Sera from 138 patients who had experienced hypersensitivity-type reactions while on hemodialysis (reactors) were examined retrospectively by the radioallergosorbent test (RAST) for specific IgE antibody to ethylene oxide (ETO). Seventy-eight hemodialysis patients without a history of reaction were also evaluated as controls. Elevated serum RAST values (greater than 2.0) were more common in reactors (63%) than in controls (11%, p less than 0.001). In a second study, RAST assays were performed using human serum albumin conjugated to ETO (HSA-ETO) as antigen and also using a concentrate of fluid used to rinse ETO-sterilized dialyzers ("dialyzer extract") as antigen. The RAST ratios obtained with HSA-ETO were similar to those obtained using the dialyzer extract (rank order correlation coefficient = 0.829, p less than 0.001). In a third study, RAST inhibition was demonstrated both by HSA-ETO and dialyzer extract. Our results, extending previously published reports, suggest that hypersensitivity to ETO might play an important role in hemodialysis-associated hypersensitivity-type reactions.Entities: