Comparison of diagnostic performances of slow-pull suction and standard suction in endoscopic ultrasound-guided fine needle biopsy for gastrointestinal subepithelial tumors.

Joon Seop Lee1, Chang Min Cho1, Yong Hwan Kwon1, An Na Seo2, Han Ik Bae2, Man-Hoon Han2.   

Abstract

BACKGROUND/AIMS: Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) is integral to the diagnosis of gastrointestinal (GI) subepithelial tumors (SETs). The impact of different EUS-FNB tissue sampling techniques on specimen adequacy and diagnostic accuracy in SETs has not been fully evaluated. This study aimed to compare the diagnostic outcomes of slow-pull (SP) and standard suction (SS) in patients with GI SETs.
METHODS: In this retrospective comparative study, 54 patients were enrolled. Medical records were reviewed for location and size of the target lesion, FNB needle type/size, technical order, specimen adequacy, diagnostic yield, and adverse events. The acquisition rate of adequate specimens and diagnostic accuracy were compared according to EUS-FNB techniques.
RESULTS: The mean lesion size was 42.6±36.4 mm, and most patients were diagnosed with GI stromal tumor (75.9%). The overall diagnostic accuracies of the SP and SS techniques were 83.3% and 81.5%, respectively (p=0.800). The rates of obtaining adequate core tissue were 79.6% and 75.9%, respectively (p=0.799). No significant clinical factors affected the rate of obtaining adequate core tissue, including lesion location and size, FNB needle size, and final diagnosis.
CONCLUSION: SP and SS had comparable diagnostic accuracies and adequate core tissue acquisition for GI SETs via EUS-FNB.

Entities:  

Keywords:  Biopsy; Endoscopic ultrasonography; Fine needle aspiration; Gastrointestinal stromal tumors

Year:  2022        PMID: 35973440      PMCID: PMC9539288          DOI: 10.5946/ce.2021.257

Source DB:  PubMed          Journal:  Clin Endosc        ISSN: 2234-2400


  32 in total

1.  Diagnostic efficacy of endoscopic ultrasound-guided needle sampling for upper gastrointestinal subepithelial lesions: a meta-analysis.

Authors:  Xiao-Cen Zhang; Quan-Lin Li; Yong-Fu Yu; Li-Qing Yao; Mei-Dong Xu; Yi-Qun Zhang; Yun-Shi Zhong; Wei-Feng Chen; Ping-Hong Zhou
Journal:  Surg Endosc       Date:  2015-08-27       Impact factor: 4.584

2.  Accuracy of EUS in the evaluation of small gastric subepithelial lesions.

Authors:  Cetin Karaca; Brian G Turner; Sevdenur Cizginer; David Forcione; William Brugge
Journal:  Gastrointest Endosc       Date:  2010-02-19       Impact factor: 9.427

Review 3.  Endoscopic ultrasound guided fine needle aspiration and useful ancillary methods.

Authors:  Mario Tadic; Tajana Stoos-Veic; Rajko Kusec
Journal:  World J Gastroenterol       Date:  2014-10-21       Impact factor: 5.742

4.  EUS-guided fine-needle biopsy sampling versus FNA in the diagnosis of subepithelial lesions: a large multicenter study.

Authors:  Diogo T H de Moura; Thomas R McCarty; Pichamol Jirapinyo; Igor B Ribeiro; Victor K Flumignan; Fedaa Najdawai; Marvin Ryou; Linda S Lee; Christopher C Thompson
Journal:  Gastrointest Endosc       Date:  2020-02-25       Impact factor: 9.427

5.  Endoscopic ultrasonography-guided biopsy using a Franseen needle design: Initial assessment.

Authors:  Ji Young Bang; Shantel Hebert-Magee; Muhammad K Hasan; Udayakumar Navaneethan; Robert Hawes; Shyam Varadarajulu
Journal:  Dig Endosc       Date:  2016-12-20       Impact factor: 7.559

6.  Prospective comparison of endoscopic ultrasound-guided fine-needle aspiration and surgical histology in upper gastrointestinal submucosal tumors.

Authors:  M Philipper; S Hollerbach; H E Gabbert; S Heikaus; A Böcking; N Pomjanski; H Neuhaus; T Frieling; B Schumacher
Journal:  Endoscopy       Date:  2010-03-19       Impact factor: 10.093

7.  Endoscopic ultrasound-guided tissue sampling of small subepithelial tumors of the upper gastrointestinal tract with a 22-gauge core biopsy needle.

Authors:  Christoph Schlag; Christoph Menzel; Manuela Götzberger; Simon Nennstiel; Peter Klare; Stefan Wagenpfeil; Roland M Schmid; Gregor Weirich; Stefan von Delius
Journal:  Endosc Int Open       Date:  2017-03

8.  Prognostic value of tumor necrosis in gastrointestinal stromal tumor: A meta-analysis.

Authors:  Mengshi Yi; Lin Xia; Yan Zhou; Xiaoting Wu; Wen Zhuang; Yi Chen; Rui Zhao; Qianyi Wan; Liang Du; Yong Zhou
Journal:  Medicine (Baltimore)       Date:  2019-04       Impact factor: 1.817

9.  Feasibility of a 20-gauge ProCore needle in EUS-guided subepithelial tumor sampling: a prospective multicenter study.

Authors:  Do Hoon Kim; Gwang Ha Kim; Chang Min Cho; Chang Hwan Park; Soo-Young Na; Tae Hyeon Kim; Yu Kyung Cho; Ji Hyun Kim; Dong-Wan Seo
Journal:  BMC Gastroenterol       Date:  2018-10-19       Impact factor: 3.067

10.  Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline - Updated January 2017.

Authors:  Jean-Marc Dumonceau; Pierre H Deprez; Christian Jenssen; Julio Iglesias-Garcia; Alberto Larghi; Geoffroy Vanbiervliet; Guruprasad P Aithal; Paolo G Arcidiacono; Pedro Bastos; Silvia Carrara; László Czakó; Gloria Fernández-Esparrach; Paul Fockens; Àngels Ginès; Roald F Havre; Cesare Hassan; Peter Vilmann; Jeanin E van Hooft; Marcin Polkowski
Journal:  Endoscopy       Date:  2017-05-16       Impact factor: 10.093