| Literature DB >> 35957445 |
Giulia Zambotti1,2,3, Rosamaria Capuano4, Valentina Pasqualetti4, Matteo Soprani1,3, Emanuela Gobbi1,5, Corrado Di Natale4, Andrea Ponzoni1,2,3.
Abstract
The realization of an unobtrusive and effective technology able to track fish freshness in real time and inform on its edibility is highly demanded, but still unachieved. In the present paper, we address this issue through a single metal oxide gas sensor working in temperature modulation mode. The system can work without an external reference air source, which is an appealing feature for its possible integration in domestic refrigerators. Tests were carried out using fresh sea bream fillets as case study and working both inside the refrigerator and at room temperature. Parallel gas chromatography-mass spectrometry and microbiological characterization indicated the marked dependence of both the microbiological condition and the gas-phase composition from the individual sample and from the storage temperature. Despite such a large variability, which may be expected in real applications, the proposed system provided similar responses whenever the total bacterial population approached and exceeded the edibility threshold of 107 CFU/g.Entities:
Keywords: fish; gas chromatography–mass spectrometry; gas sensor; metal oxide; microbiological count; temperature modulation
Mesh:
Substances:
Year: 2022 PMID: 35957445 PMCID: PMC9371398 DOI: 10.3390/s22155888
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.847
Figure 1Measurement setup (a). The sensing system is lodged inside a beaker containing the target sample. Picture of the sensing system device (b).
Tested samples and main parameters of status, namely, the storage and testing conditions and the initial and final total viable counts (TVC). The TVC values were determined following the procedure described in Section 2.3.
| Sample | Initial TVC (CFU/g) | Final TVC (CFU/g) | Storage and Testing Condition |
|---|---|---|---|
| Fish1 | 1 × 104 | 3 × 104 @ 24 h | Thermostatic chamber @ 25 °C |
| Fish2 | 3 × 105 | 6 × 107 @ 24 h | Thermostatic chamber @ 25 °C |
| Fish3 | 5 × 106 | 2 × 109 @ 32 h | Refrigerator @ 4 °C |
| Fish4 | 5 × 106 | 3 × 107 @ 32 h | Refrigerator @ 4 °C |
| Sterilized Water | <1 | <1 @ 32 h | Thermostatic chamber @ 25 °C |
| Air | Not performed | Not performed | Thermostatic chamber @ 25 °C |
| Air | Not performed | Not performed | Refrigerator @ 4 °C |
Figure 2Sensor resistance vs. time curves acquired during sensor exposure to air (a) and to the headspace of a fish sample at the storage time of 14 h (b). In both cases, experiments were carried out inside the refrigerator (4 °C). The modulation of the heater voltage is also shown. Full circles in (a) indicate the resistance values used to extrapolate parameters (features) that resume the shape of the curve (see text for details).
SPME-GC/MS analysis of fish samples’ headspace. List of volatile organic compounds (VOCs) most correlated with sample degradation. For each VOC, the retention time, the CAS number (°# CAS) and the reference mass spectra similarity are specified. In the Samples column, R indicates samples stored and analyzed at 25 °C, while F indicates samples stored at 4 °C and analyzed at room temperature (25 °C).
| Number | Retention Time (min) | Putative Identification | °# CAS | Reference Mass Spectra Similarity (%) | Samples |
|---|---|---|---|---|---|
| 1 | 5.160 | 3-methyl-1-butanol | 123-51-3 | 92 | R; F |
| 2 | 5.306 | dimethyl disulfide | 624-92-0 | 94 | R |
| 3 | 7.293 | 3-pentanone | 96-22-0 | 80 | R; F |
| 4 | 8.927 | 2,3-heptanedione | 96-04-8 | 91 | R |
| 5 | 9.259 | ethyl crotonate | 10544-63-5 | 95 | R |
| 6 | 9.626 | ethyl isovalerate | 108-64-5 | 92 | R; F |
| 7 | 10.627 | 2-heptanone | 110-43-0 | 88 | R; F |
| 8 | 11.987 | ethyl tiglate | 5837-78-5 | 93 | R |
| 9 | 12.555 | dimethyl trisulfide | 3658-80-8 | 91 | R |
| 10 | 13.024 | phenol | 108-95-2 | 96 | R; F |
| 11 | 13.340 | ethyl hexanoate | 123-66-0 | 97 | R; F |
| 12 | 15.153 | 1-undecene | 821-95-4 | 91 | R; F |
| 13 | 18.611 | indole | 120-72-9 | 87 | R |
Figure 3SPME-GC/MS analysis of fish samples stored at 4 °C and 25 °C. Time dependence of the abundance of the most meaningful compounds (see text for details) present in the headspace for fish stored at room temperature (25 °C) and inside the fridge (4 °C).
Figure 4SPME-GC/MS analysis of meaningful compounds found only in the headspace of fish stored at room temperature (25 °C), related to storage time.
Figure 5Microbiological characterization of fish samples: time dependence of the total viable count (TVC). Dashed lines are guides for the eye.
Figure 6Principal component analysis (PCA) plot showing the time dependence of the device response and its correlation with selected air, water, and fish samples measured at different temperatures. For the sake of clarity, only five samples are shown; each sample is measured for a period lasting between 24 and 36 h. (a) Colors and symbols are used to distinguish different samples and temperatures, respectively. Dashed arrows indicate the time direction for fish samples. (b) The color-bar identifies the measurement time for all samples, symbols identify different samples.
Figure 7Principal component analysis (PCA) plot showing the correlation between the sensor signal and the microbiological characterization (TVC). (a) Full dataset for fish samples, dashed arrows indicate the time direction for each sample. (b) Subsample data (see text for details) showing the correlation between the score plot and the respective total viable count (TVC).