer Assay.

Authors:  Adrienne Tin; Bing Yu; Jianzhong Ma; Kunihiro Masushita; Natalie Daya; Ron C Hoogeveen; Christie M Ballantyne; David Couper; Casey M Rebholz; Morgan E Grams; Alvaro Alonso; Thomas Mosley; Gerardo Heiss; Peter Ganz; Elizabeth Selvin; Eric Boerwinkle; Josef Coresh
Journal:  J Appl Lab Med       Date:  2019-01-22

4.  Circulating Plasma Biomarkers in Biopsy-Confirmed Kidney Disease.

Authors:  Insa M Schmidt; Suraj Sarvode Mothi; Parker C Wilson; Ragnar Palsson; Anand Srivastava; Ingrid F Onul; Zoe A Kibbelaar; Min Zhuo; Afolarin Amodu; Isaac E Stillman; Helmut G Rennke; Benjamin D Humphreys; Sushrut S Waikar
Journal:  Clin J Am Soc Nephrol       Date:  2021-11-10       Impact factor: 8.237

5.  Assay-related differences in SuPAR levels: implications for measurement and data interpretation.

Authors:  Alexi Vasbinder; Laura Marie Raffield; Yan Gao; Gunnar Engstrom; Arshed Ali Quyyumi; Alexander Paul Reiner; Jochen Reiser; Salim Salim Hayek
Journal:  J Nephrol       Date:  2022-05-14       Impact factor: 4.393

Review 6.  Kidney Injury Molecule-1 (KIM-1): a specific and sensitive biomarker of kidney injury.

Authors:  Joseph V Bonventre
Journal:  Scand J Clin Lab Invest Suppl       Date:  2008

7.  Comparison of proteomic methods in evaluating biomarker-AKI associations in cardiac surgery patients.

Authors:  Richard X Liu; Heather R Thiessen-Philbrook; Ramachandran S Vasan; Josef Coresh; Peter Ganz; Joseph V Bonventre; Paul L Kimmel; Chirag R Parikh
Journal:  Transl Res       Date:  2021-07-31       Impact factor: 7.012

Review 8.  Anti-double Stranded DNA Antibodies: Origin, Pathogenicity, and Targeted Therapies.

Authors:  Xiaoyu Wang; Yumin Xia
Journal:  Front Immunol       Date:  2019-07-17       Impact factor: 7.561

9.  Plasma Kidney Injury Molecule 1 in CKD: Findings From the Boston Kidney Biopsy Cohort and CRIC Studies.

Authors:  Insa M Schmidt; Anand Srivastava; Venkata Sabbisetti; Gearoid M McMahon; Jiang He; Jing Chen; John W Kusek; Jonathan Taliercio; Ana C Ricardo; Chi-Yuan Hsu; Paul L Kimmel; Kathleen D Liu; Theodore E Mifflin; Robert G Nelson; Ramachandran S Vasan; Dawei Xie; Xiaoming Zhang; Ragnar Palsson; Isaac E Stillman; Helmut G Rennke; Harold I Feldman; Joseph V Bonventre; Sushrut S Waikar
Journal:  Am J Kidney Dis       Date:  2021-06-25       Impact factor: 8.860

  9 in total