Literature DB >> 36001270

Artificial intelligence computer-aided detection enhances synthesized mammograms: comparison with original digital mammograms alone and in combination with tomosynthesis images in an experimental setting.

Takayoshi Uematsu1, Kazuaki Nakashima2, Taiyo Leopoldo Harada2, Hatsuko Nasu3, Tatsuya Igarashi4.   

Abstract

BACKGROUND: It remains unclear whether original full-field digital mammograms (DMs) can be replaced with synthesized mammograms in both screening and diagnostic settings. To compare reader performance of artificial intelligence computer-aided detection synthesized mammograms (AI CAD SMs) with that of DM alone or in combination with digital breast tomosynthesis (DBT) images in an experimental setting.
METHODS: We compared the performance of multireader (n = 4) and reading multicase (n = 388), in 84 cancers, 83 biopsy-proven benign lesions, and 221 normal or benign cases with negative results after 1-year follow-up. Each reading was independently interpreted with four reading modes: DM, AI CAD SM, DM + DBT, and AI CAD SM + DBT. The accuracy of probability of malignancy (POM) and five-category ratings were evaluated using areas under the receiver operating characteristic curve (AUC) in the random-reader analysis.
RESULTS: The mean AUC values based on POM for DM, AI CAD SM, DM + DBT, and AI CAD SM + DBT were 0.871, 0.902, 0.895, and 0.909, respectively. The mean AUC of AI CAD SM was significantly higher (P = 0.002) than that of DM. For calcification lesions, the sensitivity of SM and DM did not differ significantly (P = 0.204). The mean AUC for AI CAD SM + DBT was higher than that of DM + DBT (P = 0.082). ROC curves based on the five-category ratings showed similar proximity of the overall performance levels.
CONCLUSIONS: AI CAD SM alone was superior to DM alone. Also, AI CAD SM + DBT was superior to DM + DBT but not statistically significant.
© 2022. The Author(s).

Entities:  

Keywords:  Artificial intelligence; Breast cancer; Digital breast tomosynthesis; Digital mammography; Synthesized mammography

Year:  2022        PMID: 36001270     DOI: 10.1007/s12282-022-01396-4

Source DB:  PubMed          Journal:  Breast Cancer        ISSN: 1340-6868            Impact factor:   3.307


  23 in total

1.  Additional diagnostic value of shear-wave elastography and color Doppler US for evaluation of breast non-mass lesions detected at B-mode US.

Authors:  Ji Soo Choi; Boo-Kyung Han; Eun Young Ko; Eun Sook Ko; Jung Hee Shin; Ga Ram Kim
Journal:  Eur Radiol       Date:  2016-01-19       Impact factor: 5.315

2.  Comparison of synthetic mammography, reconstructed from digital breast tomosynthesis, and digital mammography: evaluation of lesion conspicuity and BI-RADS assessment categories.

Authors:  Giovanna Mariscotti; Manuela Durando; Nehmat Houssami; Mirella Fasciano; Alberto Tagliafico; Davide Bosco; Cristina Casella; Camilla Bogetti; Laura Bergamasco; Paolo Fonio; Giovanni Gandini
Journal:  Breast Cancer Res Treat       Date:  2017-08-17       Impact factor: 4.872

3.  Evaluation of microcalcification contrast in clinical images for digital mammography and synthetic mammography.

Authors:  P Baldelli; P Cardarelli; F Flanagan; S Maguire; N Phelan; S Tomasi; A Taibi
Journal:  Eur J Radiol       Date:  2021-05-06       Impact factor: 3.528

4.  Comparative analysis between synthetic mammography reconstructed from digital breast tomosynthesis and full-field digital mammography for breast cancer detection and visibility.

Authors:  Ryusuke Murakami; Nachiko Uchiyama; Hitomi Tani; Tamiko Yoshida; Shinichiro Kumita
Journal:  Eur J Radiol Open       Date:  2020-01-28

5.  Comparison of two-dimensional synthesized mammograms versus original digital mammograms alone and in combination with tomosynthesis images.

Authors:  Margarita L Zuley; Ben Guo; Victor J Catullo; Denise M Chough; Amy E Kelly; Amy H Lu; Grace Y Rathfon; Marion Lee Spangler; Jules H Sumkin; Luisa P Wallace; Andriy I Bandos
Journal:  Radiology       Date:  2014-01-21       Impact factor: 11.105

6.  Digital breast tomosynthesis for breast cancer detection: a diagnostic test accuracy systematic review and meta-analysis.

Authors:  Mostafa Alabousi; Nanxi Zha; Jean-Paul Salameh; Lucy Samoilov; Anahita Dehmoobad Sharifabadi; Alex Pozdnyakov; Behnam Sadeghirad; Vivianne Freitas; Matthew D F McInnes; Abdullah Alabousi
Journal:  Eur Radiol       Date:  2020-01-03       Impact factor: 5.315

7.  Performance of Digital Breast Tomosynthesis, Synthetic Mammography, and Digital Mammography in Breast Cancer Screening: A Systematic Review and Meta-Analysis.

Authors:  Mostafa Alabousi; Akshay Wadera; Mohammed Kashif Al-Ghita; Rayeh Kashef Al-Ghetaa; Jean-Paul Salameh; Alex Pozdnyakov; Nanxi Zha; Lucy Samoilov; Anahita Dehmoobad Sharifabadi; Behnam Sadeghirad; Vivianne Freitas; Matthew Df McInnes; Abdullah Alabousi
Journal:  J Natl Cancer Inst       Date:  2021-06-01       Impact factor: 13.506

8.  Accuracy of Digital Breast Tomosynthesis for Detecting Breast Cancer in the Diagnostic Setting: A Systematic Review and Meta-Analysis.

Authors:  Min Jung Ko; Dong A Park; Sung Hyun Kim; Eun Sook Ko; Kyung Hwan Shin; Woosung Lim; Beom Seok Kwak; Jung Min Chang
Journal:  Korean J Radiol       Date:  2021-05-20       Impact factor: 3.500

Review 9.  Breast cancer screening using synthesized two-dimensional mammography: A systematic review and meta-analysis.

Authors:  Baoqi Zeng; Kai Yu; Le Gao; Xueyang Zeng; Qingxin Zhou
Journal:  Breast       Date:  2021-07-22       Impact factor: 4.380

10.  Digital breast tomosynthesis (DBT) plus synthesised two-dimensional mammography (s2D) in breast cancer screening is associated with higher cancer detection and lower recalls compared to digital mammography (DM) alone: results of a systematic review and meta-analysis.

Authors:  Sylvia H Heywang-Köbrunner; Alexander Jänsch; Astrid Hacker; Sina Weinand; Tobias Vogelmann
Journal:  Eur Radiol       Date:  2021-10-25       Impact factor: 7.034

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.