Shuang Wang1,2, Pu Bai1, Magdalena Ola Cichocka3, Jung Cho3, Tom Willhammar3, Yunzheng Wang1, Wenfu Yan1, Xiaodong Zou3, Jihong Yu1,4. 1. State Key Laboratory of Inorganic Synthesis and Preparative Chemistry, College of Chemistry, Jilin University, 2699 Qianjin Street, Changchun 130012, P. R. China. 2. College of Chemistry and Chemical Engineering, Henan Province Function-Oriented Porous Materials Key Laboratory, Luoyang Normal University, 6 Jiqing Road, Luoyang 471934, P.R. China. 3. Department of Materials and Environmental Chemistry, Stockholm University, Stockholm SE-106 91, Sweden. 4. International Center of Future Science, Jilin University, 2699 Qianjin Street, Changchun 130012, P.R. China.
Abstract
Water pollutants existing in their oxyanion forms have high solubility and environmental mobility. To capture these anionic pollutants, cost-effective inorganic materials with cationic frameworks and outstanding removal performance are ideal adsorbents. Herein, we report that two-dimensional (2D) cationic aluminoborate BAC(10) sets a new paradigm for highly selective and efficient capture of Cr(VI) and other oxyanions from aqueous solution. The structure of Cr(VI)-exchanged BAC(10) sample (Cr(VI)@BAC(10), H0.22·Al2BO4.3·(HCrO4)0.22·2.64H2O) has been successfully solved by continuous rotation electron diffraction. The crystallographic data show that the 2D cationic layer of BAC(10) is built by AlO6 octahedra, BO4 tetrahedra, and BO3 triangles. Partial chromate ions exchanged with Cl- ions are located within the interlayer region, which are chemically bonded to the aluminoborate layer. BAC(10) shows faster adsorption kinetics compared to the commercial anion exchange resin (AER) and layered double hydroxides (LDHs), a higher maximum adsorption capacity of 139.1 mg/g than that of AER (62.77 mg/g), LDHs (81.43 mg/g), and a vast majority of cationic MOFs, and a much broader working pH range (2-10.5) than LDHs. Moreover, BAC(10) also shows excellent Cr(VI) oxyanion removal performance for a solution with a low concentration (1-10 mg/L), and the residual concentration can be reduced to below 0.05 mg/L of the WHO drinking water criterion. These superior properties indicate that BAC(10) is a promising material for remediation of Cr(VI) and other harmful oxyanions from wastewater.
Water pollutants existing in their oxyanion forms have high solubility and environmental mobility. To capture these anionic pollutants, cost-effective inorganic materials with cationic frameworks and outstanding removal performance are ideal adsorbents. Herein, we report that two-dimensional (2D) cationic aluminoborate BAC(10) sets a new paradigm for highly selective and efficient capture of Cr(VI) and other oxyanions from aqueous solution. The structure of Cr(VI)-exchanged BAC(10) sample (Cr(VI)@BAC(10), H0.22·Al2BO4.3·(HCrO4)0.22·2.64H2O) has been successfully solved by continuous rotation electron diffraction. The crystallographic data show that the 2D cationic layer of BAC(10) is built by AlO6 octahedra, BO4 tetrahedra, and BO3 triangles. Partial chromate ions exchanged with Cl- ions are located within the interlayer region, which are chemically bonded to the aluminoborate layer. BAC(10) shows faster adsorption kinetics compared to the commercial anion exchange resin (AER) and layered double hydroxides (LDHs), a higher maximum adsorption capacity of 139.1 mg/g than that of AER (62.77 mg/g), LDHs (81.43 mg/g), and a vast majority of cationic MOFs, and a much broader working pH range (2-10.5) than LDHs. Moreover, BAC(10) also shows excellent Cr(VI) oxyanion removal performance for a solution with a low concentration (1-10 mg/L), and the residual concentration can be reduced to below 0.05 mg/L of the WHO drinking water criterion. These superior properties indicate that BAC(10) is a promising material for remediation of Cr(VI) and other harmful oxyanions from wastewater.
Water scarcity and
quality degradation due to the contamination
of harmful ions have become a worldwide crisis in the 21st century,
and thus there is an urgent demand to remove trace contaminants of
harmful ions from polluted water. A large number of water-soluble
ionic contaminants inherently exist in their oxyanion forms, such
as CrO42–, TcO4–, SeO42–, MoO42–, VO43–, PO43–, and AsO43–.[1,2] Compared
to the cationic pollutants that can be easily removed by adsorption
or precipitation,[3] oxyanions have higher
solubility and mobility and transfer easily in the environment because
the surface of soil or mineral is usually negatively charged due to
its low isoelectric point, which makes the oxyanions often poorly
sorbed.[4]Among the harmful oxyanions,
Cr(VI) has been identified as one
of the 17 chemicals posing the greatest threat to humans and has also
been included in the group A of human carcinogens due to its carcinogenicity,
mutagenicity, and mobility.[5] According
to the regulations of the World Health Organization (WHO), the highest
level of total Cr allowed in drinking water is 0.05 mg/L, which has
been adopted by European Union and China.[6−8] To meet such
a strict criterion, methods for the efficient removal of Cr(VI) from
aqueous environmental systems are highly needed.So far, several
methods for removal of Cr(VI) and other oxyanion
pollutants from aqueous solution have been reported, including chemical
precipitation,[9] adsorption,[10] photocatalytic reduction,[11] and membrane filtration.[12] However,
most of these methods have the disadvantages of high costs, complicated
operating processes, or low removal efficiencies, especially at low
concentrations of Cr(VI). Compared to these methods, anion exchange
is considered as a cost-effective, simple, and highly efficient method
for removal of oxyanion pollutants at low levels and point-of-use
applications.[13−15]Significant efforts have been made in the past
two decades to prepare
anion exchangers for removal of oxyanion pollutants.[16−19] Anion exchange resins (AERs) with amino-functional groups are the
most commonly used anion exchangers and show good performance for
oxyanion removal.[20−22] However, they still face many challenges in practical
application because of the high cost and limited thermal and chemical
stability originating from their organic nature. Recently, cationic
metal–organic frameworks (MOFs) have been extensively investigated
and outstanding results have been obtained in the fields of oxyanion
pollutant removal and catalysis.[23−28] Nevertheless, the commercialization of MOFs is still hampered by
their high cost and limited stability in aqueous solution.To
address these shortcomings, a series of cationic inorganic frameworks
exhibiting enhanced thermal and hydrolytic stability has been prepared.[29,30] Notably, layered double hydroxides (LDHs) consisting of cationic
brucite-type layers charge balanced by interlayer anions have received
extensive attention as the next generation of inorganic anion exchangers.[31,32] LDHs have shown excellent removal efficiency for a variety of harmful
oxyanions including chromate,[33] phosphate,[34] arsenate,[35] and selenate.[36] However, high-temperature calcination (usually
at or above 450 °C) is usually required before their usage, which
is a heavy energy consumption process.[37] In addition, other disadvantages for LDHs include the slow adsorption
kinetics and poor selectivity, especially in the presence of bicarbonate
and carbonate.[38]In the past decade,
a series of hydroxides and fluorides of heavy
p-block metals that possess 2D cationic inorganic layers has also
been reported.[39−42] The interlayer anions can be exchanged, thus allowing for the removal
of oxyanion pollutants from a solution. Nevertheless, the heavy metal
nature of such layered materials limits their practical application.
Meanwhile, a series of layered rare-earth hydroxides with a 2D cationic
inorganic layer has also been synthesized in which Y2(OH)5Cl·1.5H2O has been used for removing SeO42– and SeO32– from aqueous solution.[43,44] However, the use of
lanthanides in large doses restricts their practical use. Notre Dame
thorium borate-1 (NDTB-1), the first three-dimensional (3D) inorganic
cationic extended framework, could selectively remove 99TcO4– from radioactive waste in the
presence of a large excess of competing anions.[45−47] However, the
radioactive nature of thorium in the cationic framework of NDTB-1
would seriously limit its further application. Thus, it is highly
desirable to seek stable and cost-effective materials with pure inorganic
cationic frameworks, high capacities, fast kinetics, and good selectivity
toward toxic oxyanions.Recently, we reported a new type of
layered cationic aluminum oxyhydroxide,
JU-111, which was hydrothermally synthesized with low-cost raw materials.[48] Such a 2D material exhibits extraordinary performance
for Cr(VI) removal even in the presence of a large excess of CO32– and has a broad working pH range, which
is promising for toxic metal oxyanion remediation.In our earlier
study, we synthesized aluminoborate with a pure
inorganic cationic framework, namely BAC(10) ([H0.4Al2BO4.5]Cl0.4·3H2O).[49] The cationic framework of BAC(10) is built up
from triangular BO3, tetrahedral BO4, and octahedra
AlO6 whose positive charges are balanced by Cl– anions. The water adsorption of 20 wt % BAC(10) is comparable to
that of zeolites, indicating the open-framework nature of BAC(10).
Thermogravimetric analysis–mass spectrometry (TGA–MS)
and titration analyses confirmed the existence of freely movable Cl– in the cationic framework of BAC(10), which can be
exchanged by Br–. This indicates that BAC(10) is
a promising candidate for Cr(VI) removal. Unfortunately, the structure
of BAC(10) is difficult to be solved due to the ultrathin sheet-like
morphology of the material.In this context, we made further
investigations on the structure
of BAC(10) and its capture ability for Cr(VI) from aqueous solution.
The structure of the Cr(VI)@BAC(10) sample could be successfully solved
by continuous rotation electron diffraction (cRED), a data collection
protocol of 3D electron diffraction including crystal tracking. The
adsorption kinetics, isotherm, selectivity, removal efficiency at
low concentrations, and reusability of Cr(VI) on BAC(10) were systematically
studied using a batch method. In addition, the removal efficiency
of other oxyanion pollutants such as ReO4–, MoO42–, SeO42–, H2PO4–, and VO43– was also investigated. The Cr(VI) oxyanion removal
ability of BAC(10) was compared with that of other types of commercial
cationic sorbents such as LDHs and AER, which clearly demonstrated
its advantages in terms of adsorption capacity and adsorption kinetics.
To the best of our knowledge, the 2D cationic framework aluminoborate
creates a new paradigm in the removal of harmful oxyanions from water,
which may open up new possibilities for its application in many other
aspects.
Results and Discussion
Synthesis and Characterization of BAC(10)
Highly crystalline
aluminoborate BAC(10) was hydrothermally synthesized from a mixture
of boric acid, anhydrous aluminum trichloride, and ammonium hydroxide
at 150 °C for 18 h. The detailed information on synthesis is
provided in the Supporting Information.Figure shows the
powder X-ray diffraction (PXRD) patterns of as-synthesized and calcined
BAC(10) at 150, 200, 250, and 300 °C for 2 h. As can be seen,
the intensity of the characteristic diffraction peaks of BAC(10) decreases
with the increase of heating temperature. When the heating temperature
reaches 300 °C, the strongest diffraction peak at 10.36°
(i.e., (020) according to the later structure solution) almost disappears,
indicating that the long-range ordering of BAC(10) has been almost
destroyed at 300 °C. As observed in Figure , the positions of most characteristic diffraction
peaks of BAC(10) shift to a higher angle during the heating process,
suggesting that the aluminoborate structure gradually shrinks during
heating. Interestingly, the structure of BAC(10) can be regenerated
by immersing the 300 °C calcined BAC(10) in deionized (DI) water,
0.01 M NaCl, or 0.01 M HCl solution, as shown by the PXRD patterns
in Figure . The recovery
process can be described as a “structural memory effect,”
which has been often observed in LDHs.[26] HCl solution gives the best recovery followed by NaCl solution and
DI water. Structure recovery in DI water indicates that the adsorbed
H2O molecules refill the void space after the removal of
guest species in BAC(10) by calcination; a better structure recovery
in NaCl solution implies that the resorption of Cl– strengthens the filling effect; the best structure recovery in HCl
solution suggests that the acidic environment will further facilitate
the repair of the damage in the long-range ordering of BAC(10) due
to dehydration at high temperatures.
Figure 1
Experimental PXRD patterns of as-synthesized,
calcined BAC(10)
at 150, 200, 250, and 300 °C for 2 h and the regenerated BAC(10)
(immersing calcined BAC(10) in DI water, 0.01 M NaCl, or 0.01 M HCl
solution for 24 h).
Experimental PXRD patterns of as-synthesized,
calcined BAC(10)
at 150, 200, 250, and 300 °C for 2 h and the regenerated BAC(10)
(immersing calcined BAC(10) in DI water, 0.01 M NaCl, or 0.01 M HCl
solution for 24 h).Scanning electron microscopy
(SEM, Figure a,b)
and low-magnification transmission electron
microscopy (TEM, Figure c,d) images of the as-synthesized BAC(10) show that the product consists
of aggregates of nanosheet-like hexagon-shaped crystals with a length
of 3–5 μm and a width of 0.5–1 μm, implying
that BAC(10) might have a layered structure or the growth along the
direction perpendicular to the sheet is significantly restrained.
The corresponding atomic force microscopy (AFM) image (Figure e) shows that the average thickness
of the nanosheet is about 4.5 nm. The energy-dispersive X-ray spectroscopy
(EDS) mapping profile clearly reveals that the as-synthesized BAC(10)
contains homogeneously distributed Al, B, O, and Cl elements (Figure f–i).
Figure 2
SEM (a,b),
TEM (c,d), and AFM (e) images of the as-synthesized
BAC(10); EDS mapping profiles of BAC(10) for Al (f), B (g), O (h),
and Cl (i).
SEM (a,b),
TEM (c,d), and AFM (e) images of the as-synthesized
BAC(10); EDS mapping profiles of BAC(10) for Al (f), B (g), O (h),
and Cl (i).
Physicochemical Properties
and Structural Analysis of Cr(VI)@BAC(10)
Anion exchange
experiments were conducted at 25 °C using a
batch sorption method, and the detailed information is provided in
the Supporting Information. Figure a shows the PXRD patterns of
BAC(10) before and after adsorption of Cr(VI), which is denoted as
Cr(VI)@BAC(10). PXRD data reveal that the main structure of BAC(10)
is retained after the adsorption of Cr(VI). However, the crystallinity
is obviously decreased. A TEM analysis on Cr(VI)@BAC(10) (Figure S1) reveals that the lamellar morphology
of BAC(10) is maintained after Cr(VI) adsorption. The EDS mapping
profiles of BAC(10) and Cr(VI)@BAC(10) also confirm that the adsorption
of Cr(VI) from aqueous solution follows an anion exchange process
of Cl– existing in the framework of BAC(10) (Figure S2). The Fourier transform infrared (FTIR)
spectrum of Cr(VI)@BAC(10) shows an adsorption peak at 921 cm–1 that is not present in the spectrum of BAC(10) (Figure b). This peak can
be assigned to the antisymmetric CrVIO3 stretching
vibration, confirming the incorporation of Cr(VI) anions inside the
structure of BAC(10).[50]Figure c shows the X-ray photoelectron
spectroscopy (XPS) spectra of BAC(10) and Cr(VI)@BAC(10). In Figure c, the peak from
element Cl (198.5 eV, Cl 2p) is clearly observed in the spectrum of
BAC(10). After Cr(VI) adsorption, the Cl 2p peak at 198.5 eV completely
disappears and a new Cr 2p peak at about 580 eV appears simultaneously. Figure d shows the high-resolution
XPS spectra of the Cr 2p region. Compared to K2CrO4, the Cr 2p peaks of Cr(VI)@BAC(10) are slightly blueshifted.
The spectra of Cr(VI)@BAC(10) have two main peaks, that is, Cr 2p1/2 (589.5 eV) and Cr 2p3/2 (579.7 eV), which correspond
to Cr(VI). The minor signals with binding energies of 586.5 and 576.9
eV are attributed to the trace amount of Cr(III) formed from the known
reduction effects under X-ray irradiation.[51] The TGA results show that the total weight loss of BAC(10) and Cr(VI)@BAC(10)
between 100 and 800 °C is 33.3 and 26.1%, respectively (Figure e). The TGA–MS
analysis on BAC(10) and Cr(VI)@BAC(10) (Figure f) shows that HCl is released from BAC(10)
at above 250 °C, and no detectable HCl is released from Cr(VI)@BAC(10)
at the entire temperature range. The nitrogen adsorption analysis
gives a BET surface area of 35.6 m2/g for Cr(VI)@BAC(10),
which is smaller than that of 59.3 m2/g for as-synthesized
BAC(10) (Figure S3), which is consistent
with the decrease in crystallinity after the adsorption of Cr(VI)
(Figure a). Combining
the above characterization results, it can be concluded that: (1)
the Cl– ions in the structure of BAC(10) are exchangeable;
(2) Cr(VI) anions are incorporated inside the framework of BAC(10)
via anion exchange; and (3) all Cl– ions can be
exchanged by Cr(VI) anions under such conditions.
Figure 3
PXRD (a), FTIR (b), and
XPS (c) results of BAC(10) and Cr(VI)@BAC(10);
(d) high-resolution Cr 2p1/2 and Cr 2p3/2 core-level
XPS spectra of Cr(VI)@BAC(10) and K2CrO4; TGA
(e) and TGA–MS (f) of BAC(10) and Cr(VI)@BAC(10).
PXRD (a), FTIR (b), and
XPS (c) results of BAC(10) and Cr(VI)@BAC(10);
(d) high-resolution Cr 2p1/2 and Cr 2p3/2 core-level
XPS spectra of Cr(VI)@BAC(10) and K2CrO4; TGA
(e) and TGA–MS (f) of BAC(10) and Cr(VI)@BAC(10).For inspection of the Cr(VI)@BAC(10) crystalline structure,
cRED
data were collected using a TEM (Figure S4). The 3D reciprocal lattice reconstructed from the cRED data using
the software RED[52] shows that Cr(VI)@BAC(10)
is monoclinic with the unit cell parameters a = 16.020(3)
Å, b = 16.910(3) Å, c =
16.390(3) Å, and β = 112.69(3)° (Figure ). Because the nanosheets,
which are perpendicular to the b-axis, have only
a few unit cells, weak diffuse streaks along the b*-axis were observed for most reflections (Figure S5). Despite this, the intensities of reflections could be
extracted from the cRED data. The aluminoborate structure Cr(VI)@BAC(10)
was solved by direct methods using the space group P21/n (No. 14), which is very complex with 62 (12
aluminum, 6 boron, and 44 oxygen) atoms in the asymmetric unit. Three
chromate ions were located from the difference Fourier maps, which
were subsequently refined to an occupancy of 0.77 (CrA), 0.32 (CrB),
and 0.24 (CrC). The refinement against the cRED data converged to R1 = 0.2769 for 2771 reflections with I > 2I(σ) and R1 = 0.2983
for all 3541 reflections [CCDC-2127099]. More details of structure
determination are described in the Supporting Information (Section 7, Table S1, and Figures S6,S7).
Figure 4
(a,b) 3D reciprocal
lattice of Cr(VI)@BAC(10) viewed along b*- and c*-axes, respectively. Only strong
reflections are shown. (c,d) 2D slices of h0l and hk0 of the 3D reciprocal lattice
in panel (b), respectively. The systematic absence could be deduced
as hkl, 0kl, hk0: none, h0l: h + l = 2n, and that along 0k0 could not be determined due to the preferred orientation
around the b*-axis. The possible space groups are
then Pn (No. 7), P2/n (No. 13), and P21/n (No. 14).
(a,b) 3D reciprocal
lattice of Cr(VI)@BAC(10) viewed along b*- and c*-axes, respectively. Only strong
reflections are shown. (c,d) 2D slices of h0l and hk0 of the 3D reciprocal lattice
in panel (b), respectively. The systematic absence could be deduced
as hkl, 0kl, hk0: none, h0l: h + l = 2n, and that along 0k0 could not be determined due to the preferred orientation
around the b*-axis. The possible space groups are
then Pn (No. 7), P2/n (No. 13), and P21/n (No. 14).The framework of Cr(VI)@BAC(10)
(H0.22·Al2BO4.3·(HCrO4)0.22·2.64H2O) has a cationic layered
structure, built by AlO6 octahedra, BO4 tetrahedra,
and BO3 triangles.
The AlO6 octahedra are linked by edge- or corner-sharing
to form a layer with exclusively six rings (Figure a). The six rings are decorated by either
BO3 or BO4. Three-coordinated boron atoms are
found in the six rings with only one or two corner-sharing AlO6 octahedra; each boron is coordinated to three edge-sharing
oxygen atoms. Tetrahedrally coordinated boron atoms are located in
the six rings with three corner-sharing AlO6 octahedral
pairs; each BO4 is connected to one edge-sharing and two
terminal oxygens in the AlO6 octahedral layer, with one
terminal oxygen pointing away from the layer (Figure a). There are two layers in each unit cell,
and the layers are sinusoidal along the c-axis (Figure b). Adjacent layers
are held together by hydrogen bonding and form one-dimensional channels
along the a-axis. The BO4 tetrahedra extend
toward the channel to serve as one of the chromate chemisorption sites.
Within the channels are found three chromate ions, which are chemically
bonded to the aluminoborate layer. One chromate ion (CrA, 77% occupancy)
is connected to an AlO6 octahedron (Figure c), one (CrB, 32%) to both an AlO6 octahedron and a BO4 tetrahedron, and the third chromate
ion (CrC, 24%) is connected to two AlO6 octahedra, which
are unusually formed during the ion-exchange process. The chromate
ions are further stabilized via hydrogen bonding to the framework.
There are in total 5.25 chromate ions per unit cell, which gives a
formula of H0.22·Al2BO4.3·(HCrO4)0.22·2.64H2O. The chromate ions
CrB and CrC are too close to each other and cannot exist simultaneously.
If these sites are fully occupied, they could accommodate eight chromate
ions. There are other sites with similar local environments as the
binding sites, CrA, CrB, and CrC, that may absorb additional chromate
ions (Figure a). With
the current cRED data, only three partially occupied chromate ion
sites are found.
Figure 5
Structure of Cr(VI)@BAC(10) viewed along (a) [010] and
(b) [100]
directions. Only one layer is shown in panel (a). A total of four
CrO4– binding sites are shown, of which
two are partially occupied (77 and 32%, respectively). The empty sites
are marked by bare oxygen atoms. (c) Connections of two chromates
CrA and CrB to the aluminoborate layer. The third chromate (CrC) is
not shown for clarity.
Structure of Cr(VI)@BAC(10) viewed along (a) [010] and
(b) [100]
directions. Only one layer is shown in panel (a). A total of four
CrO4– binding sites are shown, of which
two are partially occupied (77 and 32%, respectively). The empty sites
are marked by bare oxygen atoms. (c) Connections of two chromates
CrA and CrB to the aluminoborate layer. The third chromate (CrC) is
not shown for clarity.
Effect of pH on Cr(VI)
Adsorption
Hydrolytic stability
is important for the long-term usage of ion exchangers in aqueous
solution. Figure S8 shows the PXRD patterns
of BAC(10) immersed in solutions with various pH values for 24 h under
stirring, which indicates that BAC(10) has excellent hydrolytic stability
in solutions with the pH range from 2 to 10.5. When the pH reaches
12, obvious dissolution of BAC(10) and formation of crystalline Al(OH)3 (JCPDE card no. 20-0011) are observed. A further slight increase
in pH (pH = 12.5) leads to the complete dissolution of BAC(10) and
formation of highly crystalline Al(OH)3. These results
indicate that BAC(10) has excellent stability in acidic, neutral,
and mildly basic solutions.Figure shows the influence of the initial pH of
the solution on the removal efficiency of Cr(VI) and on the equilibrium
pH. When the initial pH is increased from 2 to 10.5, the removal efficiency
orderly decreases from 94.9 to 81.5% (initial concentration of Cr(VI):
50 mg/L and solid/liquid ratio: 2 g/L). Notably, the equilibrium pH
maintains in the range of 3.77 to 5.02 even though the initial pH
ranges from 2 to 10.5, demonstrating the excellent acidic/basic buffer
ability of BAC(10). This might be due to the exchange-in of OH– and exchange-out of Cl–. When the
initial pH rises to 12, a sharp decline in Cr(VI) removal efficiency
to 17.2% and a dramatic increase in the equilibrium pH to 10.95 are
observed. The optimal removal efficiency for Cr(VI) is 95.2% when
the initial solution pH is 3.
Figure 6
Influence of the initial pH on the removal efficiency
(red line,
left axis) and the corresponding equilibrium pH (blue line, right
axis). The initial concentration of Cr(VI) is 50 mg/L and the solid/liquid
ratio is 2 g/L.
Influence of the initial pH on the removal efficiency
(red line,
left axis) and the corresponding equilibrium pH (blue line, right
axis). The initial concentration of Cr(VI) is 50 mg/L and the solid/liquid
ratio is 2 g/L.In the solution containing Cr(VI),
the predominant species of Cr(VI)
is HCrO4– when the pH is less than 6.5
and CrO42– when the pH is greater than
6.5 (Figure S9).[53,54] For capturing one HCrO4– anion, BAC(10)
needs to release one Cl–, while two Cl– anions will be needed to capture one CrO42–. Therefore, more CrO42– content in
solution will lead to a lower removal efficiency. In this study, when
the initial pH is in the range of 2 to 10.5, the equilibrium pH is
in the range of 3.77 to 5.02, at which the Cr(VI) species mainly exists
in the form of HCrO4– (Figure S9). With the increase of pH, the removal efficiency
of Cr(VI) slightly decreases (Figure ), which is due to the competitive adsorption of more
OH– on BAC(10). Further increasing the initial pH
from 10.5 to 12 results in the dramatic increase of the equilibrium
pH from about 5.02 to 10.95 (Figure ) at which Cr(VI) exists mainly in the form of CrO42– (Figure S9). In addition, the crystallinity of BAC(10) decreases significantly
and Al(OH)3 starts to be formed at such pH (Figure S8). Thus, a sudden drop in Cr(VI) removal
efficiency is expected when the initial pH reaches 12. It has been
reported that cationic framework materials, such as metal oxides,[55] cationic MOFs,[56] LDHs,[4] and AERs,[20] have shown
strong dependence on the pH of solution for Cr(VI) removal and the
optimal pH for Cr(VI) adsorption of these materials is usually 3 to
5. Unlike these materials, BAC(10) exhibits a wide working pH range
from 2 to 10.5 and such a superior feature makes it promising in practical
applications for Cr(VI) capture.
Adsorption Kinetics and
Adsorption Isotherms of Cr(VI) on BAC(10)
The adsorption
kinetics of Cr(VI) on BAC(10) is presented in Figure a (initial concentration
of Cr(VI): 20 mg/L; solid/liquid ratio: 2 g/L; and initial pH: 3).
Meanwhile, we selected the commercial AER (IRN78) and a calcined layered
double hydroxide (CLDH) for comparison. As shown in Figure a, at the contact time of 10
min, the removal efficiency of BAC(10), IRN78, and CLDH is 66.9, 52.8,
and 29.9%, respectively. When the contact time is extended to 60 min,
the corresponding removal efficiency is increased to 97.4, 97.9, and
69.5%, respectively. On further extending the contact time, the removal
efficiency of BAC(10) and IRN78 becomes almost constant, indicating
that the adsorption equilibrium has been achieved at the contact time
of 60 min. However, the adsorption equilibrium of CLDH can only be
reached at the contact time of 150 min. The UV–vis spectra
were acquired to monitor the concentration of Cr(VI) in solution as
a function of the contact time of 0, 10, 20, 40, 60, and 90 min. As
shown in Figure b,
the intensity of the adsorption peak of Cr2O72– at 352 nm in the UV–vis spectra of Cr(VI)
in aqueous solution at various adsorption times quickly decreases
within only 10 min and does not show further decrease after 60 min,
suggesting that the anion-exchange process is completed. The inset
photographs of Figure b also show that the solution changes to colorless within 60 min,
indicating that BAC(10) has a fast adsorption rate for Cr(VI), which
is consistent with the adsorption kinetics results and UV–vis
analysis. Compared to the cationic MOFs, BAC(10) also exhibits an
advance in the removal rate. For example, more than 24 h are needed
for ABT·2ClO4[23] and 1-SO4,[24] two MOFs with the fastest adsorption
kinetics of Cr(VI), to reach the adsorption equilibrium. The fast
adsorption kinetics of BAC(10) makes it highly suitable for practical
applications.
Figure 7
(a) Adsorption kinetics of Cr(VI) on BAC(10), IRN78, and
CLDH.
(b) UV–vis spectra of Cr(VI) in aqueous solution at various
adsorption times by BAC(10). The inset shows the corresponding photographs.
(c) Linear fitting with a pseudo-first-order kinetic model for BAC(10).
(d) Linear fitting with a pseudo-second-order kinetic model for BAC(10).
(a) Adsorption kinetics of Cr(VI) on BAC(10), IRN78, and
CLDH.
(b) UV–vis spectra of Cr(VI) in aqueous solution at various
adsorption times by BAC(10). The inset shows the corresponding photographs.
(c) Linear fitting with a pseudo-first-order kinetic model for BAC(10).
(d) Linear fitting with a pseudo-second-order kinetic model for BAC(10).The adsorption kinetics of BAC(10) is fitted by
the linear pseudo-first-order
equation and linear pseudo-second-order equation (eqs S1 and S2), respectively. The kinetic parameters and the
correlation coefficients (R2) are calculated
on the basis of line regression (Figure c,d) and are listed in Table S2. The fitting plot with the pseudo-second-order model
shows a better linearity (R2 = 0.999)
compared to the pseudo-first-order model (R2 = 0.978), which confirms that the adsorption kinetics of BAC(10)
follows the pseudo-second-order model, that is, a chemical adsorption
process. The fitting plots in Figures S10, S11 and the data in Table S2 show that the
adsorption kinetics of IRN78 (R2 = 0.999)
and CLDH (R2 = 0.997) also follows the
pseudo-second-order model, which is consistent with the results previously
reported.[4,21]The adsorption isotherms of Cr(VI)
on BAC(10), CLDH, and IRN78
are illustrated in Figure a and the corresponding equilibrium pH values are plotted
in Figure b (initial
concentration of Cr(VI): 50–800 mg/L; solid/liquid ratio: 2
g/L; initial pH: 3; and contact time: 12 h under stirring). Both Langmuir
and Freundlich models (eqs S3 and S4) are
used to fit the experimental data and the results are presented in Figure c,d, respectively.
The adsorption parameters and the correlation coefficients (R2) on the basis of line regression (Figure c,d) are listed in Table S3. The fitting plots in Figure c,d and the data in Table S3 clearly show that the Langmuir model
provides a better description of the adsorption behavior of Cr(VI)
than the Freundlich model does, indicating a monolayer coverage of
Cr(VI) anions on the internal surface of BAC(10), CLDH, and IRN-78.
According to the Langmuir fitting, the maximum adsorption capacity
(qm) for Cr(VI) on BAC(10) is 139.1 mg/g,
which is much higher than those on CLDH (81.43 mg/g) and IRN78 (62.77
mg/g), consistent with the previously reported values for CLDH and
IRN78.[48,57]Table S4 summarizes
the maximum adsorption capacities for Cr(VI) adsorption on typical
anion exchangers such as cationic MOFs, LDHs, and AERs. Obviously,
the maximum adsorption capacity of Cr(VI) on BAC(10) has outperformed
most of them and is just less than that of MOFs of MOR-2.[58] The results in Figure b show that the equilibrium solutions containing
BAC(10) are acidic (pH = 4–4.5), while those containing CLDH
or IRN78 are basic (pH = 9.5–11.6) even though they have the
same initial pH of 3.0. As discussed above, the distribution of Cr(VI)
species is strongly affected by the solution pH. The Cr(VI) species
mainly exists in the form of CrO42– in
the basic medium (pH > 6.5) and thus the adsorption capacity of
the
anion exchanger will be seriously inhibited. This is an important
reason why BAC(10) has higher adsorption capacity for Cr(VI) than
IRN78 and CLDH.
Figure 8
(a) Adsorption isotherms of Cr(VI) on BAC(10), IRN78,
and CLDH;
(b) the corresponding equilibrium pH; and (c) Langmuir linear plots
and (d) Freundlich linear plots for adsorption isotherms of Cr(VI)
on BAC(10), IRN78, and CLDH.
(a) Adsorption isotherms of Cr(VI) on BAC(10), IRN78,
and CLDH;
(b) the corresponding equilibrium pH; and (c) Langmuir linear plots
and (d) Freundlich linear plots for adsorption isotherms of Cr(VI)
on BAC(10), IRN78, and CLDH.
Adsorption Selectivity, Removal Efficiency, and Recyclability
of BAC(10)
In addition to Cr(VI), polluted water usually
contains other types of anions such as Cl–, NO3–, HCO3–, and
CO32–. The existence of such anions apparently
has a negative influence on the removal of Cr(VI) due to competitive
adsorption. Hence, efficient removal of Cr(VI) from waste water is
still a great challenge in the presence of large excess of competing
anions. Here, we investigated the removal efficiency of BAC(10) on
Cr(VI) in the presence of competitive anions of NO3–, Br–, Cl–, HCO3–, F–, or CO32– at various concentrations and the results are
shown in Figure a.
The initial concentration of Cr(VI) is 20.8 mg/L (0.4 mM), and the
concentration of competitive anions is 0, 0.4, 2, 4, or 8 mM. The
solid/liquid ratio is 2 g/L. To exclude the interference of pH, all
the initial pH values are adjusted to 7. The results in Figure a show that the monovalent
anions of NO3–, Br–, Cl–, and HCO3– have
negligible influence on the removal efficiency of BAC(10) for Cr(VI)
even under 20 times (8 mM) excess dose. The removal efficiency only
decreases by 12.5% at the maximum even in the presence of 20 times
excess of F– (8 mM). Unlike monovalent anions, a
large amount of CO32– can adversely affect
the adsorption of Cr(VI) and the removal efficiency decreased by 20.8%
in the presence of 8 mM CO32– (20 times
excess). Although the presence of large excess of CO32– has a relative obviously negative influence on the
removal efficiency of BAC(10) for Cr(VI), it is still obviously superior
to many other anion exchangers, such as Ni/Mg/Al-LDHs[59] and UiO-66-NH2@silica.[60] This may be ascribed to the excellent acidic/basic buffer ability
of BAC(10) as described above. These results indicate that BAC(10)
can selectively capture Cr(VI) even in the presence of large excess
of competitive anions.
Figure 9
(a) Influence of competitive anions of NO3–, Br–, Cl–, HCO3–, F–, and CO32– on Cr(VI) removal by BAC(10); (b) removal efficiency
of BAC(10)
for Cr(VI) from aqueous solution prepared from DI water and tap water
at low concentrations; (c) five cycles of adsorption–desorption
of Cr(VI) on BAC(10); and (d) removal efficiency of ReO4–, MoO42–, SeO42–, H2PO4–, and VO43– by BAC(10).
(a) Influence of competitive anions of NO3–, Br–, Cl–, HCO3–, F–, and CO32– on Cr(VI) removal by BAC(10); (b) removal efficiency
of BAC(10)
for Cr(VI) from aqueous solution prepared from DI water and tap water
at low concentrations; (c) five cycles of adsorption–desorption
of Cr(VI) on BAC(10); and (d) removal efficiency of ReO4–, MoO42–, SeO42–, H2PO4–, and VO43– by BAC(10).Although many adsorbents have excellent adsorption capacity
for
Cr(VI), it is difficult to reduce moderate and trace levels of Cr(VI)
below the maximum allowable discharge standard defined by the WHO
(0.05 mg/L).[6]Figure b presents the residual Cr(VI) concentration
of the solution treated by BAC(10) with a solid/liquid ratio of 2
g/L. The initial concentration varied from 2.5 to 20 mg/L. The results
show that the residual Cr(VI) concentration of the solution is lower
than 0.05 mg/L after the treatment of BAC(10) if the initial concentration
of Cr(VI) does not exceed 10 mg/L, which is below the allowed safe
levels of WHO for drinking water as well as China and European Union.
These results demonstrate that BAC(10) has excellent removal efficiency
for low Cr(VI) concentration solutions, which makes it a promising
material in practical applications for deep treatment of Cr(VI)-contaminated
water. Combining the outstanding selectivity and depth removal performance
of BAC(10) for Cr(VI) and the physicochemical and structural properties
of Cr(VI)@BAC(10), we can conclude that the adsorption mechanism is
based on the following: (i) ion exchange as the main mechanism of
BAC(10) for Cr(VI) removal; (ii) formation of chemical bonds between
the partial chromate ions and the inorganic sheet; and (iii) electrostatic
interactions between the Cr(VI) anions and positively charged framework
of BAC(10).Furthermore, the recyclability of BAC(10) was investigated.
The
Cr(VI)@BAC(10) samples could be regenerated by a facile ion-exchange
process method in a NaCl solution (detailed information is provided
in the Supporting Information). Figure c shows the removal
efficiency of BAC(10) for Cr(VI) in five cycles of adsorption–desorption
process. After the first cycle, the removal efficiency decreases from
95.2 to 90.3%. Even at the fifth adsorption–desorption process,
the removal efficiency of 70.3% can still be reached. The PXRD patterns
of regenerated BAC(10) samples show that the structure is retained
after multiple cycles (Figure S12). The
decrease in removal efficiency with the increase in the number of
cycles might be due to the strong affinity and the formation of chemical
bonding between partial Cr(VI) and the framework of BAC(10), which
leads to the incomplete replacement of Cr(VI) anions with Cl– in the regeneration process. The EDS spectra and photographs of
the regenerated BAC(10) samples further demonstrate the existence
of undesorbed Cr(VI) in the regenerated BAC(10) (Figures S13, S14).In addition to Cr(VI), many pollutants
inherently exist in their
oxyanion forms, such as ReO4–, MoO42–, SeO42–,
H2PO4–, and VO43–. Among these oxyanions, ReO4– is employed as the surrogate of TcO4– (99Tc), which is a highly problematic radioactive
waste;[61] H2PO4– is one of the main causes for water eutrophication;
MoO42–, SeO42–, and VO43– are also harmful oxyanions
to human health.[62−64] The removal efficiency of BAC(10) for ReO4–, MoO42–, SeO42–, H2PO4–, and VO43– is shown in Figure d. The initial concentrations
of Re, Mo, Se, P, and V were 20 mg/L. The results show that the removal
efficiency of BAC(10) for MoO42–, SeO42–, H2PO4–, and VO43– is over 99%, while for ReO4–, it is relatively low (29.1%). The results
clearly show that BAC(10) also has excellent removal ability for MoO42–, SeO42–,
H2PO4–, and VO43–.
Conclusions
Highly crystalline aluminoborate
BAC(10) with a pure inorganic
2D cationic framework is hydrothermally synthesized with cost-effective
source materials, and the structure of chromate ion-exchanged BAC(10)
has been solved by cRED. The anion exchange property of BAC(10) for
Cr(VI) from aqueous solution is superior to the commercial anion resin
and LDHs with the maximum adsorption capacity and adsorption kinetics
of Cr(VI). Owing to the acidic/basic buffer ability, BAC(10) exhibits
a broad working pH range of 2–10.5 and excellent selectivity
for Cr(VI) even in the presence of large amounts of excessive competitive
anions. In addition, BAC(10) exhibits outstanding selectivity and
depth removal performance for Cr(VI). The investigation on structural
analysis and adsorption mechanism confirms that the removal of Cr(VI)
from aqueous solution is achieved via the anion exchange of HCrO4– with freely mobile Cl– inside the structure of BAC(10) and formation of chemical bonds
between the partial chromate ions and the inorganic sheet, which results
in excellent selectivity for Cr(VI). The excellent performance and
low cost make BAC(10) a promising material in wastewater treatment
for Cr(VI) removal. BAC(10) also exhibits excellent removal efficiency
for other harmful oxyanions such as MoO42–, SeO42–, H2PO4–, and VO43– from
aqueous solution. To further investigate the possibility of use of
BAC(10) in practical applications, we will conduct large-scale synthesis
of BAC(10) and manufacture it into macroscopic structures such as
granules, pellets, cylinders, or membranes to meet the requirement
for practical applications.
Authors: Lin Zhu; Linjuan Zhang; Jie Li; Duo Zhang; Lanhua Chen; Daopeng Sheng; Shitong Yang; Chengliang Xiao; Jianqiang Wang; Zhifang Chai; Thomas E Albrecht-Schmitt; Shuao Wang Journal: Environ Sci Technol Date: 2017-07-12 Impact factor: 9.028
Authors: Shuao Wang; Evgeny V Alekseev; Juan Diwu; William H Casey; Brian L Phillips; Wulf Depmeier; Thomas E Albrecht-Schmitt Journal: Angew Chem Int Ed Engl Date: 2010-02-01 Impact factor: 15.336