Literature DB >> 36038236

Label-free electrochemical immunosensor for picomolar detection of the cervical cancer biomarker MCM5.

Ahmed Barhoum1, Robert J Forster2.   

Abstract

An immunosensor for label-free electrochemical detection of MiniChromosome Maintenance Protein 5, MCM5, a protein overexpressed in cervical cancer, based on a gold electrode is reported. The electrode was first modified with a submonolayer (capture layer) of 11-mercaptoundecanoic acid (11-MUA) and then activated with N-(3-dimethylaminopropyl)-N-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) to immobilize the capture antibody. The change in electrode surface properties (wettability) during the formation of the 11-MUA layers was determined using the static water contact angle (WCA). The binding of MCM5 antigens to the capture antibody was monitored by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) using 5 mM [Fe(CN)6]3-/4- in 0.1 M LiClO4(aq) as an electroactive probe. AC Impedance was used to measure charge transfer resistance (Rct), which reflects impeded electron transfer when the antigen is bound to the antibody functionalized surface. After exposing the antibody-functionalized surface to MCM5 antigens, Rct increases linearly with the logarithmic value of MCM5 antigen concentration, with a linear dynamic range of 10-6 to 10-11 g/mL, a correlation coefficient of 0.99, and a detection limit of 2.9 pM (10-11 g/mL). This excellent sensitivity was achieved with simple preparation steps and minimal reagent consumption, without the need for complicated procedures such as enzymatic amplification, fluorescent labeling, or nanoparticle modification.
Copyright © 2022 The Authors. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cancer biomarkers; Charge-transfer resistance; Cyclic voltammetry; Gold disk electrode; Impedance spectroscopy; MiniChromosome maintenance protein 5; Self-assembled monolayers

Mesh:

Substances:

Year:  2022        PMID: 36038236     DOI: 10.1016/j.aca.2022.340226

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.911


  2 in total

Review 1.  Current trends in COVID-19 diagnosis and its new variants in physiological fluids: Surface antigens, antibodies, nucleic acids, and RNA sequencing.

Authors:  Menna Mostafa; Ahmed Barhoum; Ekin Sehit; Hossam Gewaid; Eslam Mostafa; Mohamed M Omran; Mohga S Abdalla; Fatehy M Abdel-Haleem; Zeynep Altintas; Robert J Forster
Journal:  Trends Analyt Chem       Date:  2022-08-30       Impact factor: 14.908

2.  Non-Enzymatic Phenylboronic Acid-Based Optode Membrane for Glucose Monitoring in Serums of Diabetic Patients and in the Culture Medium of Human Embryos.

Authors:  Mohamed M Taha; Mahmoud S Rizk; Mohamed A Zayed; Fatehy M Abdel-Haleem; Ahmed Barhoum
Journal:  Sensors (Basel)       Date:  2022-09-21       Impact factor: 3.847

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.