Konstantinos C Theodoropoulos1, Ioannis Felekos2, Aleem Khand1,3,4.
Abstract
Entities:
Year: 2022 PMID: 36051834 PMCID: PMC9421512 DOI: 10.5114/aic.2022.118819
Source DB: PubMed Journal: Postepy Kardiol Interwencyjnej ISSN: 1734-9338 Impact factor: 1.065
Figure 1A – Coronary angiogram, occluded left circumflex due to late stent thrombosis. B – Optical coherence tomography (OCT) demonstrating stent underexpansion and circumferential (360°) calcification behind the stent struts, extending around 0.5 mm in depth. C, D – “Dog-bone” appearance and residual waisting after aggressive NC balloon inflations. E – Repeat OCT run demonstrating an improved minimum stent area
Figure 2A – Inflation with a 3.5 mm NC balloon. B – Final angiographic result with TIMI III flow. C – Repeat OCT run confirming good stent expansion and a minimum stent area of around 4.75 mm2