Literature DB >> 35968987

Tooth enamel ESR dosimetry for Hiroshima 'black rain' zone residents.

Kassym Zhumadilov1, Alexander Ivannikov2, Valeriy Stepanenko2, Shin Toyoda3, Polat Kazymbet4, Andrey Kaprin2, Sergey Ivanov2, Peter Shegay2,5, Satoru Endo2,5, Masaharu Hoshi2,5.   

Abstract

Electron spin resonance (ESR) dosimetry was applied to human tooth enamel in order to obtain individual absorbed doses for victims of the Hiroshima bomb who lived in the 'black rain' area. The so-called 'black rain' fell in the form of precipitation on the western part of Hiroshima city and the northwestern suburbs within a few hours after the explosion of the atomic bomb on 6 August 1945, and exposed the population in this area. Only three tooth samples were collected from this area. Since the teeth were located at positions 1, 2 and 4, only the lingual portion was used for the analysis. The results showed that the excess dose after subtracting natural radiation for one (position 4; hh1) was background, for the second (position 2; hh2) it was 133 mGy, and for the other (position 1; hh3) it was 243 mGy. Based on these results, we further investigated the radiation dose attributed to dental X-rays and head CT scan. Such dose of the hh3 radiographic examination was estimated to be 57-160 mGy, which implies an additional exposure around 135 mGy after subtraction. On the other hand, the dose data of hh1 after subtracting dental X-rays was negative. This may mean that such additional doses are an overestimation. In addition, the effect of sunlight should be considered, which is the same direction of overestimation. As a result, the residual dose of 140 mGy suggests the inclusion of radiation from the 'black rain.'
© The Author(s) 2022. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

Entities:  

Keywords:  Hiroshima; absorbed dose; electron spin resonance (ESR); retrospective dosimetry; tooth enamel

Mesh:

Year:  2022        PMID: 35968987      PMCID: PMC9377024          DOI: 10.1093/jrr/rrac024

Source DB:  PubMed          Journal:  J Radiat Res        ISSN: 0449-3060            Impact factor:   2.438


  11 in total

1.  Calibration of EPR signal dose response of tooth enamel to photons: experiment and Monte Carlo simulation.

Authors:  A I Ivannikov; D D Tikunov; N B Borysheva; F Trompier; V G Skvortsov; V F Stepanenko; M Hoshi
Journal:  Radiat Prot Dosimetry       Date:  2004       Impact factor: 0.972

Review 2.  EPR dosimetry with tooth enamel: A review.

Authors:  Paola Fattibene; Freddy Callens
Journal:  Appl Radiat Isot       Date:  2010-06-04       Impact factor: 1.513

3.  Results of EPR dosimetry for population in the vicinity of the most contaminating radioactive fallout trace after the first nuclear test in the Semipalatinsk test site.

Authors:  Alexander Ivannikov; Kassym Zhumadilov; Eldana Tieliewuhan; Ling Jiao; Dinara Zharlyganova; Kazbek N Apsalikov; Gulnara Berekenova; Zhaxybay Zhumadilov; Shin Toyoda; Chuzou Miyazawa; Valeriy Skvortsov; Valeriy Stepanenko; Satoru Endo; Kenichi Tanaka; Masaharu Hoshi
Journal:  J Radiat Res       Date:  2006-02       Impact factor: 2.724

4.  Comparison of EPR occupational lifetime external dose assessments for Mayak nuclear workers and film badge dose data.

Authors:  A Wieser; E Vasilenko; P Fattibene; S Bayankin; N El-Faramawy; D Ivanov; P Jacob; V Knyazev; S Onori; M C Pressello; A Romanyukha; M Smetanin; A Ulanovsky
Journal:  Radiat Environ Biophys       Date:  2006-02-03       Impact factor: 1.925

5.  Tooth enamel EPR dosimetry: optimization of EPR spectra recording parameters and effect of sample mass on spectral sensitivity.

Authors:  Kassym Zhumadilov; Alexander Ivannikov; Valeriy Skvortsov; Valeriy Stepanenko; Zhaxybay Zhumadilov; Satoru Endo; Kenichi Tanaka; Masaharu Hoshi
Journal:  J Radiat Res       Date:  2005-12       Impact factor: 2.724

6.  Measurement of absorbed doses from X-ray baggage examinations to tooth enamel by means of ESR and glass dosimetry.

Authors:  Kassym Zhumadilov; Valeriy Stepanenko; Alexander Ivannikov; Zhaxybay Zhumadilov; Dinara Zharlyganova; Shin Toyoda; Kenichi Tanaka; Satoru Endo; Masaharu Hoshi
Journal:  Radiat Environ Biophys       Date:  2008-07-23       Impact factor: 1.925

7.  Dental enamel EPR dosimetry: comparative testing of the spectra processing methods for determination of radiation-induced signal amplitude.

Authors:  A I Ivannikov; D Sanin; M Nalapko; V F Skvortsov; V F Stepanenko; A F Tsyb; F Trompier; K Zhumadilov; M Hoshi
Journal:  Health Phys       Date:  2010-02       Impact factor: 1.316

8.  ESR dosimetry study on population of settlements nearby Ust-Kamenogorsk city, Kazakhstan.

Authors:  Kassym Zhumadilov; Alexander Ivannikov; Dinara Zharlyganova; Zhaxybay Zhumadilov; Valeriy Stepanenko; Kazbek Apsalikov; Mohd Rodzi Ali; Anara Zhumadilova; Shin Toyoda; Satoru Endo; Kenichi Tanaka; Tetsuji Okamoto; Masaharu Hoshi
Journal:  Radiat Environ Biophys       Date:  2009-06-26       Impact factor: 1.925

9.  Radiation dose estimation by tooth enamel EPR dosimetry for residents of Dolon and Bodene.

Authors:  Kassym Zhumadilov; Alexander Ivannikov; Kazbek N Apsalikov; Zhaxybay Zhumadilov; Shin Toyoda; Dinara Zharlyganova; Eldana Tieliewuhan; Satoru Endo; Kenichi Tanaka; Chuzou Miyazawa; Tetsuji Okamoto; Masaharu Hoshi
Journal:  J Radiat Res       Date:  2006-02       Impact factor: 2.724

10.  Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer.

Authors:  Rebecca Smith-Bindman; Jafi Lipson; Ralph Marcus; Kwang-Pyo Kim; Mahadevappa Mahesh; Robert Gould; Amy Berrington de González; Diana L Miglioretti
Journal:  Arch Intern Med       Date:  2009-12-14
View more
  1 in total

1.  The overview of neutron-induced 56Mn radioactive microparticle effects in experimental animals and related studies.

Authors:  Masaharu Hoshi
Journal:  J Radiat Res       Date:  2022-08-13       Impact factor: 2.438

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.