Literature DB >> 35982960

The clinical evaluation of atlas-based auto-segmentation for automatic contouring during cervical cancer radiotherapy.

Yi Li1, Wenjing Wu2, Yuchen Sun1, Dequan Yu3, Yuemei Zhang1, Long Wang1, Yao Wang1, Xiaozhi Zhang1, Yongkai Lu1.   

Abstract

Purpose: Our purpose was to investigate the influence of atlas library size and CT cross-slice number on the accuracy and efficiency of the atlas-based auto-segmentation (ABAS) method for the automatic contouring of clinical treatment volume (CTV) and organs at risk (OARs) during cervical cancer radiotherapy.
Methods: Of 140 cervical cancer patients, contours from 20, 40, 60, 80, 100, and 120 patients were selected incrementally to create six atlas library groups in ABAS. Another 20 tested patients were automatically contoured with the ABAS method and manually contoured by the same professional oncologist. Contours included CTV, bladder, rectum, femoral head-L, femoral head-R, and spinal cord. The CT cross-slice numbers of the 20 tested patients included 61, 65, 72, 75, 81, and 84. The index of dice similarity coefficients (DSCs) and Hausdorff distance (HD) were used to assess the consistency between ABAS automatic contouring and manual contouring. The randomized block analysis of variance and paired t-test were used for statistical analysis.
Results: The mean DSC values of "CTV, bladder, femoral head, and spinal cord" were all larger than 0.8. The femoral head and spinal cord showed a high degree of agreement between ABAS automatic contouring and manual contouring, with a mean DC >0.80 and HD <1 cm in all atlas library groups. A post-hoc least significant difference comparison indicated that no significant difference had been found between different atlas library sizes with DSC and HD values. For ABAS efficiency, the atlas library size had no effect on the time of ABAS automatic contouring. The time of automatic contouring increased slightly with the increase in CT cross-slice numbers, which were 99.9, 106.8, 114.0, 120.6, 127.9, and 134.8 s with CT cross-slices of 61, 65, 72, 75, 81, and 84, respectively.
Conclusion: A total of 20 atlas library sizes and a minimum CT cross-slice number including CTV and OARs are enough for ensuring the accuracy and efficiency of ABAS automatic contouring during cervical cancer radiotherapy.
Copyright © 2022 Li, Wu, Sun, Yu, Zhang, Wang, Wang, Zhang and Lu.

Entities:  

Keywords:  atlas; auto-segmentation; automatic contouring; cervical cancer; radiotherapy

Year:  2022        PMID: 35982960      PMCID: PMC9379286          DOI: 10.3389/fonc.2022.945053

Source DB:  PubMed          Journal:  Front Oncol        ISSN: 2234-943X            Impact factor:   5.738


Introduction

Radiotherapy, as an independent treatment strategy, plays an important role in cervical cancer treatment (1). Delineating the clinical target volume (CTV) and organs at risk (OARs) precisely is essential to ensuring the curative effect of radiotherapy. However, manual contouring is a time-consuming and complex process. Significant variance can be detected among contours that were delineated by different radiation oncologists or the same oncologist at different times (2–4). Compared with the manual segmentation process, atlas-based auto-segmentation (ABAS) could not only significantly save time but also reduce subjective bias among different radiation oncologists. In ABAS, segmented structures from the atlas library are propagated onto a subject image using the deformable image registration algorithm. Because multiple-ABAS uses a voting scheme for determining whether a voxel is inside or outside the structure, it is more susceptible to topological artifacts compared with single-ABAS (5). The atlas library should be set before applying the ABAS method for delineating contours automatically. According to published results, multiple-ABAS could overcome the issues encountered with single-ABAS, such as large discrepancies in volume and location between the atlas library and subject data (6). However, the atlas library size varied a lot in different cases and no authorized guideline could be taken as the reference (7–10). Although there are several reports about atlas library size in pelvic radiotherapy (11–13), especially for endometrial and cervical cancer (14), limited atlas library groups and fewer test cases were available on the impact of atlas library size on the accuracy and efficiency of ABAS, which may lead to an inaccurate conclusion. Rare works have researched the effect of CT cross-slice numbers on the ABAS-performed efficiency. Therefore, the aim of our study is to investigate the influence of the atlas library size and CT cross-slice number on the accuracy and efficiency of ABAS automatic contouring and establish an optimal strategy for ABAS with atlas library size and CT cross-slice number during cervical radiotherapy.

Material and methods

Patients

This retrospective study included 140 patients with newly diagnosed, pathologically confirmed stage II–III cervical cancer (7th edition of the AJCC staging system). All patients were treated with volume-modulated arc therapy (VMAT) technology in the Radiation Oncology Department at the First Affiliated Hospital of Xi’an Jiaotong University from October 2020 to October 2021. The VMAT plan was delivered at the prescribed dose of 50 Gy (25 fractions) to the cervical tumor. Neoadjuvant, concurrent, or adjuvant chemotherapy was recommended for patients.

CT simulation

A total of 140 planning CT images from 140 patients were collected. All patients were immobilized using thermoplastic body mold in the supine position with hands raised and arms crossed with elbows on the top of the head during CT simulation. All patients were instructed that the rectum should be completely empty and the bladder should be filled with 300 ml of water 2 h before CT scanning. Each patient received a helical CT scanning under free breathing conditions on a 16-slice CT scanner (Big Bore, Philips Medical Systems, Cleveland, OH). The scanning parameters were as follows: pixel spacing 1.1543 mm × 1.1543 mm, matrix 512 × 512, pitch 0.85, 120 kV, 400 mAs, thickness 3 mm, and layer spacing 3 mm. The scanned images were sent to a MIM Maestro version 6.7 software (Cleveland, OH, USA) with ABAS function based on a computer (Intel(R), Xeon(R), E5-1603 CPU, 2.8 GHz, four processors, 32 G RAM).

Manual contouring

The professional oncologist manually contoured CTV and OARs on the CT-scanned images of all patients with reference to RTOG 0418 (15) and consensus guidelines (16, 17). CTV included the tumor volume and whole pelvic nodal volume. OARs included the bladder, femoral head-L, femoral head-R, rectum, and spinal cord. CTV and OARs were delineated manually by the same professional oncologist with the mediastinum window setting (L = 40 Hu, W = 350 Hu) to make the interobserver lowest as soon as possible, which were used as the atlas library data and tested the segmentation ground truth.

Atlas library creation and automatic contouring

Of 140 cervical cancer patients, 120 patients were randomly registered in six different atlas library groups with 20, 40, 60, 80, 100, and 120 patients incrementally for ABAS. The automatic segmentation process was performed in the 20 remaining tested patients with ABAS. The details are shown in . During library construction, a template subject was assigned, and the remaining subjects were registered to the template subject separately. To minimize the bias and maintain the consistency of the registration alignment, an additional intervention during registration was prohibited. The ABAS algorithm automatically matched the atlas subject according to the input tested set. The optimal number of the matched atlas template was set to three during ABAS automatic contouring. Based on the intensity and the freeform cubic spline interpolation, contours of CTV and OARs were deformed, registered, and transferred to the test set. The CT cross-slice number of the selected automatically contoured patients ranged from 61 to 84 (the average number was 72 slices per patient). Then, manual correction of ABAS automatic contours was performed in the 20 tested patients.
Table 1

Characteristics of atlas library and tested patients.

TestN = 20Size of atlas library
N = 20N = 40N = 60N = 80N = 100N = 120
Mean age (SD)50.8 (11.3)52.1 (12.5)53.4 (12.2)53.8 (11.7)52.8 (12.3)51.8 (11.9)54.8 (12.6)
Mean height (SD), cm157.0 (7.4)158.0 (6.9)159.7 (6.4)157.4 (7.6)158.4 (6.9)157.4 (7.8)159.4 (7.5)
Mean weight (SD), kg62.7 (8.5)62.5 (7.1)61.3 (6.8)61.7 (7.5)62.9 (7.6)61.6 (8.3)62.7 (7.3)
Mean BMI (SD), kg/m2 25.4 (4.5)25.0 (4.3)24.0 (3.9)24.9 (4.1)25.1 (3.8)24.9 (4.2)24.7 (4.4)
Characteristics of atlas library and tested patients.

Quantitative evaluation of accuracy and efficiency of ABAS automatic contouring

Contours generated by ABAS automatic contours were compared with manually corrected ABAS automatic contours. The Dice similarity coefficient (DSC) and Hausdorff distance (HD) were used to evaluate the accuracy of automatic contouring (14). DSC was defined as DSC = 2|A∩B|/(A+B) with A equaling the volume of automatic contouring volume and B equaling the manual contouring volume. The results of DSC were between 0 and 1, where 0 represents no intersection and 1 reflects a perfect overlap of structures. In contrast, HD considered the degree of mismatch between two surfaces based on contour boundaries, eliminating the ambiguity of the volume-based DSC metric. Moreover, we timed the whole process to evaluate the efficiency of the ABAS method.

Statistical method

Random analysis of variance and paired-sample t-test were used to analyze the accuracy of automatic contouring results between the different atlas library sizes and CT cross-slice numbers. P < 0.05 was regarded as statistically significant. SPSS 22.0 was used for statistics analysis.

Results

DSC and HD values of contours of “CTV and OARs”

A total of 20 cervical cancer patients’ CTV and OARs were delineated both by a radiation oncologist manually and ABAS automatically with an atlas library size of 20. The consistency between automatic and manual segmentation was assessed with DSC and HD values. According to the results, the mean DSC values of “CTV, bladder, femoral head, and spinal cord” were all larger than 0.8. However, the mean DSC value and HD value of the rectum were 0.695 and 2.508 cm, respectively. Therefore, the contours of the rectum needed to be corrected greatly before clinical application as shown in and .
Figure 1

Variance between manual contours and ABAS automatic contours in CTV and OARs of cervical cancer patients with an atlas library size of 20 (A1, B1, C1: CTV contour comparison, A2, B2, C2: bladder contour comparison, A3, B3, C3: rectum contour comparison, A4, B4, C4: spinal cord comparison, A5, B5, C5: femoral head-L contour comparison, A6, B6, C6: femoral head-R contour comparison. Manual contours in red color, and automatic contours in green color).

Table 2

DSC and HD value of CTV and OARs with an atlas library size of 20.

StructureDSCHD (cm)
CTV0.816 ± 0.0462.195 ± 0.340
Bladder0.866 ± 0.0351.591 ± 0.340
Rectum0.685 ± 0.0482.508 ± 0.559
Femoral head-L0.867 ± 0.0390.843 ± 0.369
Femoral head-R0.873 ± 0.0470.789 ± 0.260
Spinal cord0.858 ± 0.0520.604 ± 0.205
Variance between manual contours and ABAS automatic contours in CTV and OARs of cervical cancer patients with an atlas library size of 20 (A1, B1, C1: CTV contour comparison, A2, B2, C2: bladder contour comparison, A3, B3, C3: rectum contour comparison, A4, B4, C4: spinal cord comparison, A5, B5, C5: femoral head-L contour comparison, A6, B6, C6: femoral head-R contour comparison. Manual contours in red color, and automatic contours in green color). DSC and HD value of CTV and OARs with an atlas library size of 20.

The influence of atlas library size on the accuracy of ABAS automatic segmentation

ABAS was used to delineate the contours of “CTV and OARs” of cervical cancer patients under different atlas library groups (20, 40, 60, 80, 100, and 120, respectively). The DSC and HD values of CTV and OARs in the different atlas library groups are shown in and . The results showed that different atlas library sizes had little impact on the accuracy of automatic contouring. Randomized block analysis of variance was adopted to further investigate the influence of atlas library size on the automatic contouring accuracy. Post-hoc least significant difference (LSD) comparisons indicated that no significant difference was found between different atlas library groups as shown in and . Therefore, an atlas library size of 20 was enough to delineate CTV and OARs automatically with the ABAS method during cervical patients’ radiotherapy.
Table 3

The DSC value of CTV and OARs in different atlas library groups (mean ± SD).

20406080100120
CTV0.816 ± 0.0460.818 ± 0.0460.819 ± 0.0490.814 ± 0.0360.819 ± 0.0610.810 ± 0.046
Bladder0.866 ± 0.0350.857 ± 0.0430.860 ± 0.0340.854 ± 0.0470.855 ± 0.0430.861 ± 0.046
Rectum0.685 ± 0.0480.682 ± 0.0410.693 ± 0.0420.689 ± 0.0480.682 ± 0.0480.692 ± 0.053
Femoral head-L0.867 ± 0.0390.868 ± 0.0470.865 ± 0.0370.875 ± 0.0460.864 ± 0.0460.870 ± 0.038
Femoral head-R0.873 ± 0.0470.865 ± 0.0410.870 ± 0.0450.867 ± 0.0420.869 ± 0.0460.879 ± 0.037
Spinal cord0.858 ± 0.0520.857 ± 0.0580.856 ± 0.0530.851 ± 0.0380.859 ± 0.0370.858 ± 0.051
Table 4

The HD value of CTV and OARs in different atlas library groups (mean ± SD, cm).

20406080100120
CTV2.195 ± 0.3402.335 ± 0.2232.310 ± 0.2652.345 ± 0.2552.363 ± 0.2752.074 ± 0.308
Bladder1.591 ± 0.3401.612 ± 0.2571.566 ± 0.3321.571 ± 0.2931.614 ± 0.2721.559 ± 0.298
Rectum2.045 ± 0.5622.097 ± 0.5541.967 ± 0.3811.956 ± 0.4012.039 ± 0.4291.925 ± 0.449
Femoral head-L0.843 ± 0.3690.727 ± 0.2300.774 ± 0.2040.690 ± 0.2170.725 ± 0.2970.730 ± 0.228
Femoral head-R0.789 ± 0.2600.730 ± 0.2350.700 ± 0.1400.635 ± 0.1850.698 ± 0.1950.673 ± 0.167
Spinal cord0.604 ± 0.2050.767 ± 0.3360.640 ± 0.2250.626 ± 0.2670.677 ± 0.2130.636 ± 0.161
Table 5

Results of post-hoc least significant difference (LSD) with DSC value among different atlas library groups.

AtlasgroupAtlasgroupCTVBladderRectumFemoral head-LFemoral head-RSpinal cord
20400.7530.6940.2910.5920.6100.240
600.5190.0940.4900.2370.4920.191
800.9540.3720.2680.8830.8770.062
1000.5080.2600.6440.3200.7050.199
1200.7450.8860.1040.5920.7220.163
40200.7530.6940.2910.5920.6100.240
600.7400.0400.7120.5140.8590.892
800.7970.2000.9580.6970.7220.477
1000.7270.1310.5510.6440.8950.910
1200.9910.5910.5581.0000.8770.820
60200.5190.0940.4900.2370.4920.191
400.7400.0400.7120.5140.8590.892
800.5560.4250.6730.2990.5940.565
1000.9860.5730.8190.8480.7570.982
1200.7490.1240.3420.5140.7400.928
80400.9540.3720.2680.8830.8770.062
600.7970.2000.9580.6970.7220.477
800.5560.4250.6730.2990.5940.565
1000.5450.8130.5160.3950.8230.550
1200.7880.4530.5940.6970.8410.628
100200.5080.2600.6440.3200.7050.199
400.7270.1310.5510.6440.8950.910
600.9860.5730.8190.8480.7570.982
800.5450.8130.5160.3950.8230.550
1200.7360.3250.2400.6440.9810.910
120200.7450.8860.1040.5920.7220.163
400.9910.5910.5581.0000.8770.820
600.7490.1240.3420.5140.7400.928
800.7880.4530.5940.6970.8410.628
1000.7360.3250.2400.6440.9810.910
Table 6

Results of post-hoc least significant difference (LSD) with HD value among different atlas library groups.

AtlasgroupAtlasgroupCTVBladderRectumFemoral head-LFemoralhead-RSpinal cord
20400.1950.8290.7230.1690.3560.064
600.2870.7890.6020.4130.1640.637
800.1640.8340.5510.0690.0670.773
1000.1200.8130.9700.1620.1530.340
1200.2610.7370.4210.1800.0710.675
40200.1950.8290.7230.1690.3560.064
600.8160.6290.3820.5740.6380.098
800.9220.6700.3430.6540.1380.067
1000.7910.9830.6960.9810.6100.240
1200.1170.5810.2480.9710.3720.088
60200.2870.7890.6020.4130.1640.637
400.8160.6290.3820.5740.6380.098
800.7410.9540.9410.3130.3090.854
1000.6180.6140.6280.5580.9690.628
1200.0600.9460.7770.5990.6720.958
80400.1640.8340.5510.0690.0670.773
600.9220.6700.3430.6540.1380.067
800.7410.9540.9410.3130.3090.854
1000.8670.6550.5760.6710.3280.504
1200.1130.9000.8340.6280.5510.896
100200.1200.8130.9700.1620.1530.340
400.7910.9830.6960.9810.6100.240
600.6180.6140.6280.5580.9690.628
800.8670.6550.5760.6710.3280.504
1200.1080.5670.4430.9520.7010.591
120200.2610.7370.4210.1800.0710.675
400.1170.5810.2480.9710.3720.088
600.0600.9460.7770.5990.6720.958
800.1130.9000.8340.6280.5510.896
1000.1080.5670.4430.9520.7010.591
The DSC value of CTV and OARs in different atlas library groups (mean ± SD). The HD value of CTV and OARs in different atlas library groups (mean ± SD, cm). Results of post-hoc least significant difference (LSD) with DSC value among different atlas library groups. Results of post-hoc least significant difference (LSD) with HD value among different atlas library groups.

Influence of atlas library size and CT cross-slice number on the efficiency of ABAS automatic contouring

One-way ANOVA was adopted to investigate the influence of atlas library size and CT cross-slice number on the efficiency of ABAS automatic contouring. The atlas library size had no effect on the time of ABAS automatic contouring, as shown in . The times of ABAS automatic contouring increased slightly with the increase in CT cross-slice numbers, which were 99.9, 106.8, 114.0, 120.6, 127.9, and 134.8 s with CT cross-slice numbers of 61, 65, 72, 75, 81, and 84, respectively, as shown in . As a result, a minimum CT cross-slice number was suggested for delineating the CTV and OARs automatically during cervical cancer radiotherapy.
Table 7

The time of ABAS automatic segmentation among different atlas library sizes.

Time (s)Range P value
20114.3108.7~119.9
40115.2109.2~121.1
60114.1100.2~128.10.974
80115.8103.9~127.8
100117.2104.2~130.1
120119.2105.8~136.7
Table 8

Time for ABAS automatic contouring among different CT cross-slice numbers.

CT cross-slice number616572758184P
Time (s)99.9106.8114.0120.6127.9134.80.032
The time of ABAS automatic segmentation among different atlas library sizes. Time for ABAS automatic contouring among different CT cross-slice numbers.

Discussion

Our study investigated the influence of atlas library size and patients’ CT cross-slice number on the accuracy and efficiency of ABAS and established an optimal atlas library and CT cross-slice for automatic contouring during cervical cancer radiotherapy, which was rarely discussed in previous studies. ABAS was introduced to delineate CTV and OARs automatically and reduce interobserver and intra-observer contouring variability. Previous studies (3, 18) demonstrated that contouring time could be reduced greatly using the ABAS method for head and neck cancer. Voet et al. (19) demonstrated that the delineation time was reduced from 180 to 66 min using the ABAS method despite necessary auto-contour editing. However, it should be noted that the manually corrected contouring times were difficult to assess accurately because manual correction times varied significantly with different oncologists or the same oncologist at different times. Therefore, we mainly focused on ABAS automatic contouring time without considering the manually corrected time. In clinical practice, it was a challenge to select the appropriate atlas library size. In our study, we found that a large atlas library size was not necessary for ABAS automatic contouring and an atlas library size of 20 could be enough to insure the accuracy of automatic contouring with the ABAS method. However, some authors validated ABAS based on a higher number of subjects for male pelvis CT images compared to what is concluded in the present article (20, 21). Some authors validated ABAS based on a lower number of subjects for prostate cancers if compared to what is concluded in the present article (7, 11). In addition, Ducote et al. concluded that the performance of ABAS was relatively insensitive to atlas size for various head and neck cancers (22). Kim et al. demonstrate that a different atlas library size had no impact on the accuracy of ABAS-OAR automatic contouring and the segmentation accuracy of ABAS-CTV improved with increasing library size with ABAS (14). In our opinion, the size of the atlas library is not an independent factor in determining the quality of auto-segmentation. DSC was used to assess the overlap ratio between ABAS automatic contouring and manual contouring. In our study, we found that ABAS showed acceptable accuracy in delineating CTV and parts of OARs such as bladder, femoral head-L, femoral head-R, and spinal cord, with the mean DSC of 0.816, 0.866, 0.867, 0.873, and 0.858, which was larger than a good overlap standard of 0.7 according to a published paper (8). The femoral head and spinal cord showed a high degree of agreement between ABAS automatic contouring and manual contouring, with a mean DC >0.80 and HD <1 cm in all atlas library groups, which was similar to the result by Kim et al. (14). For ABAS efficiency, we found that the atlas library size had no effect on the time of ABAS automatic contouring and automatic contouring time increased with the increase in CT cross-slice number. Therefore, we suggested a minimum CT cross-slice number, which could include CTV and OARs, for ABAS automatic contouring during cervical patient radiotherapy. Earlier work by Stuart Greenham et al. (12) evaluated the performance of ABAS automatic contouring, and the results showed that the bladder and CTV, which are the two largest structures in the pelvis, were delineated precisely in delineating the pelvic anatomy, which was similar with the results of our study. Among all the OARs, the bladder, femoral heads, and spinal cord achieved a higher DSC value and a lower HD value. This may be due to the relatively clear boundary and high contrast between these structures and the background. However, it should be noted that ABAS could not precisely delineate the rectum in this study. There are two reasons for this result. First, this could be caused by the unclear boundaries and the massive diversity in sizes, shapes, and locations for different patients. Even an experienced radiotherapy oncologist sometimes had to delineate the rectum boundary by experience instead of by images. To get accurate delineating results, manual corrections were suggested for rectum automatic contouring. In accordance with radiotherapy instructions, the rectum should be completely empty before CT scanning and the CT scanning time should be enough to acquire the images with contrast-enhanced ultrasound properly, which could improve the clarity of rectum boundaries and contouring accuracy. However, it was hard to control in clinical practice, which could result in poor automatic contouring and inaccurate manual contouring. Second, the atlas-based auto-segmentation method lacks necessary intervention methodologies and provides little final control by the medical doctor over the segmentation. Recently, auto-segmentation methodology with a user-defined template for the library construction could handle the variations in rectum anatomy. Luddemann et al. (23) have evaluated an interactive graph-based segmentation algorithm with a user-defined template by comparing the computer-assisted segmentation results with manual expert segmentation of the rectum/sigmoid colon and yielded a DSC of 83.58 ± 4.08% in gynecological brachytherapy. Therefore, auto-segmentation with a user-defined template can be used for rectosigmoid colon segmentation in gynecological external-beam radiation and gynecological brachytherapy. Recently, the scope of auto-segmentation has been expanded to arterial intelligence (AI)-based contouring using deep learning algorithms (24–29). Earlier work by Liu (30) demonstrated that the mean DSC values of deep learning-based methods were 0.924 for the bladder, 0.906 for the femoral head-L, 0.900 for the femoral head-R, 0.791 for the rectum, and 0.827 for the spinal cord. The results of ABAS in this study had comparable performance with deep learning methods in the spinal cord but an inferior performance in the bladder, rectum, femoral head-L, and femoral head-R. The deep learning-based method outperformed the ABAS method in OAR automatic contouring. However, many radiotherapy departments have to use ABAS to automatically contour the target area and normal organs due to a lack of deep learning equipment or condition. This study provided a method for selecting appropriate atlas library sizes and CT cross-slices for the departments with ABAS. There are several limitations in the current study. First, a cohort of patients was included in all the atlases used in six different atlas libraries. This pool could be overrepresented, and this issue could influence somehow the results of the work. Therefore, further investigations including a large number of independently tested patients are needed for evaluating the efficacy of the current ABAS library. Second, the research of this approach only evaluated the influence of CT cross-slice numbers on the time of ABAS automatic contouring. Future work will be required to evaluate the influence of CT cross-slice number on DSC and HD values of ABAS automatic contouring.

Conclusion

In our study, 20 atlases and a minimum CT cross-slice number could insure the accuracy and efficiency of ABAS automatic contouring during cervical cancer radiotherapy. Considering that ABAS could not delineate the rectum organ accurately, manual correction by a radiation oncologist is necessary. The data that we used in this study was from only one department, which means that the model may not apply to data with different situations. A larger dataset and more data sources could make the result more robust and have a better generalization capability.

Data availability statement

The original contributions presented in the study are included in the article/supplementary material. Further inquiries can be directed to the corresponding author/s.

Author contributions

WW and XZ planned and designed the research. YL, YS, and DY performed the experiment and wrote the manuscript. WW, YKL, and YZ revised the manuscript. YKL, LW, and YW analyzed the data. All authors contributed to the article and approved the submitted version.

Funding

This work was supported by the Key Research and Development Projects of Shaanxi Province, China (No. 2022SF-440).

Acknowledgments

All authors in this study and many colleagues helped to collect and analyze data. Their support and helps should be appreciated.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
  30 in total

1.  Simultaneous truth and performance level estimation (STAPLE): an algorithm for the validation of image segmentation.

Authors:  Simon K Warfield; Kelly H Zou; William M Wells
Journal:  IEEE Trans Med Imaging       Date:  2004-07       Impact factor: 10.048

2.  The utility of atlas-assisted segmentation in the male pelvis is dependent on the interobserver agreement of the structures segmented.

Authors:  K A Langmack; C Perry; C Sinstead; J Mills; D Saunders
Journal:  Br J Radiol       Date:  2014-08-29       Impact factor: 3.039

Review 3.  Vision 20/20: perspectives on automated image segmentation for radiotherapy.

Authors:  Gregory Sharp; Karl D Fritscher; Vladimir Pekar; Marta Peroni; Nadya Shusharina; Harini Veeraraghavan; Jinzhong Yang
Journal:  Med Phys       Date:  2014-05       Impact factor: 4.071

4.  Computerized Bone Age Estimation Using Deep Learning Based Program: Evaluation of the Accuracy and Efficiency.

Authors:  Jeong Rye Kim; Woo Hyun Shim; Hee Mang Yoon; Sang Hyup Hong; Jin Seong Lee; Young Ah Cho; Sangki Kim
Journal:  AJR Am J Roentgenol       Date:  2017-09-12       Impact factor: 3.959

5.  Does atlas-based autosegmentation of neck levels require subsequent manual contour editing to avoid risk of severe target underdosage? A dosimetric analysis.

Authors:  Peter W J Voet; Maarten L P Dirkx; David N Teguh; Mischa S Hoogeman; Peter C Levendag; Ben J M Heijmen
Journal:  Radiother Oncol       Date:  2011-01-25       Impact factor: 6.280

6.  Automatic segmentation of magnetic resonance images for high-dose-rate cervical cancer brachytherapy using deep learning.

Authors:  S A Yoganathan; Siji Nojin Paul; Satheesh Paloor; Tarraf Torfeh; Suparna Halsnad Chandramouli; Rabih Hammoud; Noora Al-Hammadi
Journal:  Med Phys       Date:  2022-02-09       Impact factor: 4.071

7.  Methodological approach to create an atlas using a commercial auto-contouring software.

Authors:  Marta Casati; Stefano Piffer; Silvia Calusi; Livia Marrazzo; Gabriele Simontacchi; Vanessa Di Cataldo; Daniela Greto; Isacco Desideri; Marco Vernaleone; Giulio Francolini; Lorenzo Livi; Stefania Pallotta
Journal:  J Appl Clin Med Phys       Date:  2020-11-25       Impact factor: 2.102

8.  Three-dimensional deep neural network for automatic delineation of cervical cancer in planning computed tomography images.

Authors:  Yi Ding; Zhiran Chen; Ziqi Wang; Xiaohong Wang; Desheng Hu; Pingping Ma; Chi Ma; Wei Wei; Xiangbin Li; Xudong Xue; Xiao Wang
Journal:  J Appl Clin Med Phys       Date:  2022-02-22       Impact factor: 2.102

9.  Clinical evaluation of multi-atlas based segmentation of lymph node regions in head and neck and prostate cancer patients.

Authors:  Carl Sjöberg; Martin Lundmark; Christoffer Granberg; Silvia Johansson; Anders Ahnesjö; Anders Montelius
Journal:  Radiat Oncol       Date:  2013-10-03       Impact factor: 3.481

10.  Reflections on the current status of commercial automated segmentation systems in clinical practice.

Authors:  Jonathan Sykes
Journal:  J Med Radiat Sci       Date:  2014-08-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.