Ethylene oxide in dialyzer rinsing fluid: effect of rinsing technique, dialyzer storage time, and potting compound.

W Ansorge, M Pelger, W Dietrich, U Baurmeister.   

Abstract

Ethylene oxide (ETO) is recognized as one of the main causes of dialyzer-associated hypersensitivity reactions. We studied the amount of ETO in the rinsing fluid of ETO-sterilized hollow-fiber dialyzers as a function of rinsing technique, dialyzer storage time, and the amount of potting compound (known to be an ETO reservoir) in the dialyzer. The results suggested that the initial 500 ml of rinsing fluid removes much of the residual ETO in the dialyzer. Ethylene oxide extraction was enhanced substantially by rinsing at 37 degrees C versus 5 degrees C. However, considerable amounts of ETO remained in the dialyzer after an initial 500 ml rinse, some of which could be removed by rinsing with an additional 1,500 ml. High concentrations of ETO were measured in fluid that had been recirculated through the dialyzer for 10 min or longer and in fluid that had been allowed to remain in the dialyzer for 10 min under zero-flow conditions. The amount of ETO in the rinsing fluid decreased markedly as the dialyzer storage time was increased from 4 to 8 weeks and in dialyzers in which a portion of the potting compound had been replaced with a polycarbonate ring. Our results suggest that the dose of ETO administered to the patient at the outset of dialysis can be minimized by rinsing the dialyzer with 2 L of fluid at 37 degrees C and by avoiding administration of rinsing fluid that has been allowed to remain in contact with the dialyzer for more than several minutes. Use of a long storage interval and use of dialyzers containing reduced amounts of potting material will also reduce the ETO load.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3593041     DOI: 10.1111/j.1525-1594.1987.tb02641.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  5 in total

1.  Surgery in a patient allergic to ethylene oxide.

Authors:  Vanessa Demontoux; Emilie Moreau; Isabelle Peyron; Valérie Talon; Nejib Khouri; Jean-Paul Morin; Yvonnick Bézie
Journal:  Pharm World Sci       Date:  2007-09-21

Review 2.  Allergy to formaldehyde and ethylene-oxide.

Authors:  J Bousquet; F B Michel
Journal:  Clin Rev Allergy       Date:  1991 Fall-Winter

Review 3.  Diagnosis, Treatment, and Prevention of Hemodialysis Emergencies.

Authors:  Manish Saha; Michael Allon
Journal:  Clin J Am Soc Nephrol       Date:  2016-11-09       Impact factor: 8.237

4.  Recurrent anaphylaxis during cardiac catheterization due to ethylene oxide.

Authors:  Ahmad Hamad; Onyinye I Iweala; Cory Henderson; Shivanshu Madan; George A Stouffer; Scott P Commins; Edwin H Kim
Journal:  J Allergy Clin Immunol Pract       Date:  2018-04-30

5.  A porcine model of hemodialyzer reactions: roles of complement activation and rinsing back of extracorporeal blood.

Authors:  Ákos Pethő; Dorothea Piecha; Tamás Mészáros; Rudolf Urbanics; Christoph Moore; Bernard Canaud; László Rosivall; Tom Eirik Mollnes; Sonja Steppan; Gábor Szénási; János Szebeni; László Dézsi
Journal:  Ren Fail       Date:  2021-12       Impact factor: 2.606

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.