Literature DB >> 35994107

Predictive accuracy and reproducibility of the O-RADS US scoring system among sonologists with different training levels.

Manli Wu1, Man Zhang1, Junyan Cao1, Shuangyu Wu1, Ying Chen1, Liping Luo1, Xin Lin1, Manting Su1, Xinling Zhang2.   

Abstract

PURPOSE: To investigate the predictive performance and reproducibility of Ovarian-Adnexal Reporting and Data System (O-RADS) ultrasound (US) system in evaluating adnexal masses between sonologists with varying levels of expertise.
METHODS: This was a single-center retrospective study conducted between May 2019 and May 2020, which included 147 adnexal mases with pathological results. Four sonologists with varying experiences independently assigned an O-RADS US category to each adnexal mass twice. The intra- and inter-observer agreement was assessed using weighted kappa values. The area under the curve (AUC), sensitivity, specificity, positive and negative predictive value (PPV and NPV) were assessed for each sonologist.
RESULTS: Of the 147 adnexal mases, 115 (78.2%) lesions were benign and 32 (21.8%) lesions were malignant. Considering O-RADS > 3 as a predictor for adnexal malignancy, the predictive accuracies of the four sonologists were excellent, with AUCs ranging from 0.831 to 0.926. The predictive accuracies of O-RADS US by experienced sonologists were significantly higher compared to inexperienced sonologists (all P values < 0.005). The O-RADS US presented high sensitivity and NPV value for each sonologist. With regard to the reproducibility of O-RADS, the intra- and inter-observer agreement among experienced sonologists performed better than inexperienced sonologists.
CONCLUSION: O-RADS showed difference in the predictive accuracy and reproducibility in the evaluation of adnexal masses among sonologists with different levels of expertise. Training is required for inexperienced sonologists before the generalization of O-RADS classification system in clinical practice.
© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  Adnexal mass; O-RADS; Predictive accuracy; Reproducibility

Year:  2022        PMID: 35994107     DOI: 10.1007/s00404-022-06752-5

Source DB:  PubMed          Journal:  Arch Gynecol Obstet        ISSN: 0932-0067            Impact factor:   2.493


  3 in total

1.  The Prospective External Validation of International Ovarian Tumor Analysis (IOTA) Simple Rules in the Hands of Level I and II Examiners.

Authors:  A Knafel; T Banas; A Nocun; M Wiechec; R Jach; A Ludwin; M Kabzinska-Turek; M Pietrus; K Pitynski
Journal:  Ultraschall Med       Date:  2015-06-30       Impact factor: 6.548

2.  Comparison of O-RADS, GI-RADS, and ADNEX for Diagnosis of Adnexal Masses: An External Validation Study Conducted by Junior Sonologists.

Authors:  Hong-Wei Lai; Guo-Rong Lyu; Zhuo Kang; Li-Ya Li; Ying Zhang; Yi-Jun Huang
Journal:  J Ultrasound Med       Date:  2021-09-21       Impact factor: 2.153

3.  Synchronous tele-ultrasonography is helpful for a naive operator to perform high-quality thyroid ultrasound examinations.

Authors:  Xiao-Long Li; Yi-Kang Sun; Qiao Wang; Zi-Tong Chen; Zhe-Bin Qian; Le-Hang Guo; Hui-Xiong Xu
Journal:  Ultrasonography       Date:  2022-03-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.