Megavoltage portal films using computed radiographic imaging with photostimulable phosphors.

R M Wilenzick, C R Merritt, S Balter.   

Abstract

Conventional portal films taken with high-energy x rays are severely impaired by poor image quality, and many attempts have been made to overcome this problem. A new technology, computed radiographic imaging, has been investigated as a means of producing images taken with 6-and 10-MV x rays. The computed radiographic imaging (CRI) system is based on the principle of laser-stimulated luminescence induced in an image receptor plate exposed to ionizing radiation, and direct conversion of the light into digital form. Image processing using contrast enhancement and unsharp masking yields images at least as good as the best portal films obtainable with conventional commercial radiotherapy cassettes. Additionally, CRI offers advantages of reduced image size and digital storage. The system is capable of producing normal film densities over an extremely wide range of exposure.

Entities:  

Mesh:

Year:  1987        PMID: 3600529     DOI: 10.1118/1.596054

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Opportunities for Fluorochlorozirconate and Other Glass-Ceramic Detectors in Medical Imaging Devices.

Authors:  Jacqueline A Johnson; Russell L Leonard; A R Lubinsky; Stefan Schweizer
Journal:  J Biomed Technol Res       Date:  2015-06-25

2.  A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography.

Authors:  Christopher F Njeh; Blas Caroprese; Pushkar Desai
Journal:  Radiat Oncol       Date:  2012-03-27       Impact factor: 3.481

3.  Third party EPID with IGRT capability retrofitted onto an existing medical linear accelerator.

Authors:  D O Odero; D S Shimm
Journal:  Biomed Imaging Interv J       Date:  2009-07-01

4.  Verification of prostate treatment setup using computed radiography for portal imaging.

Authors:  Richard Whittington; Peter Bloch; Della Hutchinson; Bengt E Bjarngard
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

5.  Detection of electron beam energy variations using a computed radiography system.

Authors:  Yang C Cai; Yuanyuan Ge; Damian Bernard; Julius Turian; James C H Chu
Journal:  J Appl Clin Med Phys       Date:  2009-10-15       Impact factor: 2.102