Literature DB >> 35951123

Effect of nanosecond- and microsecond-pulse Er,Cr:YSGG laser ablation on dentin shear bond strength of universal adhesives.

Zhengdong Xiong1,2, Shanshan Tu3, Lingling Jiang1,2, Tingqing Cheng1, Haihe Jiang4,5.   

Abstract

OBJECTIVE: The study aimed to evaluate the bond strength of universal adhesives to dentin after Er,Cr:YSGG laser irradiation with nanosecond-domain and microsecond-domain pulses.
METHODS: Eighty extracted caries-free, sound human molars were divided into eight groups. The enamel was removed until the dentin occlusal flat dentin surface was exposed. Etch-and-rinse followed by adhesive was applied to group 1, and a self-etch adhesive was applied to group 2. Er,Cr:YSGG laser (3 mJ, 100 Hz, 100 ns), (3 mJ, 100 Hz, 150 μs), and (20 mJ, 100 Hz, 150 μs) were applied to groups 3-4, 5-6, and 7-8, respectively. The laser preparation was followed by self-etch adhesives or adhesives treatment. When the composite resin had been built up on the samples, the shear bond strength was tested, and the data were statistically analyzed using analysis of variance (ANOVA).
RESULTS: Groups prepared with nanosecond-pulse laser showed significantly higher bond strength values than the microsecond-pulse laser groups and self-etch mode group, and the SEM photographs also showed more dentinal tubules and no damage in the ablation area. The shear bond strength of long pulse laser ablated was comparable to that of self-etching system when it was combined with a self-etch adhesive at low energy, but higher energy laser degraded shear bond strength.
CONCLUSIONS: The pulse width of Er,Cr:YSGG laser affects the bond strength, nanosecond pulses of laser irradiation without water cooling can enhance bond strength, but microsecond pulses of laser cannot enhance bond strength.
© 2022. The Author(s), under exclusive licence to Springer-Verlag London Ltd., part of Springer Nature.

Entities:  

Keywords:  Dentin morphology; Dentin tissue; Er,Cr:YSGG laser; Q-switching laser; Shear bond strength

Mesh:

Substances:

Year:  2022        PMID: 35951123     DOI: 10.1007/s10103-022-03625-w

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   2.555


  17 in total

1.  Comparison of microtensile bond strength of a resin composite to enamel conditioned by acid etching and Er,Cr:YSGG laser in human primary teeth.

Authors:  B Malekafzali; R Fekrazad; A Mirfasihi; S Saedi
Journal:  Eur Arch Paediatr Dent       Date:  2014-11-01

2.  Microtensile bond strength analysis of different adhesive systems and dentin prepared with high-speed and Er:YAG laser: a comparative study.

Authors:  Denise Cerqueira Oliveira; Lussara Azevedo Manhães; Márcia Martins Marques; Adriana Bona Matos
Journal:  Photomed Laser Surg       Date:  2005-04       Impact factor: 2.796

3.  Shear bond strength and SEM evaluation of composite bonded to Er:YAG laser-prepared dentin and enamel.

Authors:  William J Dunn; John T Davis; Anneke C Bush
Journal:  Dent Mater       Date:  2005-07       Impact factor: 5.304

4.  Influence of the water content in dental enamel and dentin on ablation with erbium YAG and erbium YSGG lasers.

Authors:  Jörg Meister; René Franzen; Katharina Forner; Henning Grebe; Sven Stanzel; Friedrich Lampert; Christian Apel
Journal:  J Biomed Opt       Date:  2006 May-Jun       Impact factor: 3.170

5.  Controlling dental enamel-cavity ablation depth with optimized stepping parameters along the focal plane normal using a three axis, numerically controlled picosecond laser.

Authors:  Fusong Yuan; Peijun Lv; Dangxiao Wang; Lei Wang; Yuchun Sun; Yong Wang
Journal:  Photomed Laser Surg       Date:  2015-02       Impact factor: 2.796

6.  Effects of Dentin Ablation by a Q-Switching Er:YSGG Laser with a High Pulse Repetition Rate.

Authors:  Qingzhe Cui; Mengen Wei; Zhengdong Xiong; Shuwu Hu; Jiantao Jiang; Li Wang; Tingqing Cheng; Xianyou Wu; Haihe Jiang
Journal:  Photobiomodul Photomed Laser Surg       Date:  2020-12-09

7.  Effects of the percentage of air/water in spray on the efficiency of tooth ablation with erbium, chromium: yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser irradiation.

Authors:  Koichi Shinkai; Mayo Takada; Satoki Kawashima; Masaya Suzuki; Shiro Suzuki
Journal:  Lasers Med Sci       Date:  2018-08-08       Impact factor: 3.161

8.  Optical changes of human dentin after non-vital bleaching and effect of Er,Cr:YSGG laser on micro-shear bond strength of a self-etch and an etch-and-rinse adhesive system.

Authors:  İzgen Karakaya; Tağmaç Özberk
Journal:  Lasers Med Sci       Date:  2020-06-23       Impact factor: 3.161

9.  Erbium, Chromium:Yttrium-Scandium-Gallium-Garnet Laser for Root Conditioning and Reduction of Postoperative Morbidity in the Treatment of Gingival Recession Defects: A Randomized Controlled Clinical Trial.

Authors:  Tarek M Eltayeb; Rami M Ghali; Shahinaz G Elashiry; Fatma H Eldemerdash; Islam S Shaker; Ahmed Y Gamal; Georgios E Romanos
Journal:  Photobiomodul Photomed Laser Surg       Date:  2021-06-11

10.  Investigation of Coronal Leakage of Root Fillings after Smear Layer Removal with EDTA or Er,Cr:YSGG Laser through Capillary Flow Porometry.

Authors:  Tom Edgard Maria Vergauwen; Rafaël Michiels; Dries Torbeyns; Maarten Meire; Mieke De Bruyne; Roeland Jozef Gentil De Moor
Journal:  Int J Dent       Date:  2014-02-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.