Literature DB >> 3594746

Finite element analysis of myocardial diastolic function using three-dimensional echocardiographic reconstructions: application of a new method for study of acute ischemia in dogs.

D D McPherson, D J Skorton, S Kodiyalam, L Petree, M P Noel, R Kieso, R E Kerber, S M Collins, K B Chandran.   

Abstract

The effect of acute myocardial ischemia on the myocardial elastic modulus has been a matter of controversy. To evaluate this question, diastolic elastic modulus was assessed by finite element analysis of left ventricular geometry using three-dimensional echocardiographic reconstructions and right and left ventricular pressure recordings. Elastic properties were estimated before and after coronary occlusion in 6 open-chest dogs. Elastic modulus values were derived by means of a computer program that determined the global elastic modulus that best predicted the diastolic changes in left ventricular geometry. In the finite element analysis after coronary occlusion, two analyses were performed: one utilizing the control elastic modulus for all segments of the left ventricle and one in which ischemic (dyskinetic) segments were assigned a higher elastic modulus. Results showed that the control elastic modulus was a poor predictor of diastolic left ventricular expansion after coronary occlusion. The finite element analysis in which the ischemic segments were assigned a higher elastic modulus better predicted ischemic diastolic wall motion patterns. Error values (difference between predicted and actual left ventricular segmental diastolic motion) were: control, 1.9 +/- 0.3 mm (mean +/- SD), ischemia, 2.9 +/- 0.5 mm, and 2.2 +/- 0.4 mm using the stiffer elastic modulus for ischemic segments. Error values were significantly higher (p less than 0.05) under ischemic conditions when the control elastic modulus was uniformly applied compared with control and ischemia with dyskinetic segments assigned a higher elastic modulus. From these data, it is concluded that the myocardial diastolic elastic modulus is increased by ischemia and that this approach may allow clinical assessment of intrinsic muscle stiffness.

Entities:  

Mesh:

Year:  1987        PMID: 3594746     DOI: 10.1161/01.res.60.5.674

Source DB:  PubMed          Journal:  Circ Res        ISSN: 0009-7330            Impact factor:   17.367


  5 in total

1.  Regional stress in a noncircular cylinder.

Authors:  R F Janz; S Ozpetek; L E Ginzton; M M Laks
Journal:  Biophys J       Date:  1989-01       Impact factor: 4.033

2.  Application of finite-element analysis with optimisation to assess the in vivo non-linear myocardial material properties using echocardiographic imaging.

Authors:  G J Han; K B Chandran; N L Gotteiner; M J Vonesh; A W Joob; R Greene; G M Lanza; D D McPherson
Journal:  Med Biol Eng Comput       Date:  1993-09       Impact factor: 2.602

3.  Mathematical three-dimensional solid modeling of biventricular geometry.

Authors:  J S Pirolo; S J Bresina; L L Creswell; K W Myers; B A Szabó; M W VAnnier; M K Pasque
Journal:  Ann Biomed Eng       Date:  1993 May-Jun       Impact factor: 3.934

4.  Quantitative three dimensional echocardiography in patients with pulmonary hypertension and compressed left ventricles: comparison with cross sectional echocardiography and magnetic resonance imaging.

Authors:  H D Apfel; Z Shen; A S Gopal; V Vangi; D Solowiejczyk; K Altmann; R J Barst; L M Boxt; L D Allan; D L King
Journal:  Heart       Date:  1996-10       Impact factor: 5.994

5.  Left Ventricle Segmentation Using Model Fitting and Active Surfaces.

Authors:  Peter C Tay; Bing Li; Chris D Garson; Scott T Acton; John A Hossack
Journal:  J Signal Process Syst       Date:  2009-04-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.