Comparison of the hydrophobic-grid membrane filter procedure and standard methods for coliform analysis of water.

A E McDaniels, R H Bordner, J R Menkedick, C I Weber.   

Abstract

The hydrophobic-grid membrane filter (HGMF) has been proposed as an alternate method to the standard membrane filter (MF) procedure for the detection and enumeration of coliforms from water. Eight samples of nonchlorinated wastewater effluents were analyzed by the HGMF, standard MF, and tube fermentation most-probable-number methods for fecal coliforms, and eight samples each of polluted surface and dosed drinking waters were analyzed by the same methods for total coliforms. The drinking waters were dosed with coliforms and other heterotrophs concentrated from nonchlorinated domestic wastewater and treated with chlorine to reduce the numbers of organisms and simulate stress caused by chlorination. Statistical analyses determined that recoveries of fecal coliforms were significantly higher by the filtration methods for the nonchlorinated domestic wastewaters but not for the other waters. The results also indicated that recoveries of fecal and total coliforms did not differ significantly when either MFs or HGMFs were used. Total coliform results obtained with HGMFs having greater than 100 positive grid cells were significantly more precise than estimates obtained by the standard MF method only for polluted surface waters.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3606086      PMCID: PMC203801          DOI: 10.1128/aem.53.5.1003-1009.1987

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  5 in total

1.  Enumeration of high numbers of bacteria using hydrophobic grid-membrane filters.

Authors:  A N Sharpe; G L Michaud
Journal:  Appl Microbiol       Date:  1975-10

2.  Improved membrane filter method for fecal coliform analysis.

Authors:  R E Rose; E E Geldreich; W Litsky
Journal:  Appl Microbiol       Date:  1975-04

3.  Membrane filtration of food suspensions.

Authors:  A N Sharpe; P I Peterkin; I Dudas
Journal:  Appl Environ Microbiol       Date:  1979-01       Impact factor: 4.792

4.  Colony counting on hydrophobic grid-membrane filters.

Authors:  A N Sharpe; M P Diotte; I Dudas; S Malcolm; P I Peterkin
Journal:  Can J Microbiol       Date:  1983-07       Impact factor: 2.419

5.  Hydrophobic grid-membrane filters: new approach to microbiological enumeration.

Authors:  A N Sharpe; G L Michaud
Journal:  Appl Microbiol       Date:  1974-08
  5 in total
  1 in total

1.  An enzyme-linked immunosorbent assay-based isolation procedure for verotoxigenic Escherichia coli.

Authors:  D G Milley; L H Sekla
Journal:  Appl Environ Microbiol       Date:  1993-12       Impact factor: 4.792

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.