Literature DB >> 35921020

Pilot tone-based prospective correction of respiratory motion for free-breathing myocardial T1 mapping.

Juliane Ludwig1, Kirsten Miriam Kerkering2, Peter Speier3, Tobias Schaeffter4, Christoph Kolbitsch2.   

Abstract

OBJECTIVE: To provide respiratory motion correction for free-breathing myocardial T1 mapping using a pilot tone (PT) and a continuous golden-angle radial acquisition.
MATERIALS AND METHODS: During a 45 s prescan the PT is acquired together with a dynamic sagittal image covering multiple respiratory cycles. From these images, the respiratory heart motion in head-feet and anterior-posterior direction is estimated and two linear models are derived between the PT and heart motion. In the following scan through-plane motion is corrected prospectively with slice tracking based on the PT. In-plane motion is corrected for retrospectively. Our method was evaluated on a motion phantom and 11 healthy subjects.
RESULTS: Non-motion corrected measurements using a moving phantom showed T1 errors of 14 ± 4% (p < 0.05) compared to a reference measurement. The proposed motion correction approach reduced this error to 3 ± 4% (p < 0.05). In vivo the respiratory motion led to an overestimation of T1 values by 26 ± 31% compared to breathhold T1 maps, which was successfully corrected to an average difference of 3 ± 2% (p < 0.05) between our free-breathing approach and breathhold data. DISCUSSION: Our proposed PT-based motion correction approach allows for T1 mapping during free-breathing with the same accuracy as a corresponding breathhold T1 mapping scan.
© 2022. The Author(s).

Entities:  

Keywords:  Cardiovascular MR; Pilot tone; Prospective respiratory motion correction; T1 mapping

Year:  2022        PMID: 35921020     DOI: 10.1007/s10334-022-01032-4

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.533


  31 in total

1.  Magnetic field threshold for accurate electrocardiography in the MRI environment.

Authors:  Mihaela Jekic; Yu Ding; Roger Dzwonczyk; Patrick Burns; Subha V Raman; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2010-12       Impact factor: 4.668

2.  Phase-sensitive inversion recovery for myocardial T1 mapping with motion correction and parametric fitting.

Authors:  Hui Xue; Andreas Greiser; Sven Zuehlsdorff; Marie-Pierre Jolly; Jens Guehring; Andrew E Arai; Peter Kellman
Journal:  Magn Reson Med       Date:  2012-06-26       Impact factor: 4.668

Review 3.  Cardiac T(1) imaging.

Authors:  Michael Jerosch-Herold; Raymond Y Kwong
Journal:  Top Magn Reson Imaging       Date:  2014-02

4.  Motion correction for myocardial T1 mapping using image registration with synthetic image estimation.

Authors:  Hui Xue; Saurabh Shah; Andreas Greiser; Christoph Guetter; Arne Littmann; Marie-Pierre Jolly; Andrew E Arai; Sven Zuehlsdorff; Jens Guehring; Peter Kellman
Journal:  Magn Reson Med       Date:  2011-08-29       Impact factor: 4.668

5.  Magnetic resonance imaging in patients with cardiomyopathies: when and why.

Authors:  J Schulz-Menger; M G Friedrich
Journal:  Herz       Date:  2000-06       Impact factor: 1.443

Review 6.  Assessment of myocardial fibrosis with cardiovascular magnetic resonance.

Authors:  Nathan Mewton; Chia Ying Liu; Pierre Croisille; David Bluemke; João A C Lima
Journal:  J Am Coll Cardiol       Date:  2011-02-22       Impact factor: 24.094

7.  Free-breathing, non-ECG, continuous myocardial T1 mapping with cardiovascular magnetic resonance multitasking.

Authors:  Jaime L Shaw; Qi Yang; Zhengwei Zhou; Zixin Deng; Christopher Nguyen; Debiao Li; Anthony G Christodoulou
Journal:  Magn Reson Med       Date:  2018-11-19       Impact factor: 4.668

8.  Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart.

Authors:  Daniel R Messroghli; Aleksandra Radjenovic; Sebastian Kozerke; David M Higgins; Mohan U Sivananthan; John P Ridgway
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

9.  Noncontrast myocardial T1 mapping using cardiovascular magnetic resonance for iron overload.

Authors:  Daniel M Sado; Viviana Maestrini; Stefan K Piechnik; Sanjay M Banypersad; Steven K White; Andrew S Flett; Matthew D Robson; Stefan Neubauer; Cono Ariti; Andrew Arai; Peter Kellman; Jin Yamamura; Bjoern P Schoennagel; Farrukh Shah; Bernard Davis; Sara Trompeter; Malcolm Walker; John Porter; James C Moon
Journal:  J Magn Reson Imaging       Date:  2014-08-08       Impact factor: 4.813

10.  Accuracy, precision, and reproducibility of four T1 mapping sequences: a head-to-head comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE.

Authors:  Sébastien Roujol; Sebastian Weingärtner; Murilo Foppa; Kelvin Chow; Keigo Kawaji; Long H Ngo; Peter Kellman; Warren J Manning; Richard B Thompson; Reza Nezafat
Journal:  Radiology       Date:  2014-04-04       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.