Literature DB >> 35979783

[TiRobot-assisted percutaneous sacroiliac cannulated screw fixation for posterior pelvic ring injury with sacral variations].

Chengzhi Yang1, Gang Liu1, Jingli Tang1, Gaorong Li1, Xi Qin1, Juzheng Hu1.   

Abstract

Objective: To investigate the effectiveness of TiRobot-assisted percutaneous sacroiliac cannulated screw fixation in the treatment of posterior pelvic ring injuries with sacral variations, and to evaluate its feasibility and safety.
Methods: The clinical data of 7 patients with Tile type C pelvic fractures and sacral variations treated with TiRobot-assisted percutaneous sacroiliac cannulated screw fixation between January 2020 and June 2021 were retrospectively analyzed. There were 5 males and 2 females with an average age of 36 years (range, 17-56 years). The causes of injury were traffic accident in 4 cases and falling from height in 3 cases. According to Tile classification of pelvic fractures, there were 1 case of type C1.1, 1 case of type C1.2, and 5 cases of type C1.3; according to Denis classification of sacral fractures, there were 3 cases of zone Ⅰ and 4 cases of zone Ⅱ; sacral deformities included 3 cases of lumbar sacralization, 2 cases of sacral lumbarization, and 2 cases of accessory auricular surface of the sacrum. The time from injury to operation ranged from 2 to 7 days, with an average of 4.6 days. The implantation time of each screw, the fluoroscopy times of each guide pin, the quality of fracture reduction (according to Matta score), the excellent and good rate of screw position, the healing time of fracture, and the incidence of complications were recorded, and the effectiveness was evaluated by Majeed score.
Results: A total of 13 screws were implanted during the operation, the implantation time of each screw was 10-23 minutes, with an average of 18.2 minutes; the position of the guide pin was good, and no guide pin was adjusted, the fluoroscopy times of each guide pin were 3-7 times, with a median of 4 times. Postoperative imaging data at 3 days showed that the position of sacroiliac screw implantation was evaluated as excellent. No complication such as incision infection or vascular nerve injury occurred, and no adverse events related to robotic devices occurred. At 3 days after operation, according to Matta score, the quality of fracture reduction was excellent in 6 cases and good in 1 case, and the excellent and good rate was 100%. All the 7 patients were followed up 6-15 months, with an average of 12.4 months. Bone union was achieved in all patients, and the healing time ranged from 18 to 24 weeks, with an average of 21.2 weeks. Majeed score at last follow-up was 81-95, with an average of 91.5; 5 cases were excellent, 2 cases were good, and the excellent and good rate was 100%.
Conclusion: TiRobot-assisted percutaneous sacroiliac cannulated screw fixation for posterior pelvic ring injury with sacral variation is accurate, safe, minimally invasive, and intelligent, and the effectiveness is satisfactory.

Entities:  

Keywords:  TiRobot; internal fixation; posterior pelvic ring injury; sacral variation; sacroiliac cannulated screw

Mesh:

Year:  2022        PMID: 35979783      PMCID: PMC9379457          DOI: 10.7507/1002-1892.202204043

Source DB:  PubMed          Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi        ISSN: 1002-1892


  16 in total

Review 1.  Anatomy of the sacrum.

Authors:  Joseph S Cheng; John K Song
Journal:  Neurosurg Focus       Date:  2003-08-15       Impact factor: 4.047

2.  Percutaneous iliosacral screw insertion: malpositioning and revision rate of screws with regards to application technique (navigated vs. Conventional).

Authors:  J Zwingmann; G Konrad; A T Mehlhorn; N P Südkamp; M Oberst
Journal:  J Trauma       Date:  2010-12

3.  Quantification of the upper and second sacral segment safe zones in normal and dysmorphic sacra.

Authors:  Michael J Gardner; Saam Morshed; Sean E Nork; William M Ricci; Milton L Chip Routt
Journal:  J Orthop Trauma       Date:  2010-10       Impact factor: 2.512

4.  Variable morphology of the sacrum in a Chinese population.

Authors:  Li-Ping Wu; Yi-Kai Li; Yu-Ming Li; Ying-Qi Zhang; Shi-Zhen Zhong
Journal:  Clin Anat       Date:  2009-07       Impact factor: 2.414

5.  Indications for anterior fixation of pelvic fractures.

Authors:  J M Matta
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

6.  Robotic Technology in Orthopaedic Surgery.

Authors:  Antonia F Chen; Gregory S Kazarian; Galen W Jessop; Asim Makhdom
Journal:  J Bone Joint Surg Am       Date:  2018-11-21       Impact factor: 5.284

7.  Iliosacral screw fixation: early complications of the percutaneous technique.

Authors:  M L Routt; P T Simonian; W J Mills
Journal:  J Orthop Trauma       Date:  1997-11       Impact factor: 2.512

8.  Percutaneous transiliac pelvic fracture fixation: cadaver feasibility study and preliminary clinical results.

Authors:  Berton R Moed; Brian A Fissel; Gregory Jasey
Journal:  J Trauma       Date:  2007-02

9.  Closed reduction and percutaneous fixation of anterior column acetabular fractures.

Authors:  Adam C Crowl; David M Kahler
Journal:  Comput Aided Surg       Date:  2002

10.  Robot-assisted percutaneous screw placement combined with pelvic internal fixator for minimally invasive treatment of unstable pelvic ring fractures.

Authors:  Hua-Shui Liu; Sheng-Jun Duan; Shi-Dong Liu; Feng-Shuang Jia; Li-Ming Zhu; Min-Cen Liu
Journal:  Int J Med Robot       Date:  2018-06-19       Impact factor: 2.547

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.