Literature DB >> 36032198

Digital biosensor for human cerebrospinal fluid detection with single-use sensing strips.

Minghan Xian1, Chan-Wen Chiu1, Patrick H Carey1, Chaker Fares1, Liya Chen1, Rena Wu1, Fan Ren1, Cheng-Tse Tsai2, Siang-Sin Shan2, Yu-Te Liao2, Josephine F Esquivel-Upshaw3, Stephen J Pearton4.   

Abstract

Leakage of human cerebrospinal fluid (CSF) caused by trauma or other reasons presents exceptional challenges in clinical analysis and can have severe medical repercussions. Conventional test methods, including enzyme-linked immunosorbent assay and immunofixation electrophoresis testing, typically are performed at a few clinical reference laboratories, which may potentially delay proper diagnosis and treatment. At the same time, medical imaging can serve as a secondary diagnosis tool. This work presented here reports the use of a point-of-care electrochemical sensor for detection of beta-2-transferrin (B2T), a unique isomer of transferrin that is present exclusively in human CSF but is absent in other bodily fluids. Limits of detection were examined via serial dilution of human samples with known B2T concentrations down to 7 × 10-12 g B2T/ml while maintaining excellent sensitivity. Nine human samples with varying levels of B2T were compared using up to 100 times dilution to confirm the validity of sensor output across different patient samples.
© 2022 Author(s).

Entities:  

Year:  2022        PMID: 36032198      PMCID: PMC8810203          DOI: 10.1116/6.0001576

Source DB:  PubMed          Journal:  J Vac Sci Technol B Nanotechnol Microelectron        ISSN: 2166-2746


  25 in total

1.  Rapid method for beta2-transferrin in cerebrospinal fluid leakage using an automated immunofixation electrophoresis system.

Authors:  Christine Papadea; Rodney J Schlosser
Journal:  Clin Chem       Date:  2004-12-17       Impact factor: 8.327

2.  The rising incidence of spontaneous cerebrospinal fluid leaks in the United States and the association with obesity and obstructive sleep apnea.

Authors:  Rick F Nelson; Bruce J Gantz; Marlan R Hansen
Journal:  Otol Neurotol       Date:  2015-03       Impact factor: 2.311

3.  Diagnostic relevance of beta2-transferrin for the detection of cerebrospinal fluid fistulas.

Authors:  Athanasia Warnecke; Thomas Averbeck; Ulrich Wurster; Meike Harmening; Thomas Lenarz; Timo Stöver
Journal:  Arch Otolaryngol Head Neck Surg       Date:  2004-10

4.  Perilymph detection by beta 2-transferrin immunoblotting assay. Application to the diagnosis of perilymphatic fistulae.

Authors:  O Delaroche; P Bordure; E Lippert; M Sagniez
Journal:  Clin Chim Acta       Date:  1996-02-09       Impact factor: 3.786

5.  PEGylation strategies for active targeting of PLA/PLGA nanoparticles.

Authors:  Tania Betancourt; James D Byrne; Nicole Sunaryo; Spencer W Crowder; Meena Kadapakkam; Shefali Patel; Shelly Casciato; Lisa Brannon-Peppas
Journal:  J Biomed Mater Res A       Date:  2009-10       Impact factor: 4.396

6.  Comprehensive algorithm for skull base dural lesion and cerebrospinal fluid fistula diagnosis.

Authors:  Cem Meco; Gerhard Oberascher
Journal:  Laryngoscope       Date:  2004-06       Impact factor: 3.325

7.  Point-of-Care Cerebrospinal Fluid Detection.

Authors:  Ashley E Kita; Daniel W Bradbury; Zachary D Taylor; Daniel T Kamei; Maie A St John
Journal:  Otolaryngol Head Neck Surg       Date:  2018-07-24       Impact factor: 3.497

8.  Fast SARS-CoV-2 virus detection using disposable cartridge strips and a semiconductor-based biosensor platform.

Authors:  Minghan Xian; Hao Luo; Xinyi Xia; Chaker Fares; Patrick H Carey; Chan-Wen Chiu; Fan Ren; Siang-Sin Shan; Yu-Te Liao; Shu-Min Hsu; Josephine F Esquivel-Upshaw; Chin-Wei Chang; Jenshan Lin; Steven C Ghivizzani; Stephen J Pearton
Journal:  J Vac Sci Technol B Nanotechnol Microelectron       Date:  2021-05-18

9.  Capacitance-modulated transistor detects odorant binding protein chiral interactions.

Authors:  Mohammad Yusuf Mulla; Elena Tuccori; Maria Magliulo; Gianluca Lattanzi; Gerardo Palazzo; Krishna Persaud; Luisa Torsi
Journal:  Nat Commun       Date:  2015-01-16       Impact factor: 14.919

Review 10.  Surgical repair of spontaneous cerebrospinal fluid (CSF) leaks: A systematic review.

Authors:  Brian C Lobo; Maraya M Baumanis; Rick F Nelson
Journal:  Laryngoscope Investig Otolaryngol       Date:  2017-04-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.