| Literature DB >> 36034779 |
Yahdiana Harahap1,2, Steven Steven1, Herman Suryadi1.
Abstract
Cyclophosphamide (CP) is an anti-cancer alkylating prodrug, metabolized by CYP450 into its active metabolite 4-hydroxycyclophosphamide (4-OHCP). Its therapeutic effectiveness is determined by the 4-OHCP concentration. Several analytical methods in plasma and dried blood spots have been developed to analyze cyclophosphamide and 4-OHCP; however, there are many disadvantages. The objective of this study was to develop and validate the ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method by volumetric absorptive microsampling (VAMS) and 4-hydroxycyclophosphamide-d4 (4-OHCP-d4) as an internal standard. VAMS requires small sample volumes, and it is not affected by the hematocrit values; therefore, it is an efficient sampling method. The samples were derivatized with 5 μL semicarbazide hydrochloride (SCZ) and 25 μL of the resulting 4-OHCP-SCZ; 4-OHCP-d4-SCZ derivatives were absorbed by VAMS and extracted by protein precipitation. The optimum conditions were obtained using the Waters Acquity® UPLC BEH C18 (2.1 × 100 mm; 1.7 μm) column; flow rate 0.15 ml/min; mobile phase 0.01% formic acid and methanol; gradient elution mode for 6 min by positive electrospray ionization; and multiple reaction monitoring of m/z 260.7 > 140.0 for CP, 333.7 > 221.0 for 4-OHCP-SCZ, and 337.7 > 225.1 for 4-OHCP-d4-SCZ. The method met the validation requirements set by the FDA. The cyclophosphamide LLOQ value was 5 ng/mL, and the calibration curve range was 5-60,000 ng/ml. Furthermore, the 4-OHCP LLOQ value was 2.5 ng/ml, and the calibration curve range was 2.5-1,000 ng/ml.Entities:
Keywords: 4-hydroxycyclophosphamide; 4-hydroxycyclophosphamide-d4; LC-MS/MS; cyclophosphamide; volumetric absorptive microsampling
Year: 2022 PMID: 36034779 PMCID: PMC9403605 DOI: 10.3389/fphar.2022.928721
Source DB: PubMed Journal: Front Pharmacol ISSN: 1663-9812 Impact factor: 5.988
LLOQ accuracy and precision.
| Analyte | LLOQ concentration (ng/mL) | Measured concentration (ng/mL) | Accuracy (%diff) | Precision (%CV) |
|---|---|---|---|---|
| Cyclophosphamide | 5 | 4.62 | −7.61 | 10.7 |
| 5.58 | 11.5 | |||
| 4.57 | −8.70 | |||
| 5.17 | 3.43 | |||
| 4.30 | −14.0 | |||
| 4-OHCP | 2.5 | 2.46 | −1.55 | 10.3 |
| 2.24 | −10.2 | |||
| 2.84 | 13.6 | |||
| 2.51 | 0.28 | |||
| 2.22 | −11.4 |
FIGURE 1Representative UPLC–MS/MS chromatograms of cyclophosphamide, 4-hydroxycyclophosphamide (4-OHCP), and 4-hydroxycyclophosphamide-d4 (4-OHCP-d4) in (A) blank VAMS; VAMS spiked with analyte at (B) LLOQ; (C) QCL; (D) QCM; and (E) QCH.
Intra- and inter-day accuracies and precision.
| Analyte | Concentration (ng/ml) | Intra-day | Inter-day | ||
|---|---|---|---|---|---|
| Mean accuracy (%diff) | Precision (%CV) | Mean accuracy (%diff) | Precision (%CV) | ||
| Cyclophosphamide | 5 | −10.1%–12.9% | 9.74 | −13.9%–12.9% | 8.85 |
| 15 | −13.4%–14.0% | 9.91 | −14.7%–14.0% | 8.58 | |
| 24.000 | 2.75%–13.9% | 4.19 | −14.9%–14.2% | 8.27 | |
| 45.000 | −8.29%–9.96% | 7.01 | −9.82%–12.3% | 6.14 | |
| 4-OHCP | 2.5 | −10.1%–9.48% | 8.34 | −14.7%–19.1% | 9.12 |
| 7.5 | −6.73%–14.5% | 7.78 | −13.5%–14.9% | 8.77 | |
| 400 | −3.05%–10.1% | 6.16 | −11.8%–12.6% | 6.94 | |
| 750 | −13.8%–10.8% | 9.24 | −13.8%–10.8% | 7.29 | |