Literature DB >> 35907136

Is it feasible to measure intra-abdominal pressure using a balloon-tipped rectal catheter? Results of a validation study.

Anneleen S Staelens1,2, Ann Heymans2, Wilfried Gyselaers1,3, Manu L N G Malbrain4,5,6, Sigrid Christiaens2, Niels Van Regenmortel7.   

Abstract

The gold standard to measure intra-abdominal pressure (IAP) is intra-vesical measurement via the urinary bladder. However, this technique is restricted in ambulatory settings because of the risk of iatrogenic urinary tract infections. Rectal IAP measurements (IAPrect) may overcome these limitations, but requires validation. This validation study compares the IAPrect technique against gold standard intra-vesical IAP measurements (IAPves). IAPrect using an air-filled balloon catheter and IAPves using Foley Manometer Low Volume were measured simultaneously in sedated and ventilated patients. Measurements were performed twice in different positions (supine and HOB 45° elevated head of bed) and with an external abdominal pressure belt. Sixteen patients were included. Seven were not eligible for analysis due to unreliable IAPrect values. IAPrect was significantly higher than IAPves for all body positions (p < 0.01) and the correlation between IAPves and IAPrect was poor and not significant in each position (p ≥ 0.25, R2 < 0.6, Lin's CCC < 0.8, bias - 8.1 mmHg and precision of 5.6 mmHg with large limits of agreement between - 19 to 2.9 mmHg, high percentage error 67.3%, and low concordance 86.2%). Repeatability of IAPrect was not reliable (R = 0.539, p = 0.315). For both techniques, measurements with the external abdominal pressure belt were significantly higher compared to those without (p < 0.03). IAPrect has important shortcomings making IAP estimation using a rectal catheter unfeasible because the numbers cannot be trusted nor validated.
© 2022. The Author(s).

Entities:  

Keywords:  Abdominal hypertension; Intra-abdominal pressure; Intra-vesical measurement; Monitoring; Rectal measurement; Validation

Year:  2022        PMID: 35907136     DOI: 10.1007/s10877-022-00890-6

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   1.977


  5 in total

1.  The Intra-abdominal Pressure in Pregnancy.

Authors:  R H Paramore
Journal:  Proc R Soc Med       Date:  1913

2.  Direct measurement of intra-abdominal pressure in various conditions.

Authors:  A Shafik; A El-Sharkawy; W M Sharaf
Journal:  Eur J Surg       Date:  1997-12

Review 3.  Long-term implications of intra-abdominal hypertension and abdominal compartment syndrome: physical, mental, and financial.

Authors:  Michael L Cheatham; Karen Safcsak; Michael Sugrue
Journal:  Am Surg       Date:  2011-07       Impact factor: 0.688

Review 4.  A systematic review and individual patient data meta-analysis on intra-abdominal hypertension in critically ill patients: the wake-up project. World initiative on Abdominal Hypertension Epidemiology, a Unifying Project (WAKE-Up!).

Authors:  M L N G Malbrain; D Chiumello; B M Cesana; A Reintam Blaser; J Starkopf; M Sugrue; P Pelosi; P Severgnini; G Hernandez; N Brienza; A W Kirkpatrick; A Schachtrupp; J Kempchen; E Estenssoro; M G Vidal; I De Laet; B L De Keulenaer
Journal:  Minerva Anestesiol       Date:  2013-12-12       Impact factor: 3.051

5.  Death by Disimpaction: A Bradycardic Arrest Secondary to Rectal Manipulation.

Authors:  Christopher S Sampson; Cory M Shea
Journal:  Case Rep Emerg Med       Date:  2016-12-28
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.