ABDOMINAL SUBCUTANEOUS FAT THICKNESS MEASURED BY ULTRASOUND AS A PREDICTOR OF TOTAL FAT MASS IN YOUNG- AND MIDDLE-AGED ADULTS.

Ş Ş Torgutalp1, F Korkusuz1.   

Abstract

Context: Predictive equations estimate total fat mass obtained from multiple-site ultrasound measurements; however, the predictive equation of total fat mass has not been investigated solely from abdominal subcutaneous fat thickness. Objective: To develop regression-based prediction equations using abdominal subcutaneous fat thickness for predicting fat mass, and to explore the validity of these predictive equations. Design: Cross-sectional study. Subjects and
Methods: Twenty-seven males and eighteen females were randomly divided into two groups as the model prediction and the validation. Total body fat mass was determined by dual-energy X-ray absorptiometry. The linear regression analysis was used to predict equations for total body fat mass from abdominal subcutaneous fat thickness acquired by ultrasound. Then, these predictive equations were tested on the validation group. Lin's concordance correlation coefficient (CCC) was used as a further measure of agreement.
Results: When fat mass prediction equations were tested on the validation groups, measured- and estimated-total fat masses in males (p=0.9) and females (p=0.5) were found similar. A good level of agreement between measurements in males (CCC=0.84) and females (CCC=0.76) was attained.
Conclusion: The abdominal subcutaneous fat thickness obtained from a single region by ultrasound might provide a non-invasive and quick evaluation. ©2021 Acta Endocrinologica (Buc).

Entities:  

Keywords:  anthropometry; body composition; concordance correlation coefficient; dual-energy X-ray absorptiometry

Year:  2022        PMID: 35975245      PMCID: PMC9365411          DOI: 10.4183/aeb.2022.58

Source DB:  PubMed          Journal:  Acta Endocrinol (Buchar)        ISSN: 1841-0987            Impact factor:   1.104


  18 in total

1.  Body fat percentage assessment by ultrasound subcutaneous fat thickness measurements in middle-aged and older adults.

Authors:  Robert S Thiebaud; Takashi Abe; Jeremy P Loenneke; Eiji Fujita; Takuya Akamine
Journal:  Clin Nutr       Date:  2018-11-30       Impact factor: 7.324

2.  Dual energy X-ray absorptiometry (DXA) reliability and intraobserver reproducibility for segmental body composition measuring.

Authors:  Osvaldo Costa Moreira; Claudia Eliza Patrocinio de Oliveira; José Antonio De Paz
Journal:  Nutr Hosp       Date:  2018-01-17       Impact factor: 1.057

3.  Ultrasonography Technique in Abdominal Subcutaneous Adipose Tissue Measurement: A Systematic Review.

Authors:  Alain J Azzi; Ann-Sophie Lafrenière; Mirko Gilardino; Thomas Hemmerling
Journal:  J Ultrasound Med       Date:  2018-09-12       Impact factor: 2.153

4.  Ultrasound measurement of subcutaneous adipose tissue thickness accurately predicts total and segmental body fat of young adults.

Authors:  Siobhan Leahy; Clodagh Toomey; Karen McCreesh; Cian O'Neill; Philip Jakeman
Journal:  Ultrasound Med Biol       Date:  2011-11-21       Impact factor: 2.998

5.  Measurement of fat thickness in man: a comparison of ultrasound, Harpenden calipers and electrical conductivity.

Authors:  R A Booth; B A Goddard; A Paton
Journal:  Br J Nutr       Date:  1966       Impact factor: 3.718

6.  Prediction and validation of total and regional skeletal muscle mass by ultrasound in Japanese adults.

Authors:  Kiyoshi Sanada; Charles F Kearns; Taishi Midorikawa; Takashi Abe
Journal:  Eur J Appl Physiol       Date:  2005-10-19       Impact factor: 3.078

7.  Validation of ultrasound techniques applied to body fat measurement. A comparison between ultrasound techniques, air displacement plethysmography and bioelectrical impedance vs. dual-energy X-ray absorptiometry.

Authors:  Jean-Claude Pineau; Anne-Marie Guihard-Costa; Michel Bocquet
Journal:  Ann Nutr Metab       Date:  2007-11-20       Impact factor: 3.374

Review 8.  Assessment methods in human body composition.

Authors:  Seon Yeong Lee; Dympna Gallagher
Journal:  Curr Opin Clin Nutr Metab Care       Date:  2008-09       Impact factor: 4.294

9.  Dual energy X-Ray absorptiometry body composition reference values from NHANES.

Authors:  Thomas L Kelly; Kevin E Wilson; Steven B Heymsfield
Journal:  PLoS One       Date:  2009-09-15       Impact factor: 3.240

Review 10.  Ultrasound as a tool to assess body fat.

Authors:  Dale R Wagner
Journal:  J Obes       Date:  2013-08-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.