NDIR CO2 gas sensors using a 10-cm-long gas channel and CMOS-compatible 12% doped ScAlN pyroelectric detector have previously demonstrated detection limits down to 25 ppm and fast response time of ∼2 s. Here, we increase the doping concentration of Sc to 20% in our ScAlN-based pyroelectric detector and miniaturize the gas channel by ∼65× volume with length reduction from 10 to 4 cm and diameter reduction from 5 to 1 mm. The CMOS-compatible 20% ScAlN-based pyroelectric detectors are fabricated over 8-in. wafers, allowing cost reduction leveraging on semiconductor manufacturing. Cross-sectional TEM images show the presence of abnormally oriented grains in the 20% ScAlN sensing layer in the pyroelectric detector stack. Optically, the absorption spectrum of the pyroelectric detector stack across the mid-infrared wavelength region shows ∼50% absorption at the CO2 absorption wavelength of 4.26 μm. The pyroelectric coefficient of these 20% ScAlN with abnormally oriented grains shows, in general, a higher value compared to that for 12% ScAlN. While keeping the temperature variation constant at 2 °C, we note that the pyroelectric coefficient seems to increase with background temperature. CO2 gas responses are measured for 20% ScAlN-based pyroelectric detectors in both 10-cm-long and 4-cm-long gas channels, respectively. The results show that for the miniaturized CO2 gas sensor, we are able to measure the gas response from 5000 ppm down to 100 ppm of CO2 gas concentration with CO2 gas response time of ∼5 s, sufficient for practical applications as the average outdoor CO2 level is ∼400 ppm. The selectivity of this miniaturized CO2 gas sensor is also tested by mixing CO2 with nitrogen and 49% sulfur hexafluoride, respectively. The results show high selectivity to CO2 with nitrogen and 49% sulfur hexafluoride each causing a minimum ∼0.39% and ∼0.36% signal voltage change, respectively. These results bring promise to compact and miniature low cost CO2 gas sensors based on pyroelectric detectors, which could possibly be integrated with consumer electronics for real-time air quality monitoring.
NDIR CO2 gas sensors using a 10-cm-long gas channel and CMOS-compatible 12% doped ScAlN pyroelectric detector have previously demonstrated detection limits down to 25 ppm and fast response time of ∼2 s. Here, we increase the doping concentration of Sc to 20% in our ScAlN-based pyroelectric detector and miniaturize the gas channel by ∼65× volume with length reduction from 10 to 4 cm and diameter reduction from 5 to 1 mm. The CMOS-compatible 20% ScAlN-based pyroelectric detectors are fabricated over 8-in. wafers, allowing cost reduction leveraging on semiconductor manufacturing. Cross-sectional TEM images show the presence of abnormally oriented grains in the 20% ScAlN sensing layer in the pyroelectric detector stack. Optically, the absorption spectrum of the pyroelectric detector stack across the mid-infrared wavelength region shows ∼50% absorption at the CO2 absorption wavelength of 4.26 μm. The pyroelectric coefficient of these 20% ScAlN with abnormally oriented grains shows, in general, a higher value compared to that for 12% ScAlN. While keeping the temperature variation constant at 2 °C, we note that the pyroelectric coefficient seems to increase with background temperature. CO2 gas responses are measured for 20% ScAlN-based pyroelectric detectors in both 10-cm-long and 4-cm-long gas channels, respectively. The results show that for the miniaturized CO2 gas sensor, we are able to measure the gas response from 5000 ppm down to 100 ppm of CO2 gas concentration with CO2 gas response time of ∼5 s, sufficient for practical applications as the average outdoor CO2 level is ∼400 ppm. The selectivity of this miniaturized CO2 gas sensor is also tested by mixing CO2 with nitrogen and 49% sulfur hexafluoride, respectively. The results show high selectivity to CO2 with nitrogen and 49% sulfur hexafluoride each causing a minimum ∼0.39% and ∼0.36% signal voltage change, respectively. These results bring promise to compact and miniature low cost CO2 gas sensors based on pyroelectric detectors, which could possibly be integrated with consumer electronics for real-time air quality monitoring.
Entities:
Keywords:
CMOS compatible; CO2 gas sensor; MEMS; abnormally oriented grains; nondispersive infrared; pyroelectric detector; scandium aluminum nitride (ScAlN)
Carbon dioxide (CO2) sensors have been of interest in recent years to monitor air quality
in enclosed crowded spaces. The need for well ventilated spaces is
especially important these days to ensure good air quality, so as
to reduce the transmission of SARS-CoV-2/COVID-19 (severe acute respiratory
syndrome coronavirus-2/coronavirus disease 2019). Even before the
COVID-19 pandemic, there were reports on the detrimental effects to
human health with extended exposure to high concentrations of CO2.[1] Specifically, elevated levels
of CO2 (>1000 ppm of CO2 gas concentration)
in enclosed spaces will result in sick building syndrome (SBS),[2] with occupants experiencing drowsiness, headaches,
and difficulties in concentrating. With the presence of CO2 sensors, one would be able to monitor in real-time the quality of
air, raising awareness on the quality of the air we breathe in. This
would become more of a reality if the CO2 gas sensors are
low cost and miniature. Cost is an important factor, as CO2 gas sensors which are low cost can enable more sensors to be deployed
for more accurate real-time CO2 level monitoring within
a certain area. If these sensors are high cost, the number of sensors
that can be deployed for air quality monitoring will be limited by
the sensor price. Other than the cost of manufacturing the sensor,
the operational cost such as the power required to operate the sensor
and the temperature at which the sensor operates could also add to
the cost. At the same time, functional flexibility of these CO2 sensors should also be considered, whether they can be modified
with minimum cost or involve change to sense different gases. In general,
there are many factors when considering the cost of a CO2 sensor. In addition to reducing its cost, the size of each sensor
is also of importance, as a bulky sensor will make mass deployment
difficult, not to mention that material cost might increase for a
sensor with a bigger form factor. Targeting low-cost and miniature
sensors will allow them to be easily integrated onto consumer electronics,
allowing one to monitor CO2 levels in real-time.Much effort has been put into the development of CO2 gas
sensors for environmental monitoring. Types of CO2 sensors
that have been reported include mid-infrared (mid-IR) sensors
based on the nondispersive infrared (NDIR)[3−6] technique, attenuated total reflection[7] technique, chemiresistive[8] sensors, amperometric[9] sensors, acoustic[10] sensors, and the adoption of metal–organic
framework[11−13] for improved gas sensing performance.NDIR
CO2 sensors are promising as they have been proven
to have high selectivity and high stability[14−16] with fast response
time.[17,18] However, they have also been reported to
have a large footprint[13] and are costly.[5] We try to overcome these limitations by reducing
the size of the gas channel of an NDIR CO2 sensor and using
a broadband thermal emitter and scandium aluminum nitride (ScAlN)-based
pyroelectric detector.Pyroelectric detectors are thermal sensors
that will produce an
electrical signal when they experience an instantaneous temperature
change. However, as pyroelectric materials are also piezoelectric,
pyroelectric detectors will be affected by microphonic effects.[19,20] Any mechanical stress encounter by the pyroelectric detector due
to vibration or pressure will also produce an electrical signal output.
In pyroelectric detectors, microphonic effects are undesirable, and
it is important to minimize them. If the signal due to microphonic
effects is too high, it can exceed the device signal for minimum thermal
detection and the detection limit of the pyroelectric detector will
be affected. To reduce microphonic effects, efforts have been made
to reduce mechanical vibrations in the pyroelectric detectors. InfraTec
GmbH, one of the major companies that develop and manufacture pyroelectric
detectors, recommends using vibration dampers such as rubber connectors
or elastic cables to minimize mechanical vibrations and to choose
suitable electrical bandpass to reduce interferences from higher frequencies.[21] Norkus et al.[20] consider
the device layout, mounting elements and introduce thermal isolation
trenches, while Xu et al.[22] use 3D-printing
of inverted pyramid suspending architecture for the pyroelectric detectors
to minimize the microphonic effect.Studies leveraging pyroelectric
effects include self-powered temperature
sensors,[23] solar energy harvesters,[24] and driving wireless sensors.[25] Here, we use a ScAlN-based pyroelectric detector for CO2 gas sensing. The thermal emitter and pyroelectric detector
emits and receives light, respectively, over a wide wavelength range,
hence allowing the flexibility to detect different types of gases
by requiring only the change in optical filter to match the characteristic
absorption wavelength of the gas targeted for detection. By using
a broadband thermal emitter and a pyroelectric detector, we try to
reduce the cost of our sensor by allowing it to have the flexibility
to be used to detect different gases with only the change of an optical
filter, rather than the source or the detector. The thermal emitter
and pyroelectric detector operate at room temperature; hence no extra
cost is required to create the stipulated temperature conditions.
In addition, our ScAlN-based pyroelectric detectors are complementary
metal oxide semiconductor (CMOS)-compatible.[26] The ScAlN layer is deposited at a low thermal budget of ∼200
°C, and the detector devices are fabricated using semiconductor
wafer level technology on 8-in. silicon (Si) wafers. This will allow
for mass manufacturing and miniaturization, with many detectors fabricated
on one 8-in. Si wafer, reducing the cost per detector, and allowing
for monolithic integration with CMOS electronics. If we consider a
detector with die size of 3 mm × 2 mm fabricated over an 8-in.
wafer area and 80% yield, we estimate ∼4000 detector devices
obtained from one wafer.In this paper, we build a low cost,
miniature NDIR CO2 gas sensor using a 20% Sc-doped AlN-based
pyroelectric detector
fabricated in-house with a 40-mm-long, 1-mm-diameter gas channel and
a broadband thermal emitter (Axetris, EMIRS50 AT06 V). This gas sensor
is reduced by ∼65 times in volume compared to its larger version
100-mm-long, 5-mm-diameter gas channel. We characterize the 20% doped
ScAlN-based pyroelectric detector. Top view scanning electron microscopy
(SEM) shows grainy detector surfaces, and cross-sectional transmission
electron microscopy (TEM) images reveal abnormally oriented grains
(AOGs) in the ScAlN sensing layer. This detector is further characterized
optically and electrically. The absorption of the pyroelectric detector
stack shows ∼50% absorption at the CO2 absorption
wavelength of 4.26 μm. The pyroelectric coefficient is calculated
to be ∼11.4 μC/m2 K when a temperature fluctuation
of 2 °C (from 24 to 26 °C) is applied within ∼8 s
to the pyroelectric detector using a Peltier heater. The pyroelectric
coefficient obtained is higher than that of 12% ScAlN previously reported.[27] We also note that as the set background temperature
increases, the output current measured from the pyroelectric detector
shows an increasing trend. This eventually corresponds to an increase
in the calculated pyroelectric coefficient when measured at higher
background temperature, ranging from ∼11.4 to ∼18.7
μC/m2 K. The CO2 gas sensing response
is measured for this miniature CO2 gas sensor together
with its larger version. For this miniature CO2 gas sensor,
the results show a lower detection limit ∼100 ppm of CO2 gas concentration and response time ∼5 s. With the
size of this current miniature gas sensor taken into account and
compared with NDIR CO2 gas sensors reported in recent years,
the performance of our miniature gas sensor using 20% ScAlN-based
pyroelectric detector is comparable, if not better. The selectivity
of this miniature CO2 gas sensor is also tested by mixing
CO2 with nitrogen (N2) and 49% sulfur hexafluoride
(SF6), respectively, instead of synthetic air. The results
show high selectivity to CO2 with N2 and SF6 causing a minimum signal voltage change of ∼0.39%
and ∼0.36%, respectively. Finally, we do a comparison of the
performance of our miniaturized CO2 gas sensor with off-the-shelf
CO2 gas sensors in terms of detection range, response time,
and interference from other gases. Overall, the gas sensing performance
of the miniature CO2 gas sensor obtained is encouraging
and signifies the possibility of miniaturizing the NDIR CO2 gas sensor, which could in time be integrated with consumer electronics.
Experimental Section
20% ScAlN-Based Pyroelectric Detector
The fabrication
of this 20% ScAlN-based pyroelectric detector follows similar steps[27−29] as what had previously been described for realization of 12% ScAlN-based
pyroelectric detectors. The top electrode is titanium nitride (TiN),
while the bottom electrode is molybdenum (Mo). The ScAlN sensing layer
is sandwiched between the top and bottom electrode. Here, the sensing
layer is 20% Sc-doped AlN, and this layer is deposited using the physical
vapor deposition process at a deposition temperature of ∼200
°C. Above the top TiN electrode is a dielectric absorber stack.
Aluminum (Al) is used for the metal contact layers for the top and
bottom electrodes. Beneath the bottom Mo electrode is a layer of silicon
dioxide (SiO2) patterned with waffle-like structures[27,30] to help increase mechanical stiffness of the pyroelectric detector
membrane stack and act as a damper to reduce microphonic effects.
Electrical Measurement of 20% ScAlN-Based Pyroelectric Detector
The 20% ScAlN-based pyroelectric detector with AOGs in the ScAlN
sensing layer is placed in a bathtub hybrid package housing wire-bonded
to 2 different leads. This bathtub hybrid package is then placed on
a Peltier heater using thermal grease. This heater is connected to
a benchtop temperature controller. The detector in the bathtub hybrid
package is connected to a current amplifier with gain set at 109 V/A. The current amplifier is connected to an oscilloscope
to capture the waveform generated when the temperature change is triggered.
The temperature controller is then set to the respective background
temperature. During measurement, the temperature controller is set
to trigger a 2 °C temperature change to the Peltier heater. The
Peltier then heats by 2 °C within ∼8 s. The pyroelectric
detector detects the temperature fluctuation and generates a pyroelectric
current waveform captured by the oscilloscope.
Gas Sensor Assembly
Figure a shows schematics of two CO2 gas
sensors. We use an NDIR gas sensing technique which usually consists
of a source, optical filter, gas channel, and detector system. A broadband
thermal emitter (Axetris, EMIRS50 AT06 V) with heater area ∼0.64
mm2, set to modulate at 17.4 Hz, is used in our case to
emit light across wavelengths from 2 to 14 μm. This is to reduce
cost where one emitter source could be used to detect any gases that
have characteristic absorption wavelength falling in the range 2–14
μm, hence increasing the functional flexibility of this sensor.
We only need to change the narrow bandpass optical filter that will
allow specific wavelength to pass through, which would correspond
to the absorption wavelength of the gas to be detected. In our case,
as we are detecting CO2, we choose an optical filter of
center wavelength ∼4.26 μm with half power bandwidth
∼180 nm. On the detector end is a 20% ScAlN-based pyroelectric
detector with AOGs. The sensing area of the detector is ∼0.29
mm2. A compound parabolic collector (CPC) could be used
to concentrate the optical signal collected onto the detector. Between
the source and the detector is a metal gas channel. Initially the
gas channel is of diameter ∼5 mm, length ∼100 mm, and
volume ∼1.96 cm3. To reduce the gas sensor size,
we further shrink the gas channel from diameter ∼5 mm down
to ∼1 mm with channel length shortened from ∼100 to
∼40 mm. Figure b shows the photo images of the reduced size gas sensor. The left
image shows the gas channel hole with diameter ∼1 mm where
the IR light will travel through. The right image presents the assembly
of the gas sensor. The effective region of the gas channel consists
of the 1-mm-diameter gas channel hole and the 40-mm-long gas channel
length. For this reduced size gas sensor, a bare die emitter without
reflector is used. As the heater area of the thermal emitter is a
square shape with dimensions 0.8 mm × 0.8 mm while the gas channel
is circular of diameter ∼1 mm, a small portion of radiation
from the heater at its 4 corners will be blocked from entering the
gas channel. To couple as much radiation emitted from the thermal
emitter into the small gas channel, we place the heater surface as
close as possible to the gas channel hole, with an optical filter
inserted in front of the gas channel hole to allow only radiation
of ∼4.26 μm wavelength to enter the gas channel. With
the IR rays that enter the gas channel limited to only ∼4.26
μm wavelength, this will help to reduce the unwanted increase
in temperature in the gas channel that might occur due to IR ray interaction
with the gas molecules in the small channel. The walls of the gas
channel are made of Al coated with a layer of gold which are good
thermal conductors and could also help to conduct away some of this
unwanted change in temperature in the inside of the gas channel. Meanwhile,
on the other end of the gas channel, the detector is placed as close
as possible to the gas channel hole to collect as much radiation flux
as possible coming out of the gas channel. Jigs are designed for placement
of the emitter and detector such that the center of the emitter’s
heater source and the detector’s sensing is positioned to face
the 1-mm-diameter gas channel hole on both ends, held together by
micromachined fixtures and screws. There are 2 holes on top of the
gas channel for gas inlet and outlet. The CO2 gas enters
through the gas inlet near the emitter end, travels through the gas
channel, and exits through the gas outlet near the detector end via
gas tubes of outer diameter 3.175 mm which are inserted into the inlet
and outlet holes. This gas channel can be cleaned by purging with
N2 gas or by isopropyl alcohol (C3H8O). The total volume of the gas channel is reduced by ∼65
times, from ∼1.96 cm3 to ∼0.03 cm3.
Figure 1
(a) Schematics showing the configuration of NDIR CO2 sensors
used (partially exploded view drawing). A thermal emitter
is used as the source, and 20% ScAlN pyroelectric detector with AOGs
is used as the detector. To miniaturize the system, the gas channel
is reduced from 100 mm length to 40 mm length, with diameter from
5 mm reduced to 1 mm, respectively. Optical filters are inserted along
the light path to allow light of wavelength ∼4.26 μm
to pass through, as 4.26 μm is the molecular characteristic
wavelength that CO2 absorbs. (b) Photo images showing the
reduced size gas channel with the left image revealing the gas channel
hole with diameter 1 mm where the IR light will travel through and
the right image presenting the assembly of the gas sensor. The effective
region of the gas channel is the 1-mm-diameter gas channel hole and
the 40-mm-long gas channel length. The thermal emitter source and
∼4.26 μm wavelength optical filter are on one end of
the gas channel, and the 20% ScAlN-based pyroelectric detector is
on the other end of the gas channel. The emitter and detector are
positioned with the center of the heater area and sensing area right
in front of the 1-mm-diameter gas channel, held together by micromachined
fixtures and screws. There are 2 holes on top of the gas channel for
the gas inlet and outlet.
(a) Schematics showing the configuration of NDIR CO2 sensors
used (partially exploded view drawing). A thermal emitter
is used as the source, and 20% ScAlN pyroelectric detector with AOGs
is used as the detector. To miniaturize the system, the gas channel
is reduced from 100 mm length to 40 mm length, with diameter from
5 mm reduced to 1 mm, respectively. Optical filters are inserted along
the light path to allow light of wavelength ∼4.26 μm
to pass through, as 4.26 μm is the molecular characteristic
wavelength that CO2 absorbs. (b) Photo images showing the
reduced size gas channel with the left image revealing the gas channel
hole with diameter 1 mm where the IR light will travel through and
the right image presenting the assembly of the gas sensor. The effective
region of the gas channel is the 1-mm-diameter gas channel hole and
the 40-mm-long gas channel length. The thermal emitter source and
∼4.26 μm wavelength optical filter are on one end of
the gas channel, and the 20% ScAlN-based pyroelectric detector is
on the other end of the gas channel. The emitter and detector are
positioned with the center of the heater area and sensing area right
in front of the 1-mm-diameter gas channel, held together by micromachined
fixtures and screws. There are 2 holes on top of the gas channel for
the gas inlet and outlet.
CO2 Gas Response Measurement
The CO2 gas sensor consists of the thermal emitter (Axetris, EMIRS50
AT06V), the optical filter, the gas channel, and the 20% ScAlN-based
pyroelectric detector with AOGs. The thermal emitter is set to generate
a square wave with peak-to-peak voltage of 2.6 V and duty cycle (50%)
at a frequency of 17.4 Hz. The pyroelectric detector is connected
to a current amplifier with gain set at 109 V/A, which
is connected to a lock-in amplifier to capture the gas response signal.
As the lock-in amplifier is set to read only signals modulated at
17.4 Hz frequency, it could help to further reduce an unwanted change
in temperature (which does not occur at a specific frequency) caused
by interaction between the IR rays and the gas molecules in the small
gas channel. The gas channel contains inlet and outlet holes for CO2 gas and synthetic air to pass through. The gas measurement
is done in a dry laboratory environment with the room temperature
at ∼22 °C.
Results and Discussion
20% ScAlN Pyroelectric Films with Abnormally Oriented Grains
Figure shows the
top-view SEM and cross-sectional TEM images of the 20% ScAlN-based
pyroelectric detector fabricated in-house for gas sensing. The top-view
SEM of the pyroelectric detector stack of area ∼500 μm
× 500 μm (Figure a) with the top electrode TiN line and bottom electrode Mo
line. They will be connected to Al metal contacts, which will subsequently
be wire-bonded and electrically connected to extract the electrical
signal from the detector. The pyroelectric detector area of ∼500
μm × 500 μm is the sensing area size. This area will
sense the incoming IR radiation flux and translate it to electrical
signal output from the detector. Figure b shows a zoom-in image of the top surface
of the detector stack. The SEM image shows a somewhat grainy rough
surface with grain diameters of around tens to hundreds nanometers.
This grainy rough surface could be accumulated roughness from the
subsequent film layers beneath. To examine the layers underneath the
top surface, cross-sectional TEM is used to image the detector stack.
Figure 2
Top view
SEM images of (a) the pyroelectric detector device. (b)
The top surface shows grainy rough morphology, likely caused by 20%
ScAlN with AOGs beneath. Cross sectional TEM images show (c) the different
layer stacks in the pyroelectric detector with ∼1-μm-thick
ScAlN pyroelectric sensing layer sandwiched between the Mo bottom
electrode and TiN top electrode. On top of the TiN top electrode is
an absorber stack of SiO2–SiN–SiO2. Instead of columnar structures aligned to the c-axis on the ScAlN layer, AOGs aligned away from the c-axis are observed as indicated by the red arrows. (d) Zoom-in into
the ScAlN layer show more obvious AOGs within ScAlN layer.
Top view
SEM images of (a) the pyroelectric detector device. (b)
The top surface shows grainy rough morphology, likely caused by 20%
ScAlN with AOGs beneath. Cross sectional TEM images show (c) the different
layer stacks in the pyroelectric detector with ∼1-μm-thick
ScAlN pyroelectric sensing layer sandwiched between the Mo bottom
electrode and TiN top electrode. On top of the TiN top electrode is
an absorber stack of SiO2–SiN–SiO2. Instead of columnar structures aligned to the c-axis on the ScAlN layer, AOGs aligned away from the c-axis are observed as indicated by the red arrows. (d) Zoom-in into
the ScAlN layer show more obvious AOGs within ScAlN layer.Figure c shows
its cross-sectional TEM image. We can see an ∼1-μm-thick
ScAlN layer sandwiched between the bottom Mo electrode (thickness
∼200 nm) and the top TiN electrode (thickness ∼50 nm).
On top of the TiN top electrode is the absorber stack that helps to
absorb more light that radiates onto the detector. This absorber stack
consists of 3 layers of dielectric: ∼500-nm-thick silicon dioxide
(SiO2), ∼300 nm silicon nitride (SiN), and ∼100-nm-thick
SiO2. In addition, we also observe AOGs[31−34] in the 20% ScAlN layer, as indicated
by the red arrows. We note that the interface between the ScAlN pyroelectric
layer and the TiN top electrode layer is not smooth. This roughness
comes from the ScAlN layer, caused by the AOGs that usually form as
the film thickness increases. The grains of the AOGs also grow bigger
with increasing film thickness, attributed to the grainy surface observed
at the top layer of the detector in Figure b and the rough interface between the ScAlN
pyroelectric layer and the TiN top electrode layer. In cases when
there are no AOGs, the ScAlN layers would have presented columnar
structures in the c-axis orientation. With AOGs,
some of the crystal structures are oriented away from the c-axis. Figure d shows a higher magnification TEM image of the ScAlN layer
where we observe the AOG boundaries (indicated by the red arrows)
clearly distinguished among the rest of the ScAlN film. A closer look
at the top surface of the ScAlN film shows “bumps” of
size ∼100–200 nm. These “bumps” from the
AOGs subsequently contribute to the rough surface of the detector
as seen in Figure b.As the doping concentration of Sc increases in AlN films,
the chances
of AOG formation increases. In fact, it has been noted that higher
Sc concentration usually results in increased density of AOGs in the
film.[35] AOGs usually nucleate midway during
the film growth, grow larger as the film thickness increases, and
occur in the upper part of the film. They are aligned away from the
film’s c-axis orientation and usually present
themselves as bigger grains, increasing the film’s surface
roughness, as noted from Figure .Figure shows the
optical and electrical characteristics of the 20% ScAlN pyroelectric
detector stack with AOGs. Figure a shows the Fourier Transform Infrared (FTIR) measured
reflection and transmission spectra of this detector stack across
wavelengths range 2–14 μm. The inset shows that when
light impinges on the pyroelectric detector stack, it will either
transmit through the stack, reflect from the stack, or be absorbed
by the stack. In Figure a, the transmission spectrum measured shows negligible (∼0%)
intensity which is probably caused by the ∼200-nm-thick Mo
bottom electrode layer toward the bottom of the detector stack that
blocks the light from transmitting. On the other hand, the reflection
spectrum shows high reflection in the ∼4 μm wavelength
region. This will subsequently affect the absorption intensity at
the same wavelength region, as absorption is calculated by subtracting
the measured FTIR transmission and reflection spectra across wavelengths
in the range 2–14 μm from 100%.[3,30,36]
Figure 3
(a) FTIR measurement spectra showing the reflection
and transmission
spectra of the 20% doped ScAlN pyroelectric detector stack. The transmission
spectrum is ∼0% (negligible) across the wavelength range of
2–14 μm due to the 200-nm-thick Mo bottom electrode present
in the detector stack. The reflection spectrum shows high reflection
at around a 4 μm wavelength. Inset shows a simple schematic
of how the FTIR light source impinges on the detector stack that results
in transmission, absorption, and reflection. (b) The FTIR absorption
spectrum of the 20% doped ScAlN pyroelectric detector stack. The results
show around 50% absorption at an ∼4.26 μm wavelength
which is the strongest CO2 characteristic absorption line
with negligible overlap with the absorption peaks from other gases
commonly present in ambient air. High absorption (≥85%) is
observed at the wavelength range ∼4.6–8 μm. (c)
The pyroelectric coefficient, ρ, of 20% ScAlN with AOGs calculated
from the measured pyroelectric signal output across the different
background temperatures, showing an increasing ρ as the temperature
increases with ρ ≈ 11.4–18.7 μC/m2 K. Inset shows a schematic on how the pyroelectric signal is extracted.
(a) FTIR measurement spectra showing the reflection
and transmission
spectra of the 20% doped ScAlN pyroelectric detector stack. The transmission
spectrum is ∼0% (negligible) across the wavelength range of
2–14 μm due to the 200-nm-thick Mo bottom electrode present
in the detector stack. The reflection spectrum shows high reflection
at around a 4 μm wavelength. Inset shows a simple schematic
of how the FTIR light source impinges on the detector stack that results
in transmission, absorption, and reflection. (b) The FTIR absorption
spectrum of the 20% doped ScAlN pyroelectric detector stack. The results
show around 50% absorption at an ∼4.26 μm wavelength
which is the strongest CO2 characteristic absorption line
with negligible overlap with the absorption peaks from other gases
commonly present in ambient air. High absorption (≥85%) is
observed at the wavelength range ∼4.6–8 μm. (c)
The pyroelectric coefficient, ρ, of 20% ScAlN with AOGs calculated
from the measured pyroelectric signal output across the different
background temperatures, showing an increasing ρ as the temperature
increases with ρ ≈ 11.4–18.7 μC/m2 K. Inset shows a schematic on how the pyroelectric signal is extracted.Figure b shows
an FTIR absorption spectrum of this detector stack. The drop in absorption
at around the 4 μm wavelength region is mostly due to the high
reflection of the detector stack in the same wavelength region as
depicted in Figure a. For our CO2 gas sensing application, we hope that absorption
will be as high as possible for the detector to receive as much optical
signal change due to slightest change in gas concentration, which
will subsequently increase the signal-to-noise ratio translated to
electrical signal output from the detector. In Figure b, the absorption is ∼50% at ∼4.26
μm wavelength. This is our wavelength region of interest where
the CO2 characteristic absorption line occurs. The absorption
of ∼50% for the 20% ScAlN-based pyroelectric detector with
AOGs is lower than that of the 12% ScAlN-based pyroelectric detector
previously reported with absorption ∼75%[3,29,36] but higher than that of AlN-based pyroelectric
detector which reports absorption ∼25%.[30,36] The high reflection at the ∼4 μm wavelength region
which causes lower absorption in the same wavelength region could
be caused by the rougher surface[37] of the
detector stack (as observed from Figure b previously) mainly attributed by the AOGs
in the 20% ScAlN layer that induces the rough interface between the
ScAlN layer and TiN (as observed from Figure c and d previously).Meanwhile, we
observe absorption ≥85% from the wavelength
range ∼4.6 to 8 μm. This is useful information when considering
detecting gases with characteristic absorption lines falling in this
wavelength range such as nitric oxide (NO), nitrogen dioxide (NO2), methane (CH4), and hydrogen sulfide (H2S).[38] However, it is also worthwhile to
take note that while we consider the detector’s absorption
across the mid-IR wavelength range, we should also take note of the
gas absorbance in this wavelength range, as different gases have difference
absorbance. According to the National Institute of Standards and Technology
(NIST) Chemistry WebBook (NIST Standard Reference Database Number
69), CO2 has an absorbance of ∼1.8[39] at the ∼4.26 μm wavelength, while NO has absorbance
of ∼0.63[40] at the ∼5.4 μm
wavelength, CH4 has absorbance of ∼0.36[41] at the ∼7.7 μm wavelength, and
H2S has absorbance of ∼0.18[42] at the ∼7.5 μm wavelength. Out of these 4 gases, CO2 has the highest absorbance, indicating that it absorbs more
IR radiation at the ∼4.26 μm wavelength compared to NO,
CH4, and H2S at their characteristic absorption
wavelengths, respectively. The absorbance of CO2 is ∼3×
that of NO and ∼10× that of H2S. Hence, even
though the detector’s absorption at the ∼4.26 μm
wavelength is ∼50% (Figure b), the high absorbance of CO2 gas allows
it to create enough of a drop in the radiation flux to be picked up
by the pyroelectric detector.In addition to the detector’s
absorption and gas absorbance,
the pyroelectric coefficient of the detector is also a factor that
determines the output signal received. In this work, we are using
>20% Sc-doped AlN compared to the previously reported[3] 12% Sc-doped AlN pyroelectric material. Our previous
work[27] has shown that the specific detectivity
of the
detector increases when doped with 12% Sc, and we anticipate a further
increase in specific detectivity as the Sc doping increases. Meanwhile,
Akiyama et al.[43] was examining the piezoelectric
response of ScAlN and noted an increase in the piezoelectric response
as the Sc doping concentration increases up to 43% Sc concentration.
The piezoelectric response starts to drop when the Sc concentration
increases beyond 43%. A similar trend for the pyroelectric response
in Sc-doped AlN might also occur.We further estimate the pyroelectric
coefficient (ρ) of this
20% ScAlN with AOGs based on the following equation:[27]where i is the current measured, A is the sensing area of the 20% ScAlN pyroelectric detector
stack with AOGs which is ∼0.29 mm2, dT is the temperature change, and dt is the rise time
of the detector when encountering the temperature change. Five readings
of current output were taken at each temperature variation of ∼24–26
°C to ∼84–86 °C. Figure c shows a plot of ρ calculated for
the 2 °C temperature change across different temperature settings.
The inset shows the schematic of how the pyroelectric output signal
is extracted. The pyroelectric coefficient of 20% ScAlN pyroelectric
detector with AOGs calculated ranges from ∼11.4 to ∼18.7
μC/m2 K, higher than what was previously reported
for the 12% ScAlN pyroelectric detector.[27,44] This is, in general, in line with the expectation that higher Sc
doping concentration gives higher pyroelectric coefficient, since
it has previously been demonstrated[43] that
the higher Sc doping concentration resulted in an increase in the
piezoelectric response of ScAlN.The pyroelectric coefficients
of AlN and Sc-doped AlN films reported
so far with different Sc doping concentrations compared with the pyroelectric
coefficient of our current 20% ScAlN are shown in Table S1. We note a general increase in the pyroelectric coefficient
as the Sc doping concentration increases up to 35%. For Sc doping
concentration above 35%, to the best of our knowledge, there has been
no report so far. When AlN is doped with Sc, Sc will replace Al to
form ScAlN. With more Sc substituting Al to form ScAlN, the increased
Sc–N bonds cause the original AlN wurzite crystal lattice to
soften its elastic constant and increase in piezoelectric stress coefficient,
leading to an increase in piezoelectric strain. Structurally, a decrease
in the c/a ratio of wurtzite structure
toward the c/a ratio of hexagonal
boron-nitride has been observed[45] as the
Sc concentration increases.If we consider the following equation[44,46] on effective pyroelectric coefficient (ρeff)where ρprim = primary pyroelectric
effect, e = piezoelectric
stress coefficients in Voigt notation, α and α = anisotropic linear
thermal expansion, d31 = transversal piezoelectric
strain coefficient, s11 and s12 = elastic compliance coefficient of ScAlN, and α = linear thermal expansion of substrate;
the increase in Sc substitution of Al will result in softening of
elastic constants leading to a reduction in s11 and s12, increase in piezoelectric
stress coefficients (e31 and e33), and piezoelectric strain (d31). The terms (2e31α + e33α) and will then increase, leading to increase
in effective pyroelectric coefficient.Although in general pyroelectric
coefficients of ScAlN increases
with increasing Sc doping concentration, this value might vary across
films prepared by different deposition methods due to film and substrate
properties, and impurity levels in the films.[44] The pyroelectric coefficient of our 20% ScAlN pyroelectric detectors
show ∼11.4 μC/m2 K at room temperature, slightly
higher than those reported in the literature of ∼20% Sc-doped
AlN.[44,47] Kurz et al.[44] reported a pyroelectric coefficient of ∼8 μC/m2 K at room temperature for 22% Sc-doped AlN and Bette et al.[47] reported pyroelectric coefficient ∼9.7
μC/m2 K for 27% Sc-doped AlN.We believe that
our higher pyroelectric coefficient for 20% Sc-doped
AlN at room temperature could be due to the larger grains in the films
caused by the AOGs, as it has been previously demonstrated[48] that pyroelectric coefficient changes with variation
in average grain size, with increasing grain size exhibiting an increasing
pyroelectric coefficient.[49] In addition
to the higher pyroelectric coefficient of our 20% ScAlN pyroelectric
detectors measured at room temperature, we also note that its pyroelectric
coefficient seems to have temperature dependence characteristics,
showing an increasing trend across different background temperatures.
This is most likely also caused by the presence of AOGs in the 20%
ScAlN film. The larger grains from the AOGs result in the pyroelectric
coefficients being temperature dependence.[48] On top of that, factors such as impurities in the films[50] and stress and strain[51] induced in the films could also contribute to the temperature dependence
characteristics of pyroelectric coefficients. The observation of a
higher pyroelectric coefficient for 20% Sc-doped AlN with AOGs at
room temperature and its temperature dependence pyroelectric coefficient
characteristics in this work will provide a reference to help us understand
more on the pyroelectric characteristics of ScAlN films with AOGs
which remains relatively unexplored.
NDIR CO2 Gas Response
Figure shows the gas responses of the gas sensors
to CO2 gas at different gas concentrations. The gases are
cycled between synthetic air and CO2 gas at 2 min intervals. Figure a shows the CO2 gas responses for the miniaturized gas channel of volume
∼0.03 cm3, while Figure b shows that for the larger gas channel of
volume ∼1.96 cm3. For the smaller gas channel, the
gas sensor shows responses from 5000 ppm down to 100 ppm (Figure a), with CO2 gas response ranging from ∼0.3% to ∼9.4%. This is
in general sufficient for practical air quality monitoring. For the
bigger gas channel, the gas sensor shows responses from 5000 ppm down
to 50 ppm (Figure b), with CO2 gas response ranging from ∼2.3% to
∼40%. Though the data here only show measurements down to 50
ppm for the bigger gas channel sensor, it should be able to sense
lower than 50 ppm of CO2 concentration. The global average
atmospheric CO2 levels have been seeing an increasing trend,
from ∼390 ppm in Year 2010 to 412.5 ppm[52] reported in Year 2020. Indoors, when the CO2 gas concentration increases to ∼1000 ppm and higher, SBS
also kicks in where occupants will experience respiratory issues,
dizziness, drowsiness, and headaches with degraded performances in
problem solving and decision making.[53]
Figure 4
Voltage
readings due to different CO2 gas concentrations
between synthetic air and CO2 gas cycled at 2 min intervals
for (a) gas channel 40 mm length, 1 mm diameter, ∼0.03 cm3 volume from 5000 ppm of CO2 gas concentration
down to 100 ppm of CO2 gas concentration; and (b) gas channel
100 mm length, 5 mm diameter, ∼ 1.96 cm3 volume
from 5000 ppm of CO2 gas concentration down to 50 ppm of
CO2 gas concentration.
Voltage
readings due to different CO2 gas concentrations
between synthetic air and CO2 gas cycled at 2 min intervals
for (a) gas channel 40 mm length, 1 mm diameter, ∼0.03 cm3 volume from 5000 ppm of CO2 gas concentration
down to 100 ppm of CO2 gas concentration; and (b) gas channel
100 mm length, 5 mm diameter, ∼ 1.96 cm3 volume
from 5000 ppm of CO2 gas concentration down to 50 ppm of
CO2 gas concentration.We calculate the ratio of CO2 gas response
(voltage
change due to CO2 shown in Figure ) to synthetic air and plot it against respective
CO2 gas concentrations as shown in Figure . Figure a shows the experimental CO2 gas response
plotted against different CO2 gas concentrations for the
small ∼0.03 cm3 volume gas channel, while Figure b shows that for
the bigger ∼1.96 cm3 volume gas channel. We note
that across different CO2 gas concentrations, the CO2 gas response measured for the smaller gas channel is lower
than that of the bigger gas channel. Five readings of CO2 gas response are taken, and the average and data range are calculated
at each gas concentration.
Figure 5
CO2 gas response for (a) gas channel
volume ∼0.03
cm3 and (b) gas channel volume ∼1.96 cm3 across different CO2 gas concentrations up to 5000 ppm.
Modified Beer–Lambert equation is used to fit the experimental
data.
CO2 gas response for (a) gas channel
volume ∼0.03
cm3 and (b) gas channel volume ∼1.96 cm3 across different CO2 gas concentrations up to 5000 ppm.
Modified Beer–Lambert equation is used to fit the experimental
data.We try to fit the experimental data using the modified
Beer–Lambert’s
equation:[5,54]where x is the CO2 gas concentration, κ is the effective absorption coefficient
of CO2, l is the optical path length in
the gas system, which is ∼0.04 m for the small gas channel
and ∼0.1 m for the bigger gas channel, and “span”
is a coefficient which is an indication on the amount of IR radiation
that can be absorbed. The experimental data fitted well with the equation,
with coefficient of determination (R2)
of both gas channels >0.99 (∼0.9925 for the small gas channel
and ∼0.9976 for the big gas channel).With the fitted
data, we try to compare the various parameters
between the ∼0.03 cm3 volume and the ∼1.96
cm3 volume gas channels. The comparison of the fitted data
using eq for both gas
channels with ∼0.03 cm3 volume and ∼1.96
cm3 volume is shown in Table S2. The optical path lengths, l, used are based on
the gas channel lengths with 0.04 m for the smaller gas sensor and
0.1 m for the bigger gas sensor. “Span” differs between
gas channels, and due to the smaller volume of the ∼0.03 cm3 gas sensor, less IR radiation is able to pass through it,
hence less CO2 absorption, resulting in lower span compared
to the ∼1.96 cm3 gas sensor. The amount of IR radiation
that can be absorbed in the small gas sensor is less than the big
gas sensor which has greater volume, and hence will saturate faster
than the bigger gas sensor. Nevertheless, the effective absorption
coefficient of the smaller gas sensor is higher (∼0.00573 m–1) compared to that of the bigger gas sensor (∼0.00391
m–1), indicating more CO2 absorption
per unit m in the smaller gas sensor.Figure shows the
time taken for the gas sensors to detect 5000 ppm of CO2. We take the response time as t90, which
is the time taken for the gas sensor to detect a 90% change in the
gas concentration. The response time, t90, is ∼4.7 s for the smaller gas sensor (∼0.03 cm3 volume) and ∼1.3 s for the bigger gas sensor (∼1.96
cm3 volume). Although it takes around ∼3 s slower
for the smaller gas sensor to detect the change in the gas concentration,
the overall response times for both gas channels are around 5 s or
less. This response time is considered fast for a gas sensor working
at room temperature ∼22 °C environment, as most gas sensors
operating at room temperature have longer response time.[6,9,55]
Figure 6
Response times, t90, taken for gas
sensor to detect CO2 gas from the initial state of synthetic
air. Measurement is taken at 5000 ppm of CO2 gas concentration
for (a) ∼0.03 cm3 gas channel volume which gives t90 ∼ 4.7 s and (b) ∼1.96 cm3 gas channel volume which gives t90∼ 1.3 s.
Response times, t90, taken for gas
sensor to detect CO2 gas from the initial state of synthetic
air. Measurement is taken at 5000 ppm of CO2 gas concentration
for (a) ∼0.03 cm3 gas channel volume which gives t90 ∼ 4.7 s and (b) ∼1.96 cm3 gas channel volume which gives t90∼ 1.3 s.With the smaller gas sensor which is 65× smaller
in volume
compared to the bigger gas sensor, we manage to obtain the lowest
detection limit of 100 ppm of CO2 gas concentration and t90 ∼ 4.7 s, suitable for environmental
monitoring. To the best of our knowledge, this is the first demonstration
of a functional small NDIR CO2 gas sensor using a 20% ScAlN-based
pyroelectric detector. Table shows a comparison of the size and performance of recently
reported NDIR CO2 gas sensors using broadband sources and
microelectromechanical systems (MEMS) detectors for environmental
monitoring, published within the past 2 years.[3,5,6,56−58] For NDIR gas sensors which are known for their large footprints,
size reduction could bring about a compromise in the lowest detection
limit and response time. This can be seen in Table by an NDIR gas sensor[5] with lowest CO2 detection limit reported at
2 ppm. This sensor is however of larger footprint with length 448
mm and diameter ∼72 mm. Compared with other recently reported
NDIR CO2 gas sensors using broadband sources and MEMS detectors,
and with its size taken into account, the detection limit and response
time of our smaller gas sensor are comparable, if not better.
Table 1
Summary of Size and Performance of
Recently Reported NDIR CO2 Gas Sensors Using Broadband
Sources and MEMS Detectors for Environmental Monitoring, Including
Our Current Work
Source
Detector
Lowest measured
CO2 concentration (ppm)
Response
time (s)
Gas channel
diameter (mm)
Distance
between source and detector (mm)
Year of Reference
Filament Lamp
Thermopile
400
60
26
30–40
2021,[6] 2020[56]
MEMS IR emitter
Thermopile
0.5%
10
∼3
∼10
2021[57]
IR Light
LiTaO3 Pyroelectric
2
Information not
available
∼72
448
2020[5]
Broadband light
LiTaO3 Pyroelectric
Measured Range: 0–20%
<11
8
108
2022[58]
Thermal Emitter
12% ScAlN Pyroelectric
25
<2
5
100
2021[3]
Thermal Emitter
20% ScAlN Pyroelectric (with
AOGs)
100
∼5
1
40
Current work
We also check the smaller gas sensor’s selectivity
to gases
other than CO2. In our testing measurement, CO2 is mixed with synthetic air. Here, we replace synthetic air with
N2 and 49% SF6, respectively, to determine the
gas sensor’s response when CO2 is mixed with other
gases.Figure shows the
voltage detected when CO2 gas concentration of 2500 ppm
is mixed with synthetic air, N2, and 49% SF6 gas, respectively. The vertical axis is normalized to 2500 ppm of
CO2 gas in synthetic air. We note that the selectivity
of CO2 to N2 and SF6 seems high,
with the voltage readings approximately the same for 2500 ppm of CO2 in synthetic air, 2500 ppm of CO2 in N2, and 2500 ppm of CO2 in 49% SF6. Nevertheless,
there seems to be some slight deviation in voltage readings when CO2 is in N2 and in SF6 compared to CO2 in synthetic air.
Figure 7
Normalized voltage measured using the smaller
gas sensor (∼0.03
cm3 channel volume) when 2500 ppm of CO2 gas
is in synthetic air (blue plot), mixed with N2 gas (cyan
plot) and mixed with 49% SF6 gas (magenta plot), respectively.
The voltage readings are normalized to that of 2500 ppm of CO2 in synthetic air. Inset shows the percentage change in the
voltage when 2500 ppm of CO2 is mixed with N2 and 49% SF6, respectively, compared to 2500 ppm of CO2 in synthetic air.
Normalized voltage measured using the smaller
gas sensor (∼0.03
cm3 channel volume) when 2500 ppm of CO2 gas
is in synthetic air (blue plot), mixed with N2 gas (cyan
plot) and mixed with 49% SF6 gas (magenta plot), respectively.
The voltage readings are normalized to that of 2500 ppm of CO2 in synthetic air. Inset shows the percentage change in the
voltage when 2500 ppm of CO2 is mixed with N2 and 49% SF6, respectively, compared to 2500 ppm of CO2 in synthetic air.We further calculate the percentage change in voltage
when CO2 is in N2 and CO2 is in SF6 compared to CO2 in synthetic air. As shown by
the inset
in Figure , we calculate
a voltage change of ∼0.39% when CO2 is mixed with
N2 and a voltage change of ∼0.36% when CO2 is mixed with 49% SF6. The percentage of voltage changes
influenced by N2 and 49% SF6 is minimum or negligible.
This is most probably due to the optical filter that allows light
of ∼4.26 μm wavelength to pass through, which is the
wavelength at which CO2 gas absorbs, with mostly CO2 absorption peaks and negligible absorption peaks from other
gases.[59]Finally, we did a comparison
of our miniaturized CO2 gas sensor with commercial off-the-shelf
CO2 gas sensors
targeted for environmental monitoring applications. Table shows 6 off-the-shelf CO2 gas sensors based on different detection principles in addition
to our miniaturized CO2 gas sensor. The off-the-shelf CO2 gas sensors are based on photoacoustic spectroscopy (PAS),
metal oxide, and NDIR principles. The upper limit of their measurement
ranges can go until 2000 ppm or as high as 65000 ppm, while the lower
limit of their measurement ranges start from 0 or 400 ppm. As CO2 levels in ambient are at around 400 ppm, some CO2 gas sensors range start at 400 ppm. Response time of the sensors
are typically tens of seconds with 1 metal oxide CO2 gas
sensor having a response time of ∼1 s. As for interference
due to other gases, this information is not available for most off-the-shelf
CO2 gas sensors. We note that metal oxide CO2 gas sensors did mention interference from other gases which might
cause poisoning to the sensor sensing layer or that baselining is
required to mitigate the interference from other gases. Comparing
our NDIR miniaturized CO2 gas sensor with these off-the-shelf
CO2 gas sensors, we find our measurement range to be 100–5000
ppm. The lower detection limit is less than 400 ppm, which is the
CO2 concentration in the environment. We would also like
to highlight that our miniaturized CO2 gas sensor is capable
of sensing beyond 5000 ppm, but in this paper, measurement was done
up until 5000 ppm. For response time (t90), our miniaturized CO2 gas sensor is ∼5 s, which
is lower than most of the off-the-shelf CO2 gas sensors
presented in Table . As for interference caused by other gases, although this information
is not readily available for most of the off-the-shelf CO2 gas sensors, our miniaturized CO2 gas sensor has shown
(in Figure ) negligible
interference caused by N2 and SF6.
Table 2
Comparison of Our Miniaturized CO2 Gas Sensor with Commercial off-the-Shelf CO2 Gas
Sensors
Sensor Brand
Principle
Range (ppm)
Response
Time (s)
Interference
from other gases
Infineon (XENSIV PAS CO2[60])
PAS
0–32000
t63 ∼ 90
Information not available
Sensirion (SCD42[61])
PAS
0–40000
t63 ∼ 60
Information not available
SGX Sensortech (MiCS-VZ-89TE[62])
Metal Oxide
400–2000
Equivalent to conventional
NDIR CO2 sensors
Yes (some gases will cause
poisoning)
ScioSense (ENS160[63])
Metal Oxide
400–65000
t63 ∼ 1
Yes (requires baselining)
Alphasense (IRC-A1[64])
NDIR
0–5000
t90 < 40
Information not available
GSS (CozIR-A[65])
NDIR
0–2000, 0–5000, 0–10000
t90 ∼ 30
Information not available
Current work
NDIR
100–5000
t90 ∼ 5
Negligible
to N2, SF6 (Refer to Figure 7)
Conclusions
We have successfully downsized an NDIR
CO2 gas sensor
∼65 times from ∼1.96 cm3 volume down to ∼0.03
cm3 volume. A pyroelectric detector which contains 20%
ScAlN with AOGs is used as the detecting device. The pyroelectric
detector containing the 20% ScAlN sensing layer with AOGs is characterized
optically and electrically. The absorption of the pyroelectric detector
stack shows ∼50% at 4.26 μm wavelength which is the CO2 characteristic absorption wavelength. For 20% Sc-doped AlN
with AOGs, the pyroelectric coefficient calculated from the measured
output electrical signal shows a higher pyroelectric coefficient of
∼11.4 μC/m2 K. While deriving the pyroelectric
coefficient of 20% ScAlN with AOGs, we observe an increasing trend
in pyroelectric coefficient, as the background temperature increases
while we keep the temperature fluctuation at 2 °C. This could
most probably be due to AOGs in the ScAlN layer. The larger grains
from the AOGs could be one of the factors contributing to the temperature
dependence characteristics of 20% ScAlN in this work. The gas responses
of both the big and small gas sensors are measured at different levels
of CO2 gas concentrations. Both are able to reach gas concentrations
down to 100 ppm, a concentration suitable for practical monitoring
of CO2 levels in the environment. The experimental CO2 gas response data are fitted using modified Beer–Lambert’s
equation, and a comparison is done between both gas sensors. We note
that although the smaller gas sensor has smaller volume, which restricts
the amount of IR radiation that can travel in the gas channel, reducing
the amount of CO2 gas to be absorbed, the effective absorption
coefficient of the small gas sensor is higher compared to the big
gas sensor. The gas response times measured show that the smaller
gas sensor has a response time ∼4.7 s, which is ∼3 s
behind that of the bigger gas sensor which measures a response time
of ∼1.3 s. Nevertheless, overall response time for both gas
sensors fall in the range of ∼5 s or less, which is considered
fast in an operational environment of ∼22 °C, as most
gas sensors have a response time ranging from several minutes to hours.
A comparison is done between this smaller gas sensor and recently
published NDIR CO2 gas sensors using MEMS emitters and
detectors. With the smaller footprint of this gas sensor, its lower
detection limit and response time are comparable, if not better than
the rest being compared. This smaller gas sensor is further tested
in CO2 mixed with N2 and SF6, respectively,
to check the selectivity of this gas sensor to CO2. We
noted high selectivity with CO2 based on using N2 and SF6 with a voltage variation at ∼0.4% compared
to CO2 mixed in synthetic air. In addition to exploring
the pyroelectric characteristics of 20% doped ScAlN with AOGs, this
paper also demonstrates an NDIR CO2 gas sensor device downsized
in volume by ∼65 times, targeting the miniature CO2 gas sensor that could one day be integrated onto mobile phones or
consumer products for convenient real-time air quality monitoring,
which is especially of importance in these times of COVID-19.