Literature DB >> 35978747

Evaluating Visual Photoplethysmography Method.

Debjyoti Talukdar1, Luis Felipe de Deus2, Nikhil Sehgal2.   

Abstract

Regular monitoring of common physiological signs, including heart rate, blood pressure, and oxygen saturation, can be an effective way to either prevent or detect many kinds of chronic conditions. In particular, cardiovascular diseases (CVDs) are a worldwide concern. According to the World Health Organization, 32% of all deaths worldwide are from CVDs. In addition, stress-related illnesses cost $190 billion in healthcare costs per year. Currently, contact devices are required to extract most of an individual's physiological information, which can be uncomfortable for users and can cause discomfort. However, in recent years, remote photoplethysmography (rPPG) technology is gaining interest, which enables contactless monitoring of the blood volume pulse signal using a regular camera, and ultimately can provide the same physiological information as a contact device. In this paper, we propose a benchmark comparison using a new multimodal database consisting of 56 subjects where each subject was submitted to three different tasks. Each subject wore a wearable device capable of extracting photoplethysmography signals and was filmed to allow simultaneous rPPG signal extraction. Several experiments were conducted, including a comparison between information from contact and remote signals and stress state recognition. Results have shown that in this dataset, rPPG signals were capable of dealing with motion artifacts better than contact PPG sensors and overall had better quality if compared to the signals from the contact sensor. Moreover, the statistical analysis of the variance method had shown that at least two heart-rate variability (HRV) features, NNi 20 and SAMPEN, were capable of differentiating between stress and non-stress states. In addition, three features, inter-beat interval (IBI), NNi 20, and SAMPEN, were capable of differentiating between tasks relating to different levels of difficulty. Furthermore, using machine learning to classify a "stressed" or "unstressed" state, the models were able to achieve an accuracy score of 83.11%.
Copyright © 2022, Talukdar et al.

Entities:  

Keywords:  blood pressure; cardiovascular disease; heart rate variability; remote photoplethysmography; stress recognition

Year:  2022        PMID: 35978747      PMCID: PMC9375831          DOI: 10.7759/cureus.26871

Source DB:  PubMed          Journal:  Cureus        ISSN: 2168-8184


  4 in total

1.  Robust pulse rate from chrominance-based rPPG.

Authors:  Gerard de Haan; Vincent Jeanne
Journal:  IEEE Trans Biomed Eng       Date:  2013-06-04       Impact factor: 4.538

2.  Algorithmic Principles of Remote PPG.

Authors:  Wenjin Wang; Albertus C den Brinker; Sander Stuijk; Gerard de Haan
Journal:  IEEE Trans Biomed Eng       Date:  2016-09-13       Impact factor: 4.538

3.  Improvements in remote cardiopulmonary measurement using a five band digital camera.

Authors:  Daniel McDuff; Sarah Gontarek; Rosalind W Picard
Journal:  IEEE Trans Biomed Eng       Date:  2014-05-14       Impact factor: 4.538

Review 4.  Stress and Heart Rate Variability: A Meta-Analysis and Review of the Literature.

Authors:  Hye-Geum Kim; Eun-Jin Cheon; Dai-Seg Bai; Young Hwan Lee; Bon-Hoon Koo
Journal:  Psychiatry Investig       Date:  2018-02-28       Impact factor: 2.505

  4 in total
  1 in total

1.  Performance analysis of remote photoplethysmography deep filtering using long short-term memory neural network.

Authors:  Deivid Botina-Monsalve; Yannick Benezeth; Johel Miteran
Journal:  Biomed Eng Online       Date:  2022-09-19       Impact factor: 3.903

  1 in total