Literature DB >> 3595640

The use of a computer in ventilation-perfusion scintigraphy with Tc-99m macroaggregates and Kr-81m, to obtain a physiological model.

H J Teertstra, P J Janssen, C Posch, W P Verdegaal.   

Abstract

In this article we describe a computer program to demonstrate ventilation-perfusion relationships in the lungs, using 99mTc-MAA and 81mKr, with the patients sitting upright, the normal physiological situation. The ventilation and perfusion scans are performed simultaneously with both gamma camera and computer adjusted for dual isotope mode. Steady state images are acquired in the frontal, dorsal, and left and right posterior oblique positions. Additionally, in the dorsal and frontal projections, a sequence of 12 washout images (5 s) is registered, after closing the Krypton supply. After normalization and further computer processing, the following parameters are calculated in the frontal and dorsal projections, in the whole lung and in four horizontal subregions: washout values, ventilation-perfusion ratios, left to right ratios of ventilation and perfusion, and left to right ratios of the average pixel values for ventilation and perfusion. Results in a group of eight healthy volunteers are described and discussed.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3595640     DOI: 10.1007/bf00252641

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  12 in total

1.  Assessment of regional ventilation by continuous inhalation of radioactive krypton-81m.

Authors:  F Fazio; T Jones
Journal:  Br Med J       Date:  1975-09-20

2.  Effect of 'unilateral hypoxia' on pulmonary blood flow distribution in normal subjects.

Authors:  J G DEFARES; G LUNDIN; M ARBORELIUS; R STROMBLAD; L SVANBERG
Journal:  J Appl Physiol       Date:  1960-01       Impact factor: 3.531

3.  Influence of posture on the lung volumes, ventilation and circulation in normals; a spirometric-bronchospirometric investigation.

Authors:  L SVANBERG
Journal:  Scand J Clin Lab Invest       Date:  1957       Impact factor: 1.713

4.  State of the art: ventilation-perfusion relationships.

Authors:  J B West
Journal:  Am Rev Respir Dis       Date:  1977-11

5.  Effect of posture on inter-regional distribution of pulmonary perfusion and VA/Q ratios in man.

Authors:  T C Amis; H A Jones; J M Hughes
Journal:  Respir Physiol       Date:  1984-05

6.  Pulmonary physiology, pathology, and ventilation-perfusion studies.

Authors:  R H Secker-Walker
Journal:  J Nucl Med       Date:  1978-08       Impact factor: 10.057

7.  81mKr gas and 99mTc-MAA V/Q ratio images for detection of V/Q mismatches.

Authors:  E L Kramer; J J Sanger
Journal:  Eur J Nucl Med       Date:  1984

8.  Computer processing of perfusion, ventilation, and V/Q images to highlight pulmonary embolism.

Authors:  J E Arnold; B C Wilson
Journal:  Eur J Nucl Med       Date:  1981

9.  Regional distribution of VA/Q in man at rest and with exercise measured with krypton-81m.

Authors:  A Harf; T Pratt; J M Hughes
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1978-01

10.  Krypton-81m as a flow tracer in the lung: theory and quantitation.

Authors:  T C Amis; T Jones
Journal:  Bull Eur Physiopathol Respir       Date:  1980 May-Jun
View more