Dalia L Swinya1, Daniel Martín-Yerga1, Marc Walker2, Patrick R Unwin1. 1. Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom. 2. Department of Physics, University of Warwick, Coventry CV4 7AL, United Kingdom.
Abstract
Dopamine (DA) adsorption and electron-transfer kinetics are strongly sensitive to the structure and composition of carbon electrodes. Activation of carbon surfaces is a popular method to improve DA detection, but the role of carbon structural features on DA behavior remains uncertain. Herein, we use scanning electrochemical cell microscopy (SECCM) for local anodization of glassy carbon (GC) electrodes in acid media followed by electrochemical imaging of DA adsorption and electrochemistry covering both unmodified and anodized GC regions of the same electrode. Electrochemical measurements of adsorbed DA involve the delivery of DA from the SECCM meniscus (30 μM) for 1 s periods followed by voltammetric analysis at a reasonable sweep rate (47 V s-1). This general approach reduces effects from interelectrode variability and allows for considerable numbers of measurements and statistical analysis of electrochemical data sets. Localized electrode activity is correlated to surface structure and chemistry by a range of characterization techniques. Anodization enhances DA electron-transfer kinetics and provides more sites for adsorption (higher specific surface area). A consequence is that adsorption takes longer to approach completion on the anodized surface. In fact, normalizing DA surface coverage by the electrochemical surface area (ECSA) reveals that adsorption is less extensive on anodized surfaces compared to as-prepared GC on the same time scale. Thus, ECSA, which has often been overlooked when calculating DA surface coverage on carbon electrodes, even where different activation methods would be expected to result in different surface roughness and nanostructure, is an important consideration. Lower graphitic and higher oxygen content on anodized GC also suggest that oxygen-containing functional groups do not necessarily enhance DA adsorption and may have the opposite effect. This work further demonstrates SECCM as a powerful technique for revealing surface structure-function relationships and correlations at heterogeneous electrodes.
Dopamine (DA) adsorption and electron-transfer kinetics are strongly sensitive to the structure and composition of carbon electrodes. Activation of carbon surfaces is a popular method to improve DA detection, but the role of carbon structural features on DA behavior remains uncertain. Herein, we use scanning electrochemical cell microscopy (SECCM) for local anodization of glassy carbon (GC) electrodes in acid media followed by electrochemical imaging of DA adsorption and electrochemistry covering both unmodified and anodized GC regions of the same electrode. Electrochemical measurements of adsorbed DA involve the delivery of DA from the SECCM meniscus (30 μM) for 1 s periods followed by voltammetric analysis at a reasonable sweep rate (47 V s-1). This general approach reduces effects from interelectrode variability and allows for considerable numbers of measurements and statistical analysis of electrochemical data sets. Localized electrode activity is correlated to surface structure and chemistry by a range of characterization techniques. Anodization enhances DA electron-transfer kinetics and provides more sites for adsorption (higher specific surface area). A consequence is that adsorption takes longer to approach completion on the anodized surface. In fact, normalizing DA surface coverage by the electrochemical surface area (ECSA) reveals that adsorption is less extensive on anodized surfaces compared to as-prepared GC on the same time scale. Thus, ECSA, which has often been overlooked when calculating DA surface coverage on carbon electrodes, even where different activation methods would be expected to result in different surface roughness and nanostructure, is an important consideration. Lower graphitic and higher oxygen content on anodized GC also suggest that oxygen-containing functional groups do not necessarily enhance DA adsorption and may have the opposite effect. This work further demonstrates SECCM as a powerful technique for revealing surface structure-function relationships and correlations at heterogeneous electrodes.
Monitoring dopamine (DA) concentration
fluctuations and transmission
is important in the study of several neurological and cognitive processes,[1−3] with electrochemical detection enabling the accurate monitoring
of DA levels in different biological fluids and tissues.[4−6] DA electrochemistry involves proton-coupled electron transfer, with
a two-electron two-proton oxidation, through the catechol group[7] to form dopaminequinone (DAQ) (Figure S1).[8,9] DAQ can then suffer a subsequent
cascade of chemical/electrochemical side reactions, ultimately leading
to the formation of melanin-like polymeric compounds[10] that can result in the fouling of electrode surfaces.[11,12]Carbon-based electrodes are very attractive for DA detection.[13] For instance, carbon-fiber microelectrodes (CFMEs)
are standard tools to carry out in vivo measurements of neurotransmitters[6] with high spatiotemporal resolution through fast-scan
cyclic voltammetry.[14] Other carbon-based
materials such as glassy carbon (GC),[15] carbon nanotubes,[16,17] screen-printed graphite,[18] boron doped diamond,[19] and graphene[20] have also been reported
as electrodes for DA analytical determination. DA adsorption, electrochemical
kinetics, and fouling are strongly affected by the nature of the carbon
electrode surface.[11,12] In this regard, activation procedures,
which are known to change surface properties and composition, are
typically used to improve DA detection.[21,22] Such activation
can affect the electron-transfer kinetics and adsorption,[23−25] thereby decreasing overpotentials and improving sensitivity and
resolution. This ability to tailor the carbon surface structure has
been widely exploited to study DA response on GC electrodes activated
by different methods such as heat,[26] laser,[27,28] and plasma[29] treatments. Surface polishing
can also introduce compositional changes by increasing the content
of surface oxide groups.[30] In turn, this
was believed to promote DA adsorption through electrostatic interaction
and/or ion-exchange between the negatively charged surface oxide layer
and the protonated amine group in DA.[31] However, quantum chemistry calculations indicate that adsorption
occurs through a noncovalent interaction between the π-system
of the aryl ring and graphitized regions of the surface.[32]Electrochemical anodization has been widely
employed to activate
carbon surfaces[15,31−35] and remove surface impurities.[34] This process generally leads to changes in the surface
micro/nanostructure, as surface roughening is typically observed,[15] due to etching of the carbon material by oxidation
to CO2,[35,36] resulting in increased electrode/electrolyte
capacitance[37,38] and electrochemically active
surface area.[36] Oxygen functionalities
are created on the carbon surface by partial oxidation.[39] All of these factors can influence DA adsorption
and reactivity, but their individual effects are difficult to resolve,
and sometimes, contradictory phenomena have been reported. For instance,
GC anodization has been reported to promote catechol adsorption,[40] although an absence of DA adsorption with a
significant increase of electron-transfer kinetics has also been recently
described.[32] Specific anodization conditions,
such as the applied potential, time, and electrolyte media, can also
affect the GC surface structure and composition.[41] New approaches are thus required to reveal structure–activity
relationships for carbon electrodes that provide original insights
into DA adsorption and electrochemistry, and enable the rational design
of improved electrode surfaces for high-sensitivity detection of neurotransmitters.Scanning electrochemical probe microscopy techniques have been
used successfully to study the local activity of carbon electrodes
for the electrochemical oxidation of DA[42−45] and other neurotransmitters.[46,47] Scanning electrochemical cell microscopy (SECCM) revealed that the
basal plane of graphite showed high DA electro-oxidation activity,[42] and measurements on HOPG with a wide range of
step edge density showed that the voltammetric response (and blocking
in repetitive voltammetric cycles) could be explained entirely by
the electrochemistry of the basal plane alone.[11] That graphite particles with a high degree of crystallinity
promote fast electro-oxidation of adsorbed DA was further confirmed
with coupled SECCM–Raman microscopy imaging of screen-printed
carbon electrodes.[43]In this work,
SECCM is used to carry out local anodization of GC
electrodes with a large tip (30 μm diameter) and then to produce
spatially resolved electrochemical maps and movies of DA adsorption
and electrochemical reactivity with a small tip (800 nm diameter),
with the scan area covering both unmodified and locally anodized regions
of the GC surface. This approach provides direct visualization of
any changes in DA behavior, in the same experiment, that are readily correlated to the carbon surface structure by
a range of surface characterization techniques (atomic force microscopy
(AFM), Raman, energy-dispersive X-ray spectroscopy (EDS), and X-ray
photoelectron spectroscopy (XPS)). SECCM is applied under conditions
where the DA electro-oxidation signature is due to adsorbed DA: fast
scan rates (47 V s–1) and low concentrations (micromolar
level), where fouling should be relatively insignificant. Anodization
of GC clearly enhances DA electron-transfer kinetics, although an
apparent increase in DA adsorption is attributed to the effect of
the increased surface area due to surface roughening. This change
in surface nanostructure leads to DA adsorption taking longer to approach
completion on the rougher surfaces. The correlative multi-microscopy
approach outlined herein is generally applicable for the determination
of structure–adsorption–activity relationships for heterogeneous
electrode surfaces.
Methods
Materials and Chemicals
Dopamine hydrochloride (≥98%),
perchloric acid (HClO4, 70% w/w), and phosphate-buffered
saline (PBS) (0.05 M with 0.138 M NaCl, pH 7.4) were purchased from
Sigma-Aldrich. Sulfuric acid (≥98%) was purchased from Fisher
Scientific. Stock solutions of DA were prepared in 0.1 M HClO4 and stored in a fridge at 4 °C. DA solutions in PBS
were prepared daily from the stock solution, and the pH was measured
using a pH meter (UltraBASIC pH meter, Denver Instruments). Ultrapure
water from a Millipore Milli-Q system (resistivity: 18.2 MΩ
cm at 25 °C) was used throughout. High-quality glassy carbon
(GC) (25 × 25 × 3 mm) was purchased from Alfa Aesar. The
GC was polished before each experiment using a polishing pad with
alumina slurry (particle size: 0.05 μm, Buehler). After polishing,
the GC was sonicated in ultrapure water for 20 min.
Local Electrochemical Measurements
All SECCM experiments
were performed using a home-built scanning electrochemical probe microscopy
workstation.[48−50] Local anodization of the GC electrode was carried
out with SECCM in the static mode at one location of the GC surface
as illustrated in Figure a. A pipet probe with a diameter of ca. 30 μm (Figure b) was pulled from
a single channel borosilicate capillary (BF100-50-10, Harvard Apparatus)
using a PC-10 Narishige puller. An AgCl-coated Ag wire was inserted
into the pipet to act as a quasi-reference counter electrode (QRCE).
The pipet, filled with 5 mM H2SO4, was approached
to the GC surface at 3 μm s–1 using a z piezoelectric stage (P-753.3CD, Physik Instrumente), and
landing was detected by a change in
the surface current (isurf) with a threshold
of 11 pA (at +0.1 V vs Ag/AgCl QRCE), which indicated the formation
of a liquid meniscus between the pipet and the GC surface (without
contact from the pipet). After landing, GC anodization was initiated
by applying a constant potential of +1.5 V vs Ag/AgCl QRCE for either
60 or 300 s (Figure c). The anodization potential was selected based on previously reported
values.[32,34,51,52]
Figure 1
(a) Schematic of the SECCM device operated in the static
mode to
carry out the local anodization of the GC electrode. A single-channel
pipet filled with 5 mM H2SO4 was approached
to the GC surface, and a chronoamperometric experiment was applied
through a constant potential (−Eapp) of +1.5 V vs Ag/AgCl QRCE for 60 or 300 s, measuring the surface
current (isurf) flowing at the GC electrode.
(b) Optical image of the end of a pipet with ca. 30 μm diameter.
(c) Plots showing the variation of the pipet z position,
the applied potential, and the measured current as a function of time
during the anodization. (d) Schematic of the SECCM hopping protocol
to study DA adsorption and electrochemistry on the locally anodized
GC surface. (e) A pipet probe with ca. 800 nm diameter was translated
to a series of predefined locations on the GC electrode to cover both
pristine (polished) and anodized regions within the same experiment.
(f) Plots showing the SECCM protocol in one location including the
variation of the pipet z position to achieve meniscus–surface
contact, the voltammetric program (equilibration for 1 s at −0.4
V followed by a five-times repeated sequence of 1 s at −0.4
V and then a voltammetric sweep analysis between −0.4 and +
0.8 V at 47 V s–1, taking ca. 50 ms; DA adsorption
occurs during the periods at −0.4 V), and the typical current
response as a function of time obtained.
(a) Schematic of the SECCM device operated in the static
mode to
carry out the local anodization of the GC electrode. A single-channel
pipet filled with 5 mM H2SO4 was approached
to the GC surface, and a chronoamperometric experiment was applied
through a constant potential (−Eapp) of +1.5 V vs Ag/AgCl QRCE for 60 or 300 s, measuring the surface
current (isurf) flowing at the GC electrode.
(b) Optical image of the end of a pipet with ca. 30 μm diameter.
(c) Plots showing the variation of the pipet z position,
the applied potential, and the measured current as a function of time
during the anodization. (d) Schematic of the SECCM hopping protocol
to study DA adsorption and electrochemistry on the locally anodized
GC surface. (e) A pipet probe with ca. 800 nm diameter was translated
to a series of predefined locations on the GC electrode to cover both
pristine (polished) and anodized regions within the same experiment.
(f) Plots showing the SECCM protocol in one location including the
variation of the pipet z position to achieve meniscus–surface
contact, the voltammetric program (equilibration for 1 s at −0.4
V followed by a five-times repeated sequence of 1 s at −0.4
V and then a voltammetric sweep analysis between −0.4 and +
0.8 V at 47 V s–1, taking ca. 50 ms; DA adsorption
occurs during the periods at −0.4 V), and the typical current
response as a function of time obtained.Spatially resolved voltammetric SECCM measurements
were performed
using the hopping mode (Figure d). A pipet probe of ca. 800 nm diameter (Figure e) was pulled from a borosilicate
capillary (BF 120-69-10, Harvard Apparatus) using a CO2 laser puller (P-2000, Sutter Instruments). The pipet was filled
with 30 μM DA in PBS (pH 7.4), and the SECCM procedure involved
a series of predefined steps (Figure f) at different locations (pixels in maps) of the GC
sample. Briefly, the pipet probe was approached to the GC surface
at 3 μm s–1 until reaching an isurf threshold of 4 pA (at −0.4 V vs AgAgCl QRCE),
which indicated contact of the liquid meniscus of the pipet with the
GC surface. The resulting electrochemical cell was maintained at this
potential for 1 s to allow for DA adsorption followed by a cyclic
voltammetry (CV) measurement at a scan rate of 47 V s–1 between −0.4 V (start and end) and +0.8 V (reverse potential)
vs Ag/AgCl QRCE. This voltammetric process was repeated a further
four times (five cycles in total), with a 1 s pause between each (at
−0.4 V), so as to follow the evolution of DA adsorption. The
pipet probe was then retracted and moved to a new location (pixel)
at 5 μm s–1 to repeat the same procedure at
a predefined grid of pixels separated by 5 μm. The sample was
translated in the xy directions using a XY piezoelectric stage (P-621.2CD). Data acquisition was achieved using
an FPGA card (PCIe-7852R, National Instruments) with a LabVIEW 2019
interface running the Warwick Electrochemical Scanning Probe Microscopy
(WEC-SPM) software. A data acquisition rate of 130 μs was used,
as isurf was measured every 2 μs
and averaged 64 times, with one extra iteration used to transfer data
to the computer. The whole SECCM setup was placed on a passive mechanical
vibration isolation platform within a Faraday cage equipped with heat
sinks and acoustic foam to minimize mechanical vibration, electrical
noise, and thermal drift. All experiments were performed at room temperature.
Data processing and analysis were done with a Python code using SciPy
libraries.[53] Statistical analysis was conducted
with Minitab 19.1 (Minitab Ltd.), with p values significant
at the 95% confidence level (p < 0.05).
Surface Characterization
An Olympus BH2 optical microscope
under top-side illumination (reflection mode) equipped with a camera
(PL-B782U, 4× lens, Pixelink) was used to measure the diameter
of the ca. 30 μm pipet probes.AFM was carried out using
an Innova microscope (Bruker) in tapping mode with Antimony (n) doped
Si probes (RFESP-75, Bruker). Scans were recorded with 512 points
per line at 0.1 Hz over 10 × 10 μm2 of the GC
electrode area. AFM images were analyzed with the Gwyddion software
(v2.55, Czech Metrology Institute).Scanning electron microscopy
(SEM) was employed to measure the
diameter of the ca. 800 nm pipet probes and to record images of the
droplet footprints left by the liquid meniscus during the SECCM experiments.
SEM images were obtained with a field emission scanning electron microscope
(FE-SEM, ZEISS Gemini, Germany) at an acceleration voltage of 5 kV
using the In Lens detector. Elemental quantification was carried out
by EDS using the integrated detector of the SEM instrument.Raman imaging was implemented using a Renishaw InVia Microscope
with a 532 nm excitation laser at 100% nominal power (35 mW), spread
out over 1000 spots, and 1800 mm–1 gratings. Acquisition
time was 1 s by spectrum.XPS data were collected at the Photoemission
RTP (University of
Warwick). GC samples were attached to an electrically conductive carbon
tape and mounted onto a sample bar before being loaded into a Kratos
Axis Ultra DLD spectrometer that possesses a base pressure below 10–10 mbar. XPS measurements were performed in the main
analysis chamber, with the sample being illuminated using a monochromatic
Al Kα X-ray source (hν = 1486.7 eV). Measurements were
conducted at room temperature and at a take-off angle of 90°
with respect to the surface parallel. Core-level spectra were recorded
using a pass energy of 20 eV (resolution approx. 0.4 eV) from an analysis
area of 300 × 700 μm. To exclusively cover an anodized
area during XPS measurement, a region of the GC sample (diameter =
ca. 5 mm) was anodized under the same electrochemical conditions as
for SECCM but using a larger droplet-based cell. The work function
and binding energy scale of the spectrometer were calibrated using
the Fermi edge and 3d5/2 peak recorded from a polycrystalline
Ag sample prior to the experiments. Data were analyzed in the CasaXPS
package using Shirley backgrounds and mixed Gaussian–Lorentzian
(Voigt) line shapes. For compositional analysis, the analyzer transmission
function was determined using clean metallic foils to determine the
detection efficiency across the full binding energy range.
Results and Discussion
Characterization of Locally Anodized Glassy Carbon
Local surface anodization was performed with SECCM in the static
mode using a ca. 30 μm diameter pipet filled with 5 mM H2SO4 by applying a potential of +1.5 V (vs Ag/AgCl
QRCE) for 60 s. A typical current–time profile during anodization
is shown in Figure S2. A sharp surge in
current was recorded at short times from capacitive and Faradaic contributions,
and the current then decreased over time until reaching a minimum
at about 10 s (ca. 8.4 nA, ∼206 μA cm–2 considering the area of the anodized surface obtained by SEM, a
spot ca. 72 μm in diameter), with a further steady increase
reaching ca. 10.9 nA at 60 s. The total charge transferred during
the anodization process was ca. 0.61 μC.The locally anodized
GC surface was characterized by Raman microscopy, EDS, XPS, and AFM. Figure S3 shows representative Raman spectra
recorded for pristine and anodized regions of the GC. These spectra
display the D and G bands typical of carbon-based materials, characteristic
of C(sp3) and C(sp2),[54,55] at 1349 and 1594 cm–1, respectively. Although
the spectra recorded in pristine and anodized areas were qualitatively
similar, quantitative differences are observed by mapping the intensity
ratio of the D and G bands (ID/IG) (Figure a), which informs on the degree of disorder in carbon
materials.[56] The D/G band ratio was slightly
smaller in the anodized region, suggesting a relative decrease of
C(sp3) compared to C(sp2) after anodization
and consistent with previous studies using carbon-fiber electrodes.[57] It is not clear what causes this decrease in
the ID/IG ratio,
with some hypotheses including the decarboxylation of the carbon surface[57] or the effect from molecular vibrations’
contribution in the Raman spectra (by functional groups) rather than
phonon vibrations by a higher degree of graphitization.[41] Increased carbon amorphization could also have
the same effect in the ID/IG ratio.[54]
Figure 2
(a) Raman map obtained
by plotting the ratio of the D and G bands
(ID/IG) typical
of carbon materials, where the locally anodized area can be readily
observed by a slightly smaller ID/IG ratio (illustrated by a darker area in the
map). (b) Relative composition (%) of C-based functional groups obtained
by analyzing the C 1s XPS spectra on pristine and anodized GC samples.
See Figure S6 for high-resolution XPS spectra.
(c) AFM image of surface topography covering pristine and anodized
regions of the GC electrode. (d) Line scan profile of surface topography
extracted from the dashed black arrow indicated in panel c covering
anodized and pristine regions. Local anodization was carried out for
60 s in 5 mM H2SO4 using a ca. 30 μm pipet
probe.
(a) Raman map obtained
by plotting the ratio of the D and G bands
(ID/IG) typical
of carbon materials, where the locally anodized area can be readily
observed by a slightly smaller ID/IG ratio (illustrated by a darker area in the
map). (b) Relative composition (%) of C-based functional groups obtained
by analyzing the C 1s XPS spectra on pristine and anodized GC samples.
See Figure S6 for high-resolution XPS spectra.
(c) AFM image of surface topography covering pristine and anodized
regions of the GC electrode. (d) Line scan profile of surface topography
extracted from the dashed black arrow indicated in panel c covering
anodized and pristine regions. Local anodization was carried out for
60 s in 5 mM H2SO4 using a ca. 30 μm pipet
probe.Changes in chemical composition on the GC surface
after anodization
were first evaluated by EDS, as a difference in contrast between anodized
and pristine regions was observed by SEM (Figure S4a). A slight increase in oxygen content (from 0.05 ±
0.07 to 0.15 ± 0.05 O at. %) was recorded after anodization (Figure S4b). Note that bulk carbon contributes
significantly to these EDX signals, which are also close to the limit
of detection. A more accurate quantification of surface chemistry
is provided by XPS. Significant differences in chemical composition
were obtained by XPS, which provides a higher depth resolution than
EDS and highlights the surface changes. XPS survey spectra are shown
in Figure S5, whereas high-resolution C
1s and O 1s deconvoluted spectra are shown in Figures S6 and S7, respectively. Table S1 summarizes the assignment of functional groups by binding
energy. The oxygen content (in atomic %) increased from 13.8 to 30.2%
after anodization, whereas the carbon content decreased from 83.8
to 66.8%. Figure b
shows the relative content of carbon functional groups between pristine
and anodized GC surfaces. The most significant changes from the C
1s spectra (Figure S6) were the strong
decrease in C(sp2) (from 72 to 14.7%), increase in C(sp3) (from 8.3 to 36.9%), and generation of alcohol (C–OH)
groups (28.7%) that were not present on the pristine GC. These trends
are similar to those found on previous GC anodization studies.[32,36,58] Other groups such as carboxylates
(O=C–O) and carbonyls (C=O) also increased by
the anodization, from 4.1 to 9.3% and 3.2 to 5.9%, respectively, whereas
the content of ethers/epoxides (C–O–C) decreased from
8.1 to 3.6% and π–π* shake-up, a feature of a delocalized
(aromatic) graphitic network,[59] also decreased
from 4.3 to 0.9%. This decrease in graphitic content after anodization
is relevant because, as highlighted earlier, DA adsorption has been
recently proposed to occur between the π-system of the aryl
ring of the catechol and the graphitized regions of the carbon surface,
as supported by computational studies[32] and also observed in previous experiments where the adsorption of
electroactive DA occurred efficiently on low-defective graphitic surfaces.[42,43] Two main regions can be observed in the O 1s spectra (Figure S7): C–O from alcohols, ethers/epoxides,
and esters and C=O from ketones, carboxylic acids, and esters.
The overall change demonstrates a strong increase in C–O from
27 to 57.4% and decrease in C=O from 59.6 to 37.2% on the anodized
GC surface. This observation is likely to be dominated by the extensive
generation of C–OH groups on the surface, as detected in the
C 1s spectra.Anodization led to a significant increase of surface
roughness
as observed by AFM (Figure c) and in the roughness profile across the pristine and anodized
regions (Figure d),
with a noticeable development of nanoscale crevices (Figure S8). Surface roughening was estimated quantitatively
by calculating the root-mean-square roughness. The roughness changed
by a factor of 1.9 from 0.93 ± 0.05 nm (pristine) to 1.78 ±
0.09 nm (anodized). Increased roughness after anodization will affect
the double-layer capacitance, which can be related to electrochemical
surface area (ECSA) assuming that the specific capacitance is relatively
insensitive to surface functionalization.
Dopamine Adsorption and Oxidation on Locally Anodized Glassy
Carbon
SECCM was used to study DA oxidation on pristine and
anodized areas (60 s anodization) using the procedure illustrated
in Figure d. To ensure
conditions where the electrochemical response for DA would be dominated
by adsorbed DA, a low DA concentration (30 μM) and a fast voltammetric
scan rate (47 V s–1) were used while allowing time
(a period of 2 s and four periods of 1 s) for DA to adsorb on the
GC surface before each of five voltammetric measurements were recorded
in sequence. A surface-controlled response was confirmed by a scan-rate
study (Figure S9). Noting that mass transport
in SECCM is relatively fast and quickly attains a steady state[60] and that, as a rule of thumb, the steady-state
mass transport rate is ca. 10% of the equivalent disk microelectrode,[61], where D ∼6 ×
10–6 cm2 s–1 is the
DA diffusion coefficient,[45]c is the bulk DA concentration (30 μM), and a is the pipet radius (0.4 μm), there is sufficient flux from
the pipet for >1.4 × 10–10 mol cm–2 (area of meniscus footprint) to adsorb in each adsorption period
(2.8 × 10–10 mol cm–2 in
the first period), in excess of the measured values of adsorbed DA
on both pristine and anodized surfaces (vide infra).The pipet probe was translated across both pristine and
anodized regions in the same SECCM experiment as illustrated in Figure d. Representative
SECCM CVs for DA oxidation (forward sweep) and reduction of the product
DAQ (reverse sweep) on pristine and anodized regions of GC are shown
in Figure . Quantitatively
similar peak currents were obtained for the five cycles on the pristine
GC surface (Figure a). This response indicates that DA adsorption to completion takes
place quickly on pristine areas before the first cycle, as the oxidation
current does not increase upon cycling. Anodic peak currents ca. 65
pA were measured on pristine regions, which are significantly higher
than the several pA estimated for a transient diffusion-controlled
process (assuming planar diffusion, given that the diffusion layer
thickness will be on the micrometer scale at this voltammetric scan
rate) or the ca. 1 pA steady-state SECCM current.[62,63] This confirms that the oxidation and reduction signatures are mainly
due to adsorbed DA/DAQ. A different behavior was found for the SECCM
CVs obtained on anodized GC (Figure b). The measurable increase in DA oxidation peak currents
with cycling indicates that DA coverage grows on anodized areas during
the experiment. The longer time scale for DA adsorption in anodized
GC areas might be a consequence of the larger specific surface area
and less accessible nanoscale surface features, as observed on AFM
images (vide supra), especially relevant at low DA
concentrations as used herein. DA adsorption has also been reported
to increase for several minutes following the fracture of GC surfaces.[31] The nature of SECCM, where measurements are
carried out quickly after contact with a fresh surface, facilitates
the visualization of such time-dependent phenomena. Figure c,d shows comparatively the
average CVs for all the SECCM measurements on pristine and anodized
areas (first and fifth cycles). These plots provide a clear view of
the different electrochemical response for DA adsorption and electro-oxidation
observed on the distinct GC regions. The significant increase in capacitive
current on anodized areas is consistent with the roughening of the
GC surface structure as detected by AFM and as previously reported
in GC anodization studies.[41,64] Further analysis is
required (vide infra) to unequivocally elucidate
the relationship between the surface structure and DA adsorption,
taking into account the effect of the increased surface area.
Figure 3
Five consecutive
CVs recorded in one location by SECCM where GC
was (a) pristine and (b) modified by anodization for 60 s. Average
CVs from all the locations of the SECCM measurements where the GC
was pristine (blue trace) or anodized for 60 s (red trace) for the
(c) first and (d) fifth voltammetric cycles. Gray areas illustrate
the standard deviation. A total of 91 and 19 independent measurements
were recorded in pristine and anodized areas, respectively. DA (30
μM) in PBS was used in all cases, with 47 V s–1 as the scan rate and using a pipet probe of ca. 800 nm diameter.
Five consecutive
CVs recorded in one location by SECCM where GC
was (a) pristine and (b) modified by anodization for 60 s. Average
CVs from all the locations of the SECCM measurements where the GC
was pristine (blue trace) or anodized for 60 s (red trace) for the
(c) first and (d) fifth voltammetric cycles. Gray areas illustrate
the standard deviation. A total of 91 and 19 independent measurements
were recorded in pristine and anodized areas, respectively. DA (30
μM) in PBS was used in all cases, with 47 V s–1 as the scan rate and using a pipet probe of ca. 800 nm diameter.Spatially resolved electrochemical (i–E) movies can be constructed from the data
to represent
visually the effect of the locally anodized GC surface on DA reactivity. Movie S1 represents the i–E response of the first voltammetric cycle where different
local electrochemistry on pristine and anodized areas is obtained,
which can be correlated to their corresponding location in the SEM
images (Figure a).
The voltammetric baseline was corrected to remove the effect of the
capacitive current, highlighting only the information contained in
the DA oxidation peak. Figure b shows a frame of the SECCM movie representing the current
at ca. +0.31 V (near the onset of dopamine oxidation), where it can
be seen that larger currents were obtained on anodized areas. However,
there was not a clear difference in the magnitude of the DA oxidation
peak currents between pristine and anodized regions for the first
voltammetric cycle. This fact is highlighted through a spatially resolved
map of the electroactive DA surface concentration (Γads) shown in Figure c, with Γads calculated from Q = nFAΓads after integrating the charge under
the DA oxidation peak (Q), with F the Faraday constant, n the number of electrons
(2 e–), and A the electrode area
(defined by the geometric size of the SECCM droplet
footprints; Figure a). There appears to be little visual difference in Γads between pristine and anodized areas, with much of the anodized data
contained within the population distribution of the pristine area
(see the Γads histogram in Figure a). However, a closer inspection revealed
that Γads was statistically higher on anodized GC
(unpaired t test, p = 0.00001):
average values were 71 ± 15 and 91 ± 25 pmol cm–2 for the pristine and anodized surfaces, which indicate that the
adsorption kinetics is fast and there is a strong transport-controlled
component (based on the estimated SECCM flux, vide supra), as established for other carbon surfaces.[23] The fractional surface coverage corresponds to 28 and 36% of the
geometric GC surface, respectively. These values are calculated considering
ca. 255 pmol cm–2 as the theoretical limit for the
adsorption of a monolayer of DA in a flat configuration (molecular
area: 6.5 × 10–15 cm2).[65,66] Larger monolayer coverage values result from DA adsorption in a
vertical orientation,[66] but this occurs
at higher adsorbate concentrations for catechol-like molecules.[67] Previous values reported for DA surface concentrations
are of the same order, between 10 and 400 pmol cm–2, with the largest values observed for mechanically or electrochemically
pretreated GC surfaces,[31] but are recorded
under different conditions from our experiments. It is worth noting
that the active surface area is comparatively larger in anodized regions,
as inferred by the AFM roughness measurements and capacitive current
analysis, and so the fractional DA surface coverage (in terms of specific
surface area or ECSA) is significantly smaller in the anodized areas
(vide infra).
Figure 4
(a) SEM image of the SECCM scan area covering
pristine (darker)
and anodized for 60 s (brighter) regions of the GC electrode. (b)
Spatially resolved map of i obtained at +0.3092 V
vs Ag/AgCl QRCE (first cycle) showing DA oxidation activity across
the GC surface. Baseline was corrected to remove the effect of the
different capacitive currents. (c, d) Spatially resolved maps of DA
surface concentration (Γads) for the first and fifth
voltammetric cycle, respectively. (e, f) Spatially resolved maps of
the peak potential difference between DA oxidation and DAQ reduction
peaks (ΔEp) for the first and fifth
voltammetric cycle, respectively. SECCM maps contained 110 pixels
(55 × 50 μm2 with 5 μm as the hopping
distance).
Figure 5
Histograms of DA surface concentration (Γads)
calculated for the (a) first and (b) fifth voltammetric cycles. Histograms
of ΔEp for the (c) first and (d)
fifth voltammetric cycles. Data were obtained from anodized (red bars)
and pristine (blue bars) regions of the SECCM scan illustrated in Figure .
(a) SEM image of the SECCM scan area covering
pristine (darker)
and anodized for 60 s (brighter) regions of the GC electrode. (b)
Spatially resolved map of i obtained at +0.3092 V
vs Ag/AgCl QRCE (first cycle) showing DA oxidation activity across
the GC surface. Baseline was corrected to remove the effect of the
different capacitive currents. (c, d) Spatially resolved maps of DA
surface concentration (Γads) for the first and fifth
voltammetric cycle, respectively. (e, f) Spatially resolved maps of
the peak potential difference between DA oxidation and DAQ reduction
peaks (ΔEp) for the first and fifth
voltammetric cycle, respectively. SECCM maps contained 110 pixels
(55 × 50 μm2 with 5 μm as the hopping
distance).Histograms of DA surface concentration (Γads)
calculated for the (a) first and (b) fifth voltammetric cycles. Histograms
of ΔEp for the (c) first and (d)
fifth voltammetric cycles. Data were obtained from anodized (red bars)
and pristine (blue bars) regions of the SECCM scan illustrated in Figure .Both the electrochemical movie (Movie S2) and the Γads map for the fifth
voltammetric cycle
(Figure d) show that
DA adsorption increased in the anodized areas throughout the meniscus
contact time compared to little change in the pristine areas. Indeed,
a significant change in the population analysis is detected (Figure b), with average
values being 65 ± 14 and 180 ± 20 pmol cm–2 for pristine and anodized areas (i.e., a coverage of 26 and 71%
of the geometric GC surface), respectively. Thus, DA takes a longer
time to adsorb on all available sites on the anodized surface (noting
that there is sufficient flux for adsorption not to be limited solely
by mass transport from the pipet in this case, vide supra).
Effect of Anodization on Electron-Transfer Kinetics
To further evaluate the effect of GC anodization on DA electron-transfer
kinetics, SECCM maps representing the peak potential difference (ΔEp) for DA oxidation and DAQ reduction in the
first and fifth voltammetric cycles are shown in Figure e,f. A notable difference in
ΔEp values was obtained with DA/DAQ
reactions being significantly faster on anodized areas, as also illustrated
by analyzing the ΔEp histograms
(Figure c,d). Average
ΔEp values for the first voltammetric
cycle were 0.63 ± 0.05 V (pristine), cf. 0.49
± 0.05 V (anodized) GC. This enhancement in electron-transfer
kinetics (smaller ΔEp)[68] is consistent with previous studies using anodized
GC.[31,32] For the fifth voltammetric cycle, average
values of ΔEp were 0.61 ± 0.05
(pristine), cf. 0.43 ± 0.03 V (anodized), indicating
a slight increase in electron transfer kinetics for anodized GC upon
cycling. The change in average ΔEp with cycling was further analyzed in terms of absolute values (Figure a) and normalized
by the value at the first cycle (Figure b). While the effect of cycling was negligible
in the pristine areas (where the adsorbed quantity of DA was also
constant), in anodized areas, the kinetics was statistically enhanced
(unpaired t test, p = 0.0003) and
is correlated with increased DA coverage, consistent with a self-catalytic
effect.[69]
Figure 6
(a) Absolute variation of ΔEp with cycle number in pristine (blue trace)
and anodized (red trace)
locations of the GC surface. (b) Variation of ΔEp with cycle number normalized by the value for the first
cycle. Higher values in panel b indicate enhanced kinetics related
to those recorded in the first cycle. Error bars indicate the standard
deviation from all the SECCM pixels for specific locations (pristine
or anodized).
(a) Absolute variation of ΔEp with cycle number in pristine (blue trace)
and anodized (red trace)
locations of the GC surface. (b) Variation of ΔEp with cycle number normalized by the value for the first
cycle. Higher values in panel b indicate enhanced kinetics related
to those recorded in the first cycle. Error bars indicate the standard
deviation from all the SECCM pixels for specific locations (pristine
or anodized).
Effect of the Electrochemical Surface Area on the Apparent Dopamine
Adsorption
Γads values are calculated using
the geometric electrode area, but the increased surface area (observed
by AFM) or actual ECSA needs to be considered. The capacitive charge
(Qc) is higher on anodized areas as shown
in the SECCM map of Qc in Figure S10 (where the integrated charge was between
−0.375 and −0.275 V to avoid the DA oxidation process; Figure S11). Table S2 summarizes the average values of Qc for
anodized and pristine GC and the corresponding anodized/pristine ratio
after subtracting the contribution from stray capacitance. The anodized/pristine Qc ratio was 3.3 for the first voltammetric cycle,
which is larger than the surface roughness ratio calculated by AFM
(ca. 1.9). The value obtained from AFM will always underestimate the
true area due to the finite tip size that restricts access to small
and deep features of the rough anodized surface. Yet, the Qc ratio is only ca. 50% larger than the AFM
surface roughness measurement, suggesting that functional groups on
the carbon surface after anodization only make a minor contribution
to the specific capacitance in this potential range. We thus propose
that the Qc ratio is a reasonable estimate
of the ECSA enhancement upon anodization. Certainly, any functionalization
of the GC upon anodization does not result in any change in wetting,
as the SECCM droplet footprints are very consistent throughout both
areas of the GC surface (Figure S12).We evaluated any correlation of Qc and
Γads with cycle number for pristine and anodized
areas of GC. In pristine areas (Figure S13a–c), there is only a slight variation in both Qc and Γads, likely from typical random experimental
variation. In contrast, a small but clear increment in Qc with cycling is observed in anodized regions (Figure S13d), alongside a significant increase
of Γads (Figure S13e).
By comparing the evolution of both parameters (normalized to the first
cycle, Figure S13f), the enhancement in
DA surface concentration is unambiguously higher than that for Qc. For instance, Qc and Γads increased by ca. 1.2× and 2.0×
up to the fifth cycle, respectively. The amount of electroactive DA
adsorbed thus genuinely increases with cycling on anodized GC, indicating
finite adsorption kinetics, probably associated with DA transport
to reach all the available electrode active sites on the nanostructured
surface.We now consider the relative DA surface concentration
on anodized
vs pristine areas, , accounting for specific surface area,
by using both the anodized/pristine ratio in Qc (ECSA) and surface roughness for normalization (Figure ). After correcting
by the Qc ratio, the DA surface concentration
for anodized GC is actually lower than that for pristine GC. For the
early cycles, the mass transport rate will contribute to this observation,
but limited mass transport from the SECCM pipet will not be a major
factor by the fifth cycle.
Figure 7
Variation of the ratio between Γads in anodized
and pristine GC as a function of voltammetric cycle number corrected
by the surface roughness ratio (blue trace) and the Qc ratio (red trace).
Variation of the ratio between Γads in anodized
and pristine GC as a function of voltammetric cycle number corrected
by the surface roughness ratio (blue trace) and the Qc ratio (red trace).The surface roughness (AFM) normalization produces
a slightly higher
relative DA surface concentration on anodized vs pristine GC (after
the third cycle), but it is clear from this analysis that anodization
and functionalization of the GC surface do not lead to significantly
enhanced DA specific adsorption and probably decrease the amount adsorbed
based on the specific surface area of anodized GC.
Effect of Anodization Time on Dopamine Adsorption and Reactivity
To further test whether surface anodization decreased the adsorption
efficiency of electroactive DA, the anodization time was increased
up to 300 s (i–t curve in Figure S14, yielding a total charge of 4.1 μC,
about 7× more than for 60 s anodization). Figure a shows five consecutive voltammetric cycles
for this GC surface, for which it can be seen that (1) capacitive
currents are significantly increased (ca. 90 pA at −0.375 V
vs Ag/AgCl QRCE) compared to those recorded after anodization for
60 s (ca. 35 pA), indicating that the ECSA has been further increased;
(2) relatively small DA oxidation and DAQ reduction currents are obtained
for the first cycle; and (3) DA oxidation and DAQ reduction currents
increased upon cycling, suggesting again that DA requires longer times
to adsorb on anodized regions. The spatially resolved SECCM experiments
highlight these differences for the electrochemistry of DA behavior
in pristine and anodized areas, as presented in Figure b,c where maps of Γads and
ΔEp for the fifth cycle are shown
and correlated to the identical location SEM image (Figure d). By further analyzing Γads, Qc ratio (as a measure of
ECSA enhancement), and ΔEp (kinetics),
the previous findings are further supported: surface anodization increases
the DA electron-transfer kinetics but lowers DA adsorption compared
to pristine GC when ECSA is accounted for. Thus, although the average
Γads (for the fifth cycle) was 300 ± 37 pmol
cm–2 on anodized areas compared to 58 ± 17
pmol cm–2 on pristine areas, the Qc ratio between anodized and pristine surface was ca.
11.2 (corrected for stray capacitance), and accounting for ECSA means
that Γads on the anodized surface is about half of
that found on pristine GC. This was significantly smaller than that
found for 60 s anodization, which was about 69% of that found on pristine
GC (fifth cycle). The DA flux from the pipet (vide supra) obviously becomes a more important factor for the rougher surface.
Figure 8
(a) CVs
(five cycles) obtained from one location of the SECCM measurement
where anodization was carried out for 300 s. (b) Spatially resolved
map of DA surface concentration (Γads). (c) Spatially
resolved map of the peak potential difference between DA oxidation
and DAQ reduction peaks (ΔEp). (d)
SEM image of the SECCM scan area covering pristine (darker) and anodized
for 300 s (brighter) regions. Maps contained 99 pixels (55 ×
45 μm2 with 5 μm as the hopping distance).
(a) CVs
(five cycles) obtained from one location of the SECCM measurement
where anodization was carried out for 300 s. (b) Spatially resolved
map of DA surface concentration (Γads). (c) Spatially
resolved map of the peak potential difference between DA oxidation
and DAQ reduction peaks (ΔEp). (d)
SEM image of the SECCM scan area covering pristine (darker) and anodized
for 300 s (brighter) regions. Maps contained 99 pixels (55 ×
45 μm2 with 5 μm as the hopping distance).Faster electron-transfer kinetics was also observed
on GC regions
anodized for 300 s, with even smaller values of ΔEp for DA electrochemistry when the anodization time was
longer: 0.36 ± 0.02 V (300 s anodization) compared to 0.43 ±
0.03 V for 60 s anodization (fifth voltammetric cycle). EDS measurements
detected a higher oxygen content (0.6 ± 0.1%) for 300 s anodization
compared to 0.05 ± 0.07% for pristine and 0.15 ± 0.05% for
30 s anodized areas (Figure S15). Interestingly,
DA surface concentration (normalized by ECSA increment) upon cycling
(Figure S16) increased at a similar rate
for 60 and 300 s anodization (4.5 ± 0.4 and 4.9 ± 0.3 pmol
cm–2 s–1, respectively). This
fact suggests that the normalized DA adsorption rate (in the period
from cycle 1 to cycle 5) is similar for both anodized surfaces and
the differences might be mainly due to an onset time required until
DA effectively reaches all active sites in rougher surfaces, with
this onset time being shorter on less rough surfaces.
Conclusions
SECCM with complementary co-located surface
characterization has
revealed how changes in the surface structure of a GC electrode after
anodization in acid affect DA adsorption and electrochemistry. Static-mode
SECCM was deployed to perform local surface anodization on a GC surface,
which was subsequently probed by spatially resolved voltammetric SECCM
to characterize both pristine and anodized regions within the same
electrochemical experiment. A fast scan rate and micromolar concentrations
of DA were used to work under conditions where adsorbed DA dominates
the electrochemical kinetics, revealing that both DA adsorption and
electrochemical kinetics were clearly affected by GC anodization.Anodization creates a significantly rougher and nanostructured
electrode than that found on pristine surfaces. This structural change
appeared to increase the time required for DA to adsorb on available
surface sites. Together with the increase in surface roughness detected
by AFM, anodized regions also show significantly higher ECSAs. Normalizing
the DA surface concentration by ECSA enhancement clearly shows that
anodization decreases the DA adsorption efficiency (i.e., actual surface
coverage) for the same time scale and conditions than on pristine
GC regions. The lower coverage at early times is, at least in part,
due to limited DA flux from the pipet. However, at longer times, there
are kinetic effects that might be associated with the restricted accessibility
of some adsorption sites. The overall lower cover of DA normalized
by ECSA is consistent with a lower graphitic carbon on the anodized
GC surface, where electroactive DA adsorption seems to take place.[11,32,43]DA electron-transfer kinetics
was notably enhanced on anodized
GC regions, with ΔEp values decreasing with increasing
times of anodization (60 vs 300 s). It is tempting to attribute enhanced
electron-transfer kinetics to a different interaction of DA with oxygenated
groups created on the GC surface, as a higher content of oxygen moieties
is detected at longer anodization times, although there is still a
proportion of the surface that is graphitic according to XPS data.
Increasing surface roughness in carbon materials without changes in
surface chemistry can also lead to apparent faster electron-transfer
kinetics.[70] A DA self-catalytic effect
is also observed on anodized GC as there was a decrease in ΔEp values with increasing DA surface concentration, thus confirming
that DA self-catalysis also occurs between adsorbed DA molecules and
not only between adsorbed and solution-based molecules.[69]In conclusion, this study reveals how
changes in the GC surface
nanostructure after anodization in acidic media control relevant phenomena
of DA reactivity on carbon surfaces: adsorption and electrochemical
kinetics. These results highlight the importance of considering factors
such as changes in ECSA or adsorption rates when comparing DA adsorption
in carbon electrodes with different roughness or porosity, as obtained
after anodization. Overall, this study also demonstrates the versatility
of SECCM for local modification of electrode surfaces and for resolving
surface structure–activity relationships in heterogeneous materials.
Authors: Pauli Virtanen; Ralf Gommers; Travis E Oliphant; Matt Haberland; Tyler Reddy; David Cournapeau; Evgeni Burovski; Pearu Peterson; Warren Weckesser; Jonathan Bright; Stéfan J van der Walt; Matthew Brett; Joshua Wilson; K Jarrod Millman; Nikolay Mayorov; Andrew R J Nelson; Eric Jones; Robert Kern; Eric Larson; C J Carey; İlhan Polat; Yu Feng; Eric W Moore; Jake VanderPlas; Denis Laxalde; Josef Perktold; Robert Cimrman; Ian Henriksen; E A Quintero; Charles R Harris; Anne M Archibald; Antônio H Ribeiro; Fabian Pedregosa; Paul van Mulbregt Journal: Nat Methods Date: 2020-02-03 Impact factor: 28.547