Dedicated convolutional neural network for noise reduction in ultra-high-resolution photon-counting detector computed tomography.

Nathan R Huber1, Andrea Ferrero1, Kishore Rajendran1, Francis Baffour1, Katrina N Glazebrook1, Felix E Diehn1, Akitoshi Inoue1, Joel G Fletcher1, Lifeng Yu1, Shuai Leng1, Cynthia H McCollough1.   

Abstract

Objective.To develop a convolutional neural network (CNN) noise reduction technique for ultra-high-resolution photon-counting detector computed tomography (UHR-PCD-CT) that can be efficiently implemented using only clinically available reconstructed images. The developed technique was demonstrated for skeletal survey, lung screening, and head angiography (CTA).Approach. There were 39 participants enrolled in this study, each received a UHR-PCD and an energy integrating detector (EID) CT scan. The developed CNN noise reduction technique uses image-based noise insertion and UHR-PCD-CT images to train a U-Net via supervised learning. For each application, 13 patient scans were reconstructed using filtered back projection (FBP) and iterative reconstruction (IR) and allocated into training, validation, and testing datasets (9:1:3). The subtraction of FBP and IR images resulted in approximately noise-only images. The 5-slice average of IR produced a thick reference image. The CNN training input consisted of thick reference images with reinsertion of spatially decoupled noise-only images. The training target consisted of the corresponding thick reference images without noise insertion. Performance was evaluated based on difference images, line profiles, noise measurements, nonlinear perturbation assessment, and radiologist visual assessment. UHR-PCD-CT images were compared with EID images (clinical standard).Main results.Up to 89% noise reduction was achieved using the proposed CNN. Nonlinear perturbation assessment indicated reasonable retention of 1 mm radius and 1000 HU contrast signals (>80% for skeletal survey and head CTA, >50% for lung screening). A contour plot indicated reduced retention for small-radius and low contrast perturbations. Radiologists preferred CNN over IR for UHR-PCD-CT noise reduction. Additionally, UHR-PCD-CT with CNN was preferred over standard resolution EID-CT images.Significance.CT images reconstructed with very sharp kernels and/or thin sections suffer from increased image noise. Deep learning noise reduction can be used to offset noise level and increase utility of UHR-PCD-CT images.
© 2022 Institute of Physics and Engineering in Medicine.

Entities:  

Keywords:  convolutional neural network; deep learning; noise reduction; photon-counting detector CT

Mesh:

Year:  2022        PMID: 35944556      PMCID: PMC9444982          DOI: 10.1088/1361-6560/ac8866

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   4.174


  22 in total

Review 1.  Iterative reconstruction methods in X-ray CT.

Authors:  Marcel Beister; Daniel Kolditz; Willi A Kalender
Journal:  Phys Med       Date:  2012-02-10       Impact factor: 2.685

Review 2.  Vision 20/20: Single photon counting x-ray detectors in medical imaging.

Authors:  Katsuyuki Taguchi; Jan S Iwanczyk
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

3.  Development and validation of a practical lower-dose-simulation tool for optimizing computed tomography scan protocols.

Authors:  Lifeng Yu; Maria Shiung; Dayna Jondal; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2012 Jul-Aug       Impact factor: 1.826

4.  Clinical evaluation of a phantom-based deep convolutional neural network for whole-body-low-dose and ultra-low-dose CT skeletal surveys.

Authors:  Nathan Huber; Tara Anderson; Andrew Missert; Mark Adkins; Shuai Leng; Joel Fletcher; Cynthia McCollough; Lifeng Yu; Katrina N Glazebrook
Journal:  Skeletal Radiol       Date:  2021-06-10       Impact factor: 2.199

5.  Magician's Corner: 7. Using Convolutional Neural Networks to Reduce Noise in Medical Images.

Authors:  Nathan Robert Huber; Andrew D Missert; Bradley J Erickson
Journal:  Radiol Artif Intell       Date:  2020-09-30

6.  Diagnostic value of whole-body low-dose computed tomography (WBLDCT) in bone lesions detection in patients with multiple myeloma (MM).

Authors:  Davide Ippolito; Valeria Besostri; Pietro Andrea Bonaffini; Fausto Rossini; Alessandro Di Lelio; Sandro Sironi
Journal:  Eur J Radiol       Date:  2013-09-08       Impact factor: 3.528

7.  Initial clinical experience of a prototype ultra-high-resolution CT for assessment of small intracranial arteries.

Authors:  Hiroyuki Nagata; Kazuhiro Murayama; Shigetaka Suzuki; Ayumi Watanabe; Motoharu Hayakawa; Yasuo Saito; Kazuhiro Katada; Hiroshi Toyama
Journal:  Jpn J Radiol       Date:  2019-01-31       Impact factor: 2.374

8.  Comparison of image quality between spectral photon-counting CT and dual-layer CT for the evaluation of lung nodules: a phantom study.

Authors:  Salim A Si-Mohamed; Joel Greffier; Jade Miailhes; Sara Boccalini; Pierre-Antoine Rodesch; Aurélie Vuillod; Niels van der Werf; Djamel Dabli; Damien Racine; David Rotzinger; Fabio Becce; Yoad Yagil; Philippe Coulon; Alain Vlassenbroek; Loic Boussel; Jean-Paul Beregi; Philippe Douek
Journal:  Eur Radiol       Date:  2021-06-29       Impact factor: 5.315

9.  Ultra-high-resolution subtraction CT angiography in the follow-up of treated intracranial aneurysms.

Authors:  Frederick J A Meijer; Joanne D Schuijf; Joost de Vries; Hieronymus D Boogaarts; Willem-Jan van der Woude; Mathias Prokop
Journal:  Insights Imaging       Date:  2019-01-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.