Matthew A Muller1, James Hodovan1, Koya Ozawa1, Matthew W Hagen1, Theodore R Hobbs2, John Templon2, Yan Zhao1, John A Kaufman3, Jonathan R Lindner4.
Abstract
Ultrasound (US) generated by catheters used clinically for US-facilitated thrombolysis can release shear-dependent vasodilators from endothelial and red blood cells. We hypothesized that catheter-based US in the pulmonary artery (PA) decreases downstream vascular resistance and increases pulmonary blood flow. In rhesus macaques, a U.S. Food and Drug Administration-approved multi-element US catheter was placed in a pulmonary artery. Comprehensive echocardiography was performed (i) at baseline, (ii) during hypoxemia (12% FIO2) to increase pulmonary vascular resistance (PVR) and (c) 15 min after initiating US during hypoxemia. Reduced FIO2 produced intended reductions in oxygen saturation (69 ± 3%) and PaO2 (34 ± 5 mm Hg), yet on echocardiography, hypoxemia did not create the intended model, with only modest hypoxia-related increases in PA systolic pressure (24 ± 4 to 28 ± 4 mm Hg, p = 0.05) and no significant change in PVR or multiparametric right ventricular (RV) function. Although US did not further change total PVR, on 99mTc-macroalbumin aggregate single-photon-emission computed tomography imaging, lung perfusion was significantly higher in the lung ipsilateral to the US catheter versus the contralateral control lung (133 ± 48 cpm vs. 103 ± 43 × 103 cpm, p = 0.01). We conclude that PA catheter-based US increases regional lung perfusion, most likely from vasodilators that are conducted downstream.Entities:
Keywords: Pulmonary blood flow; Pulmonary embolism; Therapeutic ultrasound; Vasodilation
Mesh:
Substances:
Year: 2022 PMID: 35934554 PMCID: PMC9427700 DOI: 10.1016/j.ultrasmedbio.2022.06.012
Source DB: PubMed Journal: Ultrasound Med Biol ISSN: 0301-5629 Impact factor: 3.694