| Literature DB >> 36053639 |
Kasem Seresirikachorn1, Warakorn Thiamthat2, Wararee Sriyuttagrai3, Ngamphol Soonthornworasiri4, Panisa Singhanetr5, Narata Yudtanahiran6, Thanaruk Theeramunkong7,8.
Abstract
PURPOSE: Computer vision syndrome (CVS) describes a group of eye and vision-related problems that result from prolonged digital device use. This study aims to assess the prevalence and associated factors of CVS among students during the lockdown resulting from the COVID-19 pandemic.Entities:
Keywords: Adolescent Health; COVID-19; Epidemiology; Information Technology; Ophthalmology
Mesh:
Year: 2022 PMID: 36053639 PMCID: PMC9184992 DOI: 10.1136/bmjpo-2022-001429
Source DB: PubMed Journal: BMJ Paediatr Open ISSN: 2399-9772
Demographic characteristics of participants and usage of electronic devices before the pandemic (N=2476)
| Demographic characteristics | N (%) |
| Mean age (years) ±SD | 15.52±1.66 (range 10–19) |
| Female | 1606 (64.9) |
| Grade | |
| 4–6 | 11 (0.4) |
| 7–9 | 781 (31.6) |
| 10–12 | 1684 (68) |
| Refractive status | |
| Emmetropia | 1180 (47.7) |
| Myopia | 1055 (42.6) |
| Hyperopia | 241 (9.7) |
| Glasses and contact lens (CL) use | |
| None | 1180 (47.7) |
| Glasses for myopia | 784 (31.7) |
| Glasses for hyperopia | 186 (7.5) |
| CL for myopia | 151 (6.1) |
| CL for hyperopia | 47 (1.9) |
| Glasses and CL for myopia | 120 (4.8) |
| Glasses and CL for hyperopia | 8 (0.3) |
| Most commonly used digital devices (pre-COVID-19) | |
| Mobile phone | 1341 (54.2) |
| Tablet | 454 (18.3) |
| Computer desktop | 436 (17.6) |
| Computer laptop | 216 (8.7) |
| Television | 29 (1.2) |
| Frequency of eye check-up | |
| None | 1054 (42.6) |
| Once every 2 years | 504 (20.4) |
| Once a year | 715 (28.9) |
| Twice a year | 203 (8.2) |
Comparison between duration of digital device usage per day before and during COVID-19 lockdown (N=2476)
| Duration of digital device usage per day | Before COVID-19 | During COVID-19 |
| ≤2 hours | 201 (8.1%) | 67 (2.7%) |
| 3–4 hours | 596 (24.1%) | 271 (21.9%) |
| 5–6 hours | 648 (26.2%) | 502 (20.3%) |
| 7–8 hours | 492 (19.9%) | 1109 (44.8%) |
| 9–10 hours | 401 (16.2%) | 480 (19.4%) |
| 11–12 hours | 49 (1.9%) | 16 (0.7%) |
| >12 hours | 89 (3.6%) | 31 (1.3%) |
|
| 6.13±2.8 | 10.53±2.99 |
The usage of electronic devices in online learning during COVID-19 lockdown (N=2476)
| Demographic characteristics | N (%) |
| Total hours of online learning | |
| ≤2 hours | 67 (2.7) |
| 3–4 hours | 271 (11) |
| 5–6 hours | 502 (20.3) |
| 7–8 hours | 1109 (44.8) |
| 9–10 hours | 480 (19.4) |
| >10 hours | 47 (1.8) |
| Device used for online learning | |
| Single device | 1486 (60) |
| Multiple device | 990 (40) |
| Mobile phone | 1174 (47.4) |
| Tablet | 1095 (44.2) |
| Computer desktop | 965 (39) |
| Computer laptop | 691 (27.9) |
| Television | 27 (1.1) |
| Environment | |
| Fan | 1272 (51.4) |
| Air conditioning | 1203 (48.6) |
| Protective instrument | |
| None | 413 (16.7) |
| Blue-coated glasses | 1172 (47.3) |
| Blue-coated film on digital devices | 680 (27.5) |
| Both blue-coated glasses and film on digital device | 211 (8.5) |
| Frequency of eye rest | |
| Never | 371 (15) |
| Every 15 min | 596 (24.1) |
| Every 30 min | 431 (17.4) |
| Every 45 min | 304 (12.3) |
| Every 1 hour | 427 (17.2) |
| Every ≥1 hour | 347 (14) |
| Distance of digital devices from eyes during online learning | |
| <40 cm | 943 (38.1) |
| 40–80 cm | 1260 (50.9) |
| >80 cm | 273 (11) |
| Back pain | 1880 (75.9) |
| Neck pain | 1687 (68.1) |
| Activity when resting | |
| Close eyes | 1144 (46.2) |
| Sleep | 1230 (49.7) |
| Look out | 822 (33.2) |
| Play games | 568 (22.9) |
| Use artificial tears | 271 (10.9) |
Figure 1The mean number of hours per day of online learning and total hours per day of digital device usage according to computer vision syndrome (CVS) severity.
Figure 2The percentage of frequency and severity of different eye symptoms of computer vision syndrome in students.
Multiple logistic regression showing the associated risk factors of CVS
| Factor | Univariate analysis | Multiple analysis | ||||
| Crude OR | 95% CI | P value | Adjusted OR | 95% CI | P value | |
| Age ≤15 | 2.34 | 1.63 to 3.36 | <0.001 |
|
|
|
| Female | 1.73 | 1.34 to 2.23 | <0.001 | 1.26 | 0.90 to 1.75 | 0.178 |
| Overall digital usage >6 hours | 7.41 | 5.52 to 9.96 | <0.001 |
|
|
|
| Online learning >5 hours | 7.99 | 6.07 to 10.53 | <0.001 |
|
|
|
| Refractive error | 1.35 | 1 to 02 to 1.79 | 0.035 |
|
|
|
| Refractive error | ||||||
| Myopia | 3.21 | 2.31 to 4.44 | <0.001 |
|
|
|
| Emmetropia | 3.19 | 2.21 to 4.60 | <0.001 |
|
|
|
| Hyperopia | Ref |
| ||||
| Fan | 2.55 | 1.86 to 3.48 | <0.001 | 1.2 | 0.81 to 1.81 | 0.362 |
| Non-protective device used | 1.82 | 1.19 to 2.79 | 0.006 | 1.07 | 0.66 to 1.73 | 0.793 |
| Protective device | ||||||
| Both | 4.62 | 2.90 to 7.38 | <0.001 | 0.66 | 0.39 to 1.11 | 0.118 |
| Blue-coated glasses | 3.36 | 2.52 to 4.49 | <0.001 | 1.19 | 0.71 to 1.99 | 0.508 |
| Blue-coated film | Ref | Ref | ||||
| Rest of over 45 min | 2.59 | 2.01 to 3.34 | <0.001 | 1.02 | 0.7 to 1.48 | 0.935 |
| Other digital devices used >2 hours | 2.22 | 1.73 to 2.85 | <0.001 | 0.89 | 0.61 to 1.28 | 0.52 |
| Distance from device <40 cm | 2.42 | 1.78 to 3.30 | <0.001 | 1.07 | 0.71 to 1.63 | 0.743 |
| Back pain | 2.84 | 2.12 to 3.80 | <0.001 |
|
|
|
| Neck pain | 2.59 | 1.94 to 3.46 | <0.001 |
|
|
|
| Multiple digital devices used | 3.6 | 2.76 to 4.70 | <0.001 |
|
|
|
| Non-use of artificial tears | 0.96 | 0.70 to 1.30 | 0.77 | 1.34 | 0.91 to 1.98 | 0.133 |
| Close eyes during online learning | 1.69 | 1.32 to 2.17 | <0.001 | 1.12 | 0.80 to 1.55 | 0.508 |
| Sleep during online learning | 2.12 | 1.64 to 2.74 | <0.001 | 1.29 | 0.93 to 1.79 | 0.135 |
| Laptop computer preference | 2.36 | 1.75 to 3.19 | <0.001 | 0.83 | 0.48 to 1.42 | 0.494 |
| Tablet preference | 2.27 | 1.77 to 2.92 | <0.001 | 0.86 | 0.51 to 1.45 | 0.568 |
| Television screen preference | 1.49 | 0.49 to 4.55 | 0.49 | 1.067 | 0.30 to 3.75 | 0.92 |
| Computer desktop preference | 1.37 | 1.07 to 1.77 | 0.016 | 1 | 0.61 to 1.66 | 0.987 |
| Mobile phone preference | 1.34 | 1.03 to 1.69 | 0.031 | 0.81 | 0.50 to 1.31 | 0.395 |
CVS, computer vision syndrome.