Literature DB >> 3597494

Cardiopulmonary function and pulmonary microemboli during arthroplasty using cemented or non-cemented components. The role of intramedullary pressure.

E C Orsini, R J Byrick, J B Mullen, J C Kay, J P Waddell.   

Abstract

An experimental model was designed to investigate the role of intramedullary pressure on cardiopulmonary function and pulmonary pathology during arthroplasty using cemented and non-cemented components. Twenty-four dogs were divided randomly into three groups: a group that received a non-cemented implant in which low intramedullary pressure was generated, a group that received a cemented implant, and one that received bone wax and an implant; high intramedullary pressures were generated in the latter two groups. Bone wax was used to generate high intramedullary pressures without the use of bone cement. In the group with the non-cemented implant, few pulmonary microemboli and no significant cardiorespiratory changes were found. In the groups that received bone wax and an implant or the cemented implant, there were many pulmonary microemboli and significant cardiorespiratory changes, including decreased arterial oxygen tension, increased pulmonary arterial pressure, and increased intrapulmonary shunt fraction. There was no evidence that methylmethacrylate monomer was responsible for the cardiorespiratory changes in the group with the cemented implant.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3597494

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  31 in total

1.  Reversible catastrophic fat embolism: a case report.

Authors:  Kethy Jules-Elysee; Thomas P Sculco
Journal:  HSS J       Date:  2006-02

2.  The reamer/irrigator/aspirator reduces femoral canal pressure in simulated TKA.

Authors:  Cornel C Van Gorp; James V Falk; Stanley J Kmiec; Robert A Siston
Journal:  Clin Orthop Relat Res       Date:  2008-04-19       Impact factor: 4.176

3.  Bilateral total knee replacement under a single anaesthetic, using a cementless implant is not unsafe.

Authors:  Kalpesh Shah; Julie Smith; Bryn Jones; Michael Hullin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-08-26       Impact factor: 4.342

4.  The uncemented Bicontact total hip arthroplasty in octogenarians. Medium-term results.

Authors:  N P Badhe; R C Quinnell; P W Howard
Journal:  Eur J Orthop Surg Traumatol       Date:  2002-12-18

5.  Cardiac arrest during hip arthroplasty with cement gun.

Authors:  Kiyoshi Terasako
Journal:  J Anesth       Date:  1998-09       Impact factor: 2.078

6.  Intravenous methylmethacrylate following cemented total hip arthroplasty.

Authors:  E Brandser; G el-Khoury; M Riley; J Callaghan
Journal:  Skeletal Radiol       Date:  1995-10       Impact factor: 2.199

7.  Venting during prophylactic nailing for femoral metastases: current orthopedic practice.

Authors:  Dustin Dalgorf; Cornelia M Borkhoff; David J G Stephen; Joel Finkelstein; Hans J Kreder
Journal:  Can J Surg       Date:  2003-12       Impact factor: 2.089

8.  Bone cement implantation syndrome: a report of four cases.

Authors:  Pradeep Govil; P N Kakar; Deep Arora; Shibani Das; Nishkarsh Gupta; Deepak Govil; Sachin Gupta; Ashima Malohtra
Journal:  Indian J Anaesth       Date:  2009-04

9.  Pulmonary marrow embolism: a dog model simulating dual component cemented arthroplasty.

Authors:  R J Byrick; J C Kay; J B Mullen
Journal:  Can J Anaesth       Date:  1987-07       Impact factor: 5.063

10.  Risk Factor Analysis for 30-Day Mortality After Primary THA in a Single Institution.

Authors:  Fernando Comba; Ignacio Alonso Hidalgo; Martín Buttaro; Francisco Piccaluga
Journal:  HSS J       Date:  2012-06-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.